xref: /illumos-gate/usr/src/cmd/fm/dicts/NIC.po (revision 12eb87fb)
1*12eb87fbSAlex Wilson#
2*12eb87fbSAlex Wilson# Copyright 2020 the University of Queensland
3*12eb87fbSAlex Wilson# Use is subject to license terms.
4*12eb87fbSAlex Wilson#
5*12eb87fbSAlex Wilson# This file and its contents are supplied under the terms of the
6*12eb87fbSAlex Wilson# Common Development and Distribution License ("CDDL"), version 1.0.
7*12eb87fbSAlex Wilson# You may only use this file in accordance with the terms of version
8*12eb87fbSAlex Wilson# 1.0 of the CDDL.
9*12eb87fbSAlex Wilson#
10*12eb87fbSAlex Wilson# A full copy of the text of the CDDL should have accompanied this
11*12eb87fbSAlex Wilson# source.  A copy of the CDDL is also available via the Internet at
12*12eb87fbSAlex Wilson# http://www.illumos.org/license/CDDL.
13*12eb87fbSAlex Wilson#
14*12eb87fbSAlex Wilson
15*12eb87fbSAlex Wilson#
16*12eb87fbSAlex Wilson# code: NIC-8000-0Q
17*12eb87fbSAlex Wilson# keys: fault.io.nic.transceiver.notsupp
18*12eb87fbSAlex Wilson#
19*12eb87fbSAlex Wilsonmsgid "NIC-8000-0Q.type"
20*12eb87fbSAlex Wilsonmsgstr "Fault"
21*12eb87fbSAlex Wilsonmsgid "NIC-8000-0Q.severity"
22*12eb87fbSAlex Wilsonmsgstr "Critical"
23*12eb87fbSAlex Wilsonmsgid "NIC-8000-0Q.description"
24*12eb87fbSAlex Wilsonmsgstr "NIC transceiver module %<fault-list[0].resource.hc-specific.txr_index> (SFP/SFP+/QSFP+ etc.) in %<fault-list[0].resource.hc-specific.link-name> is of a type that is not supported. This may be due to an incompatible link type or speed. In some NICs, this may also be caused by enforcement of a vendor or part whitelist.\n\n  NIC data link: %<fault-list[0].resource.hc-specific.link-name> (%<fault-list[0].resource.hc-specific.primary-mac-address>)\n  Module vendor: %<fault-list[0].resource.hc-specific.vendor>\n  Module part: %<fault-list[0].resource.part>\n  Module serial: %<fault-list[0].resource.serial>\n\n  Refer to %s for more information."
25*12eb87fbSAlex Wilsonmsgid "NIC-8000-0Q.response"
26*12eb87fbSAlex Wilsonmsgstr "The transceiver module has been disabled, and the network data link associated with it (%<fault-list[0].resource.hc-specific.link-name>) has been marked as down.\n"
27*12eb87fbSAlex Wilsonmsgid "NIC-8000-0Q.impact"
28*12eb87fbSAlex Wilsonmsgstr "No network traffic will pass through the data link or network interfaces associated with this transceiver slot.\n"
29*12eb87fbSAlex Wilsonmsgid "NIC-8000-0Q.action"
30*12eb87fbSAlex Wilsonmsgstr "Replace the transceiver module with one of a supported type.\n"
31*12eb87fbSAlex Wilson
32*12eb87fbSAlex Wilson#
33*12eb87fbSAlex Wilson# code: NIC-8000-1C
34*12eb87fbSAlex Wilson# keys: fault.io.nic.transceiver.whitelist
35*12eb87fbSAlex Wilson#
36*12eb87fbSAlex Wilsonmsgid "NIC-8000-1C.type"
37*12eb87fbSAlex Wilsonmsgstr "Fault"
38*12eb87fbSAlex Wilsonmsgid "NIC-8000-1C.severity"
39*12eb87fbSAlex Wilsonmsgstr "Critical"
40*12eb87fbSAlex Wilsonmsgid "NIC-8000-1C.description"
41*12eb87fbSAlex Wilsonmsgstr "NIC transceiver module %<fault-list[0].resource.hc-specific.txr_index> (SFP/SFP+/QSFP+ etc.) in %<fault-list[0].resource.hc-specific.link-name> is of a type that is not allowed to be used with this NIC (due to a hardware-enforced vendor or part whitelist).\n\n  NIC data link: %<fault-list[0].resource.hc-specific.link-name> (%<fault-list[0].resource.hc-specific.primary-mac-address>)\n  Module vendor: %<fault-list[0].resource.hc-specific.vendor>\n  Module part: %<fault-list[0].resource.part>\n  Module serial: %<fault-list[0].resource.serial>\n\n  Refer to %s for more information."
42*12eb87fbSAlex Wilsonmsgid "NIC-8000-1C.response"
43*12eb87fbSAlex Wilsonmsgstr "The transceiver module has been disabled, and the network data link associated with it (%<fault-list[0].resource.hc-specific.link-name>) has been marked as down.\n"
44*12eb87fbSAlex Wilsonmsgid "NIC-8000-1C.impact"
45*12eb87fbSAlex Wilsonmsgstr "No network traffic will pass through the data link or network\ninterfaces associated with this transceiver slot.\n"
46*12eb87fbSAlex Wilsonmsgid "NIC-8000-1C.action"
47*12eb87fbSAlex Wilsonmsgstr "Replace the transceiver module with one of a supported type.\n"
48*12eb87fbSAlex Wilson
49*12eb87fbSAlex Wilson#
50*12eb87fbSAlex Wilson# code: NIC-8000-2R
51*12eb87fbSAlex Wilson# keys: fault.io.nic.transceiver.overtemp
52*12eb87fbSAlex Wilson#
53*12eb87fbSAlex Wilsonmsgid "NIC-8000-2R.type"
54*12eb87fbSAlex Wilsonmsgstr "Fault"
55*12eb87fbSAlex Wilsonmsgid "NIC-8000-2R.severity"
56*12eb87fbSAlex Wilsonmsgstr "Critical"
57*12eb87fbSAlex Wilsonmsgid "NIC-8000-2R.description"
58*12eb87fbSAlex Wilsonmsgstr "NIC transceiver module %<fault-list[0].resource.hc-specific.txr_index> (SFP/SFP+/QSFP+ etc.) in %<fault-list[0].resource.hc-specific.link-name> has overheated.\n\n  NIC data link: %<fault-list[0].resource.hc-specific.link-name> (%<fault-list[0].resource.hc-specific.primary-mac-address>)\n  Module vendor: %<fault-list[0].resource.hc-specific.vendor>\n  Module part: %<fault-list[0].resource.part>\n  Module serial: %<fault-list[0].resource.serial>\n\n  Refer to %s for more information."
59*12eb87fbSAlex Wilsonmsgid "NIC-8000-2R.response"
60*12eb87fbSAlex Wilsonmsgstr "The transceiver module has been disabled, and the network data link associated with it (%<fault-list[0].resource.hc-specific.link-name>) has been marked as down.\n"
61*12eb87fbSAlex Wilsonmsgid "NIC-8000-2R.impact"
62*12eb87fbSAlex Wilsonmsgstr "No network traffic will pass through the data link or network interfaces associated with this transceiver slot.\n"
63*12eb87fbSAlex Wilsonmsgid "NIC-8000-2R.action"
64*12eb87fbSAlex Wilsonmsgstr "Remove the transceiver module and check for adequate ventilation\nand cooling. Re-inserting the module after it has cooled will restore service.\n"
65*12eb87fbSAlex Wilson
66*12eb87fbSAlex Wilson#
67*12eb87fbSAlex Wilson# code: NIC-8000-34
68*12eb87fbSAlex Wilson# keys: fault.io.nic.transceiver.hwfail
69*12eb87fbSAlex Wilson#
70*12eb87fbSAlex Wilsonmsgid "NIC-8000-34.type"
71*12eb87fbSAlex Wilsonmsgstr "Fault"
72*12eb87fbSAlex Wilsonmsgid "NIC-8000-34.severity"
73*12eb87fbSAlex Wilsonmsgstr "Critical"
74*12eb87fbSAlex Wilsonmsgid "NIC-8000-34.description"
75*12eb87fbSAlex Wilsonmsgstr "NIC transceiver module %<fault-list[0].resource.hc-specific.txr_index> (SFP/SFP+/QSFP+ etc.) in %<fault-list[0].resource.hc-specific.link-name> has experienced a hardware failure.\n\n  NIC data link: %<fault-list[0].resource.hc-specific.link-name> (%<fault-list[0].resource.hc-specific.primary-mac-address>)\n  Module vendor: %<fault-list[0].resource.hc-specific.vendor>\n  Module part: %<fault-list[0].resource.part>\n  Module serial: %<fault-list[0].resource.serial>\n\n  Refer to %s for more information."
76*12eb87fbSAlex Wilsonmsgid "NIC-8000-34.response"
77*12eb87fbSAlex Wilsonmsgstr "The transceiver module has been disabled, and the network data link associated with it (%<fault-list[0].resource.hc-specific.link-name>) has been marked as down.\n"
78*12eb87fbSAlex Wilsonmsgid "NIC-8000-34.impact"
79*12eb87fbSAlex Wilsonmsgstr "No network traffic will pass through the data link or network\ninterfaces associated with this transceiver slot.\n"
80*12eb87fbSAlex Wilsonmsgid "NIC-8000-34.action"
81*12eb87fbSAlex Wilsonmsgstr "Remove and check the transceiver module, and consider replacing it.\n"
82*12eb87fbSAlex Wilson
83*12eb87fbSAlex Wilson#
84*12eb87fbSAlex Wilson# code: NIC-8000-4X
85*12eb87fbSAlex Wilson# keys: fault.io.nic.transceiver.unknown
86*12eb87fbSAlex Wilson#
87*12eb87fbSAlex Wilsonmsgid "NIC-8000-4X.type"
88*12eb87fbSAlex Wilsonmsgstr "Fault"
89*12eb87fbSAlex Wilsonmsgid "NIC-8000-4X.severity"
90*12eb87fbSAlex Wilsonmsgstr "Critical"
91*12eb87fbSAlex Wilsonmsgid "NIC-8000-4X.description"
92*12eb87fbSAlex Wilsonmsgstr "The slot for NIC transceiver module %<fault-list[0].resource.hc-specific.txr_index> (SFP/SFP+/QSFP+ etc.) in %<fault-list[0].resource.hc-specific.link-name> is occupied, but hardware did not find a valid transceiver in it.\n  Refer to %s for more information."
93*12eb87fbSAlex Wilsonmsgid "NIC-8000-4X.response"
94*12eb87fbSAlex Wilsonmsgstr "The transceiver module slot has been disabled, and the network data link associated with it (%<fault-list[0].resource.hc-specific.link-name>) has been marked as down.\n"
95*12eb87fbSAlex Wilsonmsgid "NIC-8000-4X.impact"
96*12eb87fbSAlex Wilsonmsgstr "No network traffic will pass through the data link or network\ninterfaces associated with this transceiver slot.\n"
97*12eb87fbSAlex Wilsonmsgid "NIC-8000-4X.action"
98*12eb87fbSAlex Wilsonmsgstr "Remove and check the transceiver module. It may be faulty,\ninserted incorrectly, or not of the correct type for the slot.\nIf problems persist, consider replacing the module.\n"