xref: /illumos-gate/usr/src/cmd/fm/dicts/PCI.po (revision 756113e7)
17c478bd9Sstevel@tonic-gate#
205dd151bSStephen Hanson# Copyright 2009 Sun Microsystems, Inc.  All rights reserved.
37c478bd9Sstevel@tonic-gate# Use is subject to license terms.
47c478bd9Sstevel@tonic-gate#
57c478bd9Sstevel@tonic-gate# CDDL HEADER START
67c478bd9Sstevel@tonic-gate#
77c478bd9Sstevel@tonic-gate# The contents of this file are subject to the terms of the
800d0963fSdilpreet# Common Development and Distribution License (the "License").
900d0963fSdilpreet# You may not use this file except in compliance with the License.
107c478bd9Sstevel@tonic-gate#
117c478bd9Sstevel@tonic-gate# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
127c478bd9Sstevel@tonic-gate# or http://www.opensolaris.org/os/licensing.
137c478bd9Sstevel@tonic-gate# See the License for the specific language governing permissions
147c478bd9Sstevel@tonic-gate# and limitations under the License.
157c478bd9Sstevel@tonic-gate#
167c478bd9Sstevel@tonic-gate# When distributing Covered Code, include this CDDL HEADER in each
177c478bd9Sstevel@tonic-gate# file and include the License file at usr/src/OPENSOLARIS.LICENSE.
187c478bd9Sstevel@tonic-gate# If applicable, add the following below this CDDL HEADER, with the
197c478bd9Sstevel@tonic-gate# fields enclosed by brackets "[]" replaced with your own identifying
207c478bd9Sstevel@tonic-gate# information: Portions Copyright [yyyy] [name of copyright owner]
217c478bd9Sstevel@tonic-gate#
227c478bd9Sstevel@tonic-gate# CDDL HEADER END
237c478bd9Sstevel@tonic-gate#
2400d0963fSdilpreet# DO NOT EDIT -- this file is generated by the Event Registry.
2500d0963fSdilpreet#
267c478bd9Sstevel@tonic-gate#
277c478bd9Sstevel@tonic-gate# code: PCI-8000-0C
287c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver
297c478bd9Sstevel@tonic-gate#
307c478bd9Sstevel@tonic-gatemsgid "PCI-8000-0C.type"
317c478bd9Sstevel@tonic-gatemsgstr "Fault"
327c478bd9Sstevel@tonic-gatemsgid "PCI-8000-0C.severity"
337c478bd9Sstevel@tonic-gatemsgstr "Critical"
347c478bd9Sstevel@tonic-gatemsgid "PCI-8000-0C.description"
3500d0963fSdilpreetmsgstr "A problem was detected in the PCI controller software.  Refer to %s for more information."
367c478bd9Sstevel@tonic-gatemsgid "PCI-8000-0C.response"
3700d0963fSdilpreetmsgstr "One or more of device instances may be disabled."
387c478bd9Sstevel@tonic-gatemsgid "PCI-8000-0C.impact"
3900d0963fSdilpreetmsgstr "Loss of services provided by the device instances associated with this problem."
407c478bd9Sstevel@tonic-gatemsgid "PCI-8000-0C.action"
41*756113e7SDan McDonaldmsgstr "Ensure latest drivers and patches are installed.  Use fmdump -v -u <EVENT_ID> to identify the module/package, or contact your illumos distribution team for support."
427c478bd9Sstevel@tonic-gate#
437c478bd9Sstevel@tonic-gate# code: PCI-8000-1Q
447c478bd9Sstevel@tonic-gate# keys: fault.io.pci.bus
457c478bd9Sstevel@tonic-gate#
467c478bd9Sstevel@tonic-gatemsgid "PCI-8000-1Q.type"
477c478bd9Sstevel@tonic-gatemsgstr "Fault"
487c478bd9Sstevel@tonic-gatemsgid "PCI-8000-1Q.severity"
497c478bd9Sstevel@tonic-gatemsgstr "Critical"
507c478bd9Sstevel@tonic-gatemsgid "PCI-8000-1Q.description"
517c478bd9Sstevel@tonic-gatemsgstr "A problem was detected for a PCI bus.  Refer to %s for more information."
527c478bd9Sstevel@tonic-gatemsgid "PCI-8000-1Q.response"
5300d0963fSdilpreetmsgstr "One or more device instances may be disabled."
547c478bd9Sstevel@tonic-gatemsgid "PCI-8000-1Q.impact"
5500d0963fSdilpreetmsgstr "Loss of services provided by the device instances associated with this fault."
567c478bd9Sstevel@tonic-gatemsgid "PCI-8000-1Q.action"
57*756113e7SDan McDonaldmsgstr "Schedule a repair procedure to replace the affected device.  Use fmdump -v -u <EVENT_ID> to identify the device or contact your illumos distribution team for support."
587c478bd9Sstevel@tonic-gate#
597c478bd9Sstevel@tonic-gate# code: PCI-8000-24
607c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.pci.bus
617c478bd9Sstevel@tonic-gate#
627c478bd9Sstevel@tonic-gatemsgid "PCI-8000-24.type"
637c478bd9Sstevel@tonic-gatemsgstr "Fault"
647c478bd9Sstevel@tonic-gatemsgid "PCI-8000-24.severity"
657c478bd9Sstevel@tonic-gatemsgstr "Critical"
667c478bd9Sstevel@tonic-gatemsgid "PCI-8000-24.description"
6700d0963fSdilpreetmsgstr "The system has diagnosed a problem, the suspects include one or more \nPCI buses and one or more PCI controller drivers.  Refer to %s for more information."
687c478bd9Sstevel@tonic-gatemsgid "PCI-8000-24.response"
6900d0963fSdilpreetmsgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
707c478bd9Sstevel@tonic-gatemsgid "PCI-8000-24.impact"
7100d0963fSdilpreetmsgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
727c478bd9Sstevel@tonic-gatemsgid "PCI-8000-24.action"
7300d0963fSdilpreetmsgstr "Use fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s)or driver(s).\n\nCheck for patches to identified device drivers, schedule a repair for \nindicated hardware.\n"
747c478bd9Sstevel@tonic-gate#
757c478bd9Sstevel@tonic-gate# code: PCI-8000-3R
767c478bd9Sstevel@tonic-gate# keys: fault.io.pci.device
777c478bd9Sstevel@tonic-gate#
787c478bd9Sstevel@tonic-gatemsgid "PCI-8000-3R.type"
797c478bd9Sstevel@tonic-gatemsgstr "Fault"
807c478bd9Sstevel@tonic-gatemsgid "PCI-8000-3R.severity"
817c478bd9Sstevel@tonic-gatemsgstr "Critical"
827c478bd9Sstevel@tonic-gatemsgid "PCI-8000-3R.description"
8300d0963fSdilpreetmsgstr "The system has diagnosed a problem in one or more PCI buses or devices, \nbased on the error telemetry detected by the PCI subsystem.  Refer to %s for more information."
847c478bd9Sstevel@tonic-gatemsgid "PCI-8000-3R.response"
8500d0963fSdilpreetmsgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
867c478bd9Sstevel@tonic-gatemsgid "PCI-8000-3R.impact"
8700d0963fSdilpreetmsgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
887c478bd9Sstevel@tonic-gatemsgid "PCI-8000-3R.action"
8900d0963fSdilpreetmsgstr "Use fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).\n\nSchedule a repair procedure to replace the affected device."
907c478bd9Sstevel@tonic-gate#
917c478bd9Sstevel@tonic-gate# code: PCI-8000-42
927c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.pci.device
937c478bd9Sstevel@tonic-gate#
947c478bd9Sstevel@tonic-gatemsgid "PCI-8000-42.type"
957c478bd9Sstevel@tonic-gatemsgstr "Fault"
967c478bd9Sstevel@tonic-gatemsgid "PCI-8000-42.severity"
977c478bd9Sstevel@tonic-gatemsgstr "Critical"
987c478bd9Sstevel@tonic-gatemsgid "PCI-8000-42.description"
9900d0963fSdilpreetmsgstr "The system has diagnosed a problem, the suspects include one or more \nPCI buses and one or more PCI controller drivers.  Refer to %s for more information."
1007c478bd9Sstevel@tonic-gatemsgid "PCI-8000-42.response"
10100d0963fSdilpreetmsgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1027c478bd9Sstevel@tonic-gatemsgid "PCI-8000-42.impact"
10300d0963fSdilpreetmsgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1047c478bd9Sstevel@tonic-gatemsgid "PCI-8000-42.action"
10500d0963fSdilpreetmsgstr "Use fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s)or driver(s).\n\nCheck for patches to identified device drivers, schedule a repair for \nindicated hardware.\n"
1067c478bd9Sstevel@tonic-gate#
1077c478bd9Sstevel@tonic-gate# code: PCI-8000-5X
1087c478bd9Sstevel@tonic-gate# keys: fault.io.pci.bus fault.io.pci.device
1097c478bd9Sstevel@tonic-gate#
1107c478bd9Sstevel@tonic-gatemsgid "PCI-8000-5X.type"
1117c478bd9Sstevel@tonic-gatemsgstr "Fault"
1127c478bd9Sstevel@tonic-gatemsgid "PCI-8000-5X.severity"
1137c478bd9Sstevel@tonic-gatemsgstr "Critical"
1147c478bd9Sstevel@tonic-gatemsgid "PCI-8000-5X.description"
11500d0963fSdilpreetmsgstr "The system has diagnosed a problem in one or more PCI buses or devices, \nbased on the error telemetry detected by the PCI subsystem.  Refer to %s for more information."
1167c478bd9Sstevel@tonic-gatemsgid "PCI-8000-5X.response"
11700d0963fSdilpreetmsgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1187c478bd9Sstevel@tonic-gatemsgid "PCI-8000-5X.impact"
11900d0963fSdilpreetmsgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1207c478bd9Sstevel@tonic-gatemsgid "PCI-8000-5X.action"
12100d0963fSdilpreetmsgstr "Use fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).\n\nSchedule a repair procedure to replace the affected device."
1227c478bd9Sstevel@tonic-gate#
1237c478bd9Sstevel@tonic-gate# code: PCI-8000-6E
1247c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device
1257c478bd9Sstevel@tonic-gate#
1267c478bd9Sstevel@tonic-gatemsgid "PCI-8000-6E.type"
1277c478bd9Sstevel@tonic-gatemsgstr "Fault"
1287c478bd9Sstevel@tonic-gatemsgid "PCI-8000-6E.severity"
1297c478bd9Sstevel@tonic-gatemsgstr "Critical"
1307c478bd9Sstevel@tonic-gatemsgid "PCI-8000-6E.description"
13100d0963fSdilpreetmsgstr "The system has diagnosed a problem, the suspects include one or more \nPCI buses and one or more PCI controller drivers.  Refer to %s for more information."
1327c478bd9Sstevel@tonic-gatemsgid "PCI-8000-6E.response"
13300d0963fSdilpreetmsgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1347c478bd9Sstevel@tonic-gatemsgid "PCI-8000-6E.impact"
13500d0963fSdilpreetmsgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1367c478bd9Sstevel@tonic-gatemsgid "PCI-8000-6E.action"
13700d0963fSdilpreetmsgstr "Use fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s)or driver(s).\n\nCheck for patches to identified device drivers, schedule a repair for \nindicated hardware.\n"
13800d0963fSdilpreet#
13900d0963fSdilpreet# code: PCI-8000-7J
14000d0963fSdilpreet# keys: fault.io.pci.device-interr
14100d0963fSdilpreet#
14200d0963fSdilpreetmsgid "PCI-8000-7J.type"
14300d0963fSdilpreetmsgstr "Fault"
14400d0963fSdilpreetmsgid "PCI-8000-7J.severity"
14500d0963fSdilpreetmsgstr "Critical"
14600d0963fSdilpreetmsgid "PCI-8000-7J.description"
147b7d3956bSstephhmsgstr "An unrecoverable problem was detected for a PCI device.\n  Refer to %s for more information."
14800d0963fSdilpreetmsgid "PCI-8000-7J.response"
14900d0963fSdilpreetmsgstr "One or more device instances may be disabled\n"
15000d0963fSdilpreetmsgid "PCI-8000-7J.impact"
15100d0963fSdilpreetmsgstr "Possible loss of services provided by the device instances associated with this fault\n"
15200d0963fSdilpreetmsgid "PCI-8000-7J.action"
153*756113e7SDan McDonaldmsgstr "Schedule a repair procedure to replace the affected device.  Use fmadm faulty to identify the device or contact your illumos distribution team for support.\n"
15400d0963fSdilpreet#
15500d0963fSdilpreet# code: PCI-8000-8S
15600d0963fSdilpreet# keys: fault.io.pci.bus-linkerr fault.io.pci.device-interr
15700d0963fSdilpreet#
15800d0963fSdilpreetmsgid "PCI-8000-8S.type"
15900d0963fSdilpreetmsgstr "Fault"
16000d0963fSdilpreetmsgid "PCI-8000-8S.severity"
16100d0963fSdilpreetmsgstr "Critical"
16200d0963fSdilpreetmsgid "PCI-8000-8S.description"
163b7d3956bSstephhmsgstr "An unrecoverable problem has been detected on the specified bus or on the specified transmitting device.\n  Refer to %s for more information."
16400d0963fSdilpreetmsgid "PCI-8000-8S.response"
16500d0963fSdilpreetmsgstr "One or more device instances may be disabled\n"
16600d0963fSdilpreetmsgid "PCI-8000-8S.impact"
16700d0963fSdilpreetmsgstr "Possible loss of services provided by the device instances associated with this fault\n"
16800d0963fSdilpreetmsgid "PCI-8000-8S.action"
169*756113e7SDan McDonaldmsgstr "If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device.  Use fmadm faulty to identify the device and bus or contact your illumos distribution team for support.\n"
17000d0963fSdilpreet#
17100d0963fSdilpreet# code: PCI-8000-95
17200d0963fSdilpreet# keys: fault.io.pci.device-invreq fault.io.pci.device-noresp
17300d0963fSdilpreet#
17400d0963fSdilpreetmsgid "PCI-8000-95.type"
17500d0963fSdilpreetmsgstr "Fault"
17600d0963fSdilpreetmsgid "PCI-8000-95.severity"
177b7d3956bSstephhmsgstr "Major"
17800d0963fSdilpreetmsgid "PCI-8000-95.description"
17900d0963fSdilpreetmsgstr "Either the transmitting device sent an invalid request or the receiving device failed to respond.\n  Refer to %s for more information."
18000d0963fSdilpreetmsgid "PCI-8000-95.response"
18100d0963fSdilpreetmsgstr "One or more device instances may be disabled\n"
18200d0963fSdilpreetmsgid "PCI-8000-95.impact"
18300d0963fSdilpreetmsgstr "Possible loss of services provided by the device instances associated with this fault\n"
18400d0963fSdilpreetmsgid "PCI-8000-95.action"
185*756113e7SDan McDonaldmsgstr "Ensure that the latest drivers and patches are installed. If a plug-in card is involved check for badly-seated cards or bent pins.  Otherwise schedule a repair procedure to replace the affected device(s).  Use fmadm faulty to identify the devices or contact your illumos distribution team for support.\n"
18600d0963fSdilpreet#
18700d0963fSdilpreet# code: PCI-8000-AP
18800d0963fSdilpreet# keys: fault.io.pci.device-interr fault.io.pci.device-invreq
18900d0963fSdilpreet#
19000d0963fSdilpreetmsgid "PCI-8000-AP.type"
19100d0963fSdilpreetmsgstr "Fault"
19200d0963fSdilpreetmsgid "PCI-8000-AP.severity"
193b7d3956bSstephhmsgstr "Major"
19400d0963fSdilpreetmsgid "PCI-8000-AP.description"
19500d0963fSdilpreetmsgstr "Either the transmitting device sent an invalid request or the receiving device is reporting an internal fault.\n  Refer to %s for more information."
19600d0963fSdilpreetmsgid "PCI-8000-AP.response"
19700d0963fSdilpreetmsgstr "One or more device instances may be disabled\n"
19800d0963fSdilpreetmsgid "PCI-8000-AP.impact"
19900d0963fSdilpreetmsgstr "Possible loss of services provided by the device instances associated with this fault\n"
20000d0963fSdilpreetmsgid "PCI-8000-AP.action"
201*756113e7SDan McDonaldmsgstr "Ensure that the latest drivers and patches are installed.  Otherwise schedule a repair procedure to replace the affected device(s).  Use fmadm faulty to identify the devices or contact your illumos distribution team for support.\n"
20200d0963fSdilpreet#
20300d0963fSdilpreet# code: PCI-8000-CA
20400d0963fSdilpreet# keys: fault.io.pci.device-noresp
20500d0963fSdilpreet#
20600d0963fSdilpreetmsgid "PCI-8000-CA.type"
20700d0963fSdilpreetmsgstr "Fault"
20800d0963fSdilpreetmsgid "PCI-8000-CA.severity"
209b7d3956bSstephhmsgstr "Major"
21000d0963fSdilpreetmsgid "PCI-8000-CA.description"
2119dd0f810Scindimsgstr "A device is failing to respond\n  Refer to %s for more information."
21200d0963fSdilpreetmsgid "PCI-8000-CA.response"
21300d0963fSdilpreetmsgstr "One or more device instances may be disabled\n"
21400d0963fSdilpreetmsgid "PCI-8000-CA.impact"
21500d0963fSdilpreetmsgstr "Possible loss of services provided by the device instances associated with this fault\n"
21600d0963fSdilpreetmsgid "PCI-8000-CA.action"
217*756113e7SDan McDonaldmsgstr "Schedule a repair procedure to replace the affected device.  Use fmadm faulty to identify the device or contact your illumos distribution team for support.\n"
218b7d3956bSstephh#
219b7d3956bSstephh# code: PCI-8000-DH
220b7d3956bSstephh# keys: fault.io.pci.bus-linkerr-unaf fault.io.pci.device-interr-unaf
221b7d3956bSstephh#
222b7d3956bSstephhmsgid "PCI-8000-DH.type"
223b7d3956bSstephhmsgstr "Fault"
224b7d3956bSstephhmsgid "PCI-8000-DH.severity"
225b7d3956bSstephhmsgstr "Major"
226b7d3956bSstephhmsgid "PCI-8000-DH.description"
227b7d3956bSstephhmsgstr "Too many recovered bus faults have been detected, which indicates a problem with the specified bus or with the specified transmitting device. This may degrade into an unrecoverable fault.\n  Refer to %s for more information."
228b7d3956bSstephhmsgid "PCI-8000-DH.response"
229b7d3956bSstephhmsgstr "One or more device instances may be disabled\n"
230b7d3956bSstephhmsgid "PCI-8000-DH.impact"
231b7d3956bSstephhmsgstr "Possible loss of services provided by the device instances associated with this fault\n"
232b7d3956bSstephhmsgid "PCI-8000-DH.action"
233*756113e7SDan McDonaldmsgstr "If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device.  Use fmadm faulty to identify the device and bus or contact your illumos distribution team for support.\n"
234b7d3956bSstephh#
235b7d3956bSstephh# code: PCI-8000-ED
236b7d3956bSstephh# keys: fault.io.pci.device-interr-corr
237b7d3956bSstephh#
238b7d3956bSstephhmsgid "PCI-8000-ED.type"
239b7d3956bSstephhmsgstr "Fault"
240b7d3956bSstephhmsgid "PCI-8000-ED.severity"
241b7d3956bSstephhmsgstr "Major"
242b7d3956bSstephhmsgid "PCI-8000-ED.description"
243b7d3956bSstephhmsgstr "Too many recovered internal faults have been detected within the specified PCI device. This may degrade into a non-recoverable fault.\n  Refer to %s for more information."
244b7d3956bSstephhmsgid "PCI-8000-ED.response"
245b7d3956bSstephhmsgstr "One or more device instances may be disabled\n"
246b7d3956bSstephhmsgid "PCI-8000-ED.impact"
247b7d3956bSstephhmsgstr "Possible loss of services provided by the device instances associated with this fault\n"
248b7d3956bSstephhmsgid "PCI-8000-ED.action"
249*756113e7SDan McDonaldmsgstr "Schedule a repair procedure to replace the affected device.  Use fmadm faulty to identify the device or contact your illumos distribution team for support.\n"
250b7d3956bSstephh#
251b7d3956bSstephh# code: PCI-8000-FY
252b7d3956bSstephh# keys: fault.io.pci.bus-linkerr-deg fault.io.pci.device-interr-deg
253b7d3956bSstephh#
254b7d3956bSstephhmsgid "PCI-8000-FY.type"
255b7d3956bSstephhmsgstr "Fault"
256b7d3956bSstephhmsgid "PCI-8000-FY.severity"
257b7d3956bSstephhmsgstr "Major"
258b7d3956bSstephhmsgid "PCI-8000-FY.description"
259b7d3956bSstephhmsgstr "An unrecoverable problem has been detected on the specified bus or on the specified transmitting device, which has resulted in that device running in a degraded state.\n  Refer to %s for more information."
260b7d3956bSstephhmsgid "PCI-8000-FY.response"
261b7d3956bSstephhmsgstr "None\n"
262b7d3956bSstephhmsgid "PCI-8000-FY.impact"
263b7d3956bSstephhmsgstr "Degraded services provided by the device instances associated with this fault\n"
264b7d3956bSstephhmsgid "PCI-8000-FY.action"
265*756113e7SDan McDonaldmsgstr "If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device.  Use fmadm faulty to identify the device and bus or contact your illumos distribution team for support.\n"
266b7d3956bSstephh#
267b7d3956bSstephh# code: PCI-8000-G3
268b7d3956bSstephh# keys: fault.io.pci.device-interr-deg
269b7d3956bSstephh#
270b7d3956bSstephhmsgid "PCI-8000-G3.type"
271b7d3956bSstephhmsgstr "Fault"
272b7d3956bSstephhmsgid "PCI-8000-G3.severity"
273b7d3956bSstephhmsgstr "Major"
274b7d3956bSstephhmsgid "PCI-8000-G3.description"
275b7d3956bSstephhmsgstr "An unrecoverable problem was detected for a PCI device, which has resulted in that device running in a degraded state.\n  Refer to %s for more information."
276b7d3956bSstephhmsgid "PCI-8000-G3.response"
277b7d3956bSstephhmsgstr "None\n"
278b7d3956bSstephhmsgid "PCI-8000-G3.impact"
279b7d3956bSstephhmsgstr "Degraded services provided by the device instances associated with this fault\n"
280b7d3956bSstephhmsgid "PCI-8000-G3.action"
281*756113e7SDan McDonaldmsgstr "Schedule a repair procedure to replace the affected device.  Use fmadm faulty to identify the device or contact your illumos distribution team for support.\n"
28205dd151bSStephen Hanson#
28305dd151bSStephen Hanson# code: PCI-8000-HR
28405dd151bSStephen Hanson# keys: fault.io.pci.fw_corrupt
28505dd151bSStephen Hanson#
28605dd151bSStephen Hansonmsgid "PCI-8000-HR.type"
28705dd151bSStephen Hansonmsgstr "Fault"
28805dd151bSStephen Hansonmsgid "PCI-8000-HR.severity"
28905dd151bSStephen Hansonmsgstr "Major"
29005dd151bSStephen Hansonmsgid "PCI-8000-HR.description"
29105dd151bSStephen Hansonmsgstr "A firmware corruption was detected for a PCI device.\n  Refer to %s for more information."
29205dd151bSStephen Hansonmsgid "PCI-8000-HR.response"
29305dd151bSStephen Hansonmsgstr "One or more device instances may be disabled.\n"
29405dd151bSStephen Hansonmsgid "PCI-8000-HR.impact"
29505dd151bSStephen Hansonmsgstr "Degraded services provided by the device instances associated with this fault.\n"
29605dd151bSStephen Hansonmsgid "PCI-8000-HR.action"
297*756113e7SDan McDonaldmsgstr "Use fmadm faulty to identify the device and then update the firmware to the latest version or schedule a repair procedure to replace the affected device. Contact your illumos distribution team for further information.\n"
29805dd151bSStephen Hanson#
29905dd151bSStephen Hanson# code: PCI-8000-J4
30005dd151bSStephen Hanson# keys: fault.io.pci.fw_mismatch
30105dd151bSStephen Hanson#
30205dd151bSStephen Hansonmsgid "PCI-8000-J4.type"
30305dd151bSStephen Hansonmsgstr "Fault"
30405dd151bSStephen Hansonmsgid "PCI-8000-J4.severity"
30505dd151bSStephen Hansonmsgstr "Major"
30605dd151bSStephen Hansonmsgid "PCI-8000-J4.description"
30705dd151bSStephen Hansonmsgstr "A firmware version mismatch was detected for a PCI device.\n  Refer to %s for more information."
30805dd151bSStephen Hansonmsgid "PCI-8000-J4.response"
30905dd151bSStephen Hansonmsgstr "One or more device instances may be disabled.\n"
31005dd151bSStephen Hansonmsgid "PCI-8000-J4.impact"
31105dd151bSStephen Hansonmsgstr "Degraded services provided by the device instances associated with this fault.\n"
31205dd151bSStephen Hansonmsgid "PCI-8000-J4.action"
313*756113e7SDan McDonaldmsgstr "Use fmadm faulty to identify the device and then update the firmware to the latest version. Contact your illumos distribution team for further information.\n"