xref: /illumos-gate/usr/src/cmd/fm/dicts/FMD.po (revision bbf21555)
17c478bd9Sstevel@tonic-gate#
2f6e214c7SGavin Maltby# Copyright (c) 2010, Oracle and/or its affiliates. All rights reserved.
37c478bd9Sstevel@tonic-gate#
47c478bd9Sstevel@tonic-gate# CDDL HEADER START
57c478bd9Sstevel@tonic-gate#
67c478bd9Sstevel@tonic-gate# The contents of this file are subject to the terms of the
79dd0f810Scindi# Common Development and Distribution License (the "License").
89dd0f810Scindi# You may not use this file except in compliance with the License.
97c478bd9Sstevel@tonic-gate#
107c478bd9Sstevel@tonic-gate# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
117c478bd9Sstevel@tonic-gate# or http://www.opensolaris.org/os/licensing.
127c478bd9Sstevel@tonic-gate# See the License for the specific language governing permissions
137c478bd9Sstevel@tonic-gate# and limitations under the License.
147c478bd9Sstevel@tonic-gate#
157c478bd9Sstevel@tonic-gate# When distributing Covered Code, include this CDDL HEADER in each
167c478bd9Sstevel@tonic-gate# file and include the License file at usr/src/OPENSOLARIS.LICENSE.
177c478bd9Sstevel@tonic-gate# If applicable, add the following below this CDDL HEADER, with the
187c478bd9Sstevel@tonic-gate# fields enclosed by brackets "[]" replaced with your own identifying
197c478bd9Sstevel@tonic-gate# information: Portions Copyright [yyyy] [name of copyright owner]
207c478bd9Sstevel@tonic-gate#
217c478bd9Sstevel@tonic-gate# CDDL HEADER END
227c478bd9Sstevel@tonic-gate#
23f6e214c7SGavin Maltby
249dd0f810Scindi# DO NOT EDIT -- this file is generated by the Event Registry.
259dd0f810Scindi#
269dd0f810Scindi#
277c478bd9Sstevel@tonic-gate# General-purpose messages
287c478bd9Sstevel@tonic-gate#
297c478bd9Sstevel@tonic-gatemsgid "syslog-msgs-message-template"
301cf6ec7eSsuhamsgstr "SUNW-MSG-ID: %s, TYPE: %s, VER: 1, SEVERITY: %s\nEVENT-TIME: %s\nPLATFORM: %s, CSN: %s, HOSTNAME: %s\nSOURCE: %s, REV: %s\nEVENT-ID: %s\nDESC: %s\nAUTO-RESPONSE: %s\nIMPACT: %s\nREC-ACTION: %s\n"
317c478bd9Sstevel@tonic-gate#
327c478bd9Sstevel@tonic-gate# Fault-related messages
337c478bd9Sstevel@tonic-gate#
347c478bd9Sstevel@tonic-gate#
359dd0f810Scindi#
367c478bd9Sstevel@tonic-gate# code: FMD-8000-0W
377c478bd9Sstevel@tonic-gate# keys: defect.sunos.fmd.nosub
387c478bd9Sstevel@tonic-gate#
397c478bd9Sstevel@tonic-gatemsgid "FMD-8000-0W.type"
407c478bd9Sstevel@tonic-gatemsgstr "Defect"
417c478bd9Sstevel@tonic-gatemsgid "FMD-8000-0W.severity"
427c478bd9Sstevel@tonic-gatemsgstr "Minor"
437c478bd9Sstevel@tonic-gatemsgid "FMD-8000-0W.description"
44756113e7SDan McDonaldmsgstr "The illumos Fault Manager received an event from a component to which no automated diagnosis software is currently subscribed.  Refer to %s for more information."
457c478bd9Sstevel@tonic-gatemsgid "FMD-8000-0W.response"
46756113e7SDan McDonaldmsgstr "Error reports from the component will be logged for examination by your illumos distribution team."
477c478bd9Sstevel@tonic-gatemsgid "FMD-8000-0W.impact"
487c478bd9Sstevel@tonic-gatemsgstr "Automated diagnosis and response for these events will not occur."
497c478bd9Sstevel@tonic-gatemsgid "FMD-8000-0W.action"
50756113e7SDan McDonaldmsgstr "Ensure that fault management software is installed properly.  Contact your illumos distribution team for support."
517c478bd9Sstevel@tonic-gate#
527c478bd9Sstevel@tonic-gate# code: FMD-8000-11
537c478bd9Sstevel@tonic-gate# keys: defect.sunos.fmd.nodiagcode
547c478bd9Sstevel@tonic-gate#
557c478bd9Sstevel@tonic-gatemsgid "FMD-8000-11.type"
567c478bd9Sstevel@tonic-gatemsgstr "Defect"
577c478bd9Sstevel@tonic-gatemsgid "FMD-8000-11.severity"
587c478bd9Sstevel@tonic-gatemsgstr "Minor"
597c478bd9Sstevel@tonic-gatemsgid "FMD-8000-11.description"
60756113e7SDan McDonaldmsgstr "An illumos Fault Manager component generated a diagnosis for which no message summary exists.  Refer to %s for more information."
617c478bd9Sstevel@tonic-gatemsgid "FMD-8000-11.response"
62756113e7SDan McDonaldmsgstr "The diagnosis has been saved in the fault log for examination by your illumos distribution team."
637c478bd9Sstevel@tonic-gatemsgid "FMD-8000-11.impact"
64*bbf21555SRichard Lowemsgstr "The fault log will need to be manually examined using fmdump(8) in order to determine if any human response is required."
657c478bd9Sstevel@tonic-gatemsgid "FMD-8000-11.action"
66756113e7SDan McDonaldmsgstr "Use fmdump -v -u <EVENT-ID> to view the diagnosis result.  Ensure that fault management software is installed properly."
677c478bd9Sstevel@tonic-gate#
687c478bd9Sstevel@tonic-gate# code: FMD-8000-2K
697c478bd9Sstevel@tonic-gate# keys: defect.sunos.fmd.module
707c478bd9Sstevel@tonic-gate#
717c478bd9Sstevel@tonic-gatemsgid "FMD-8000-2K.type"
727c478bd9Sstevel@tonic-gatemsgstr "Defect"
737c478bd9Sstevel@tonic-gatemsgid "FMD-8000-2K.severity"
747c478bd9Sstevel@tonic-gatemsgstr "Minor"
757c478bd9Sstevel@tonic-gatemsgid "FMD-8000-2K.description"
76756113e7SDan McDonaldmsgstr "An illumos Fault Manager component has experienced an error that required the module to be disabled.  Refer to %s for more information."
777c478bd9Sstevel@tonic-gatemsgid "FMD-8000-2K.response"
787c478bd9Sstevel@tonic-gatemsgstr "The module has been disabled.  Events destined for the module will be saved for manual diagnosis."
797c478bd9Sstevel@tonic-gatemsgid "FMD-8000-2K.impact"
807c478bd9Sstevel@tonic-gatemsgstr "Automated diagnosis and response for subsequent events associated with this module will not occur."
817c478bd9Sstevel@tonic-gatemsgid "FMD-8000-2K.action"
827c478bd9Sstevel@tonic-gatemsgstr "Use fmdump -v -u <EVENT-ID> to locate the module.  Use fmadm reset <module> to reset the module."
837c478bd9Sstevel@tonic-gate#
847c478bd9Sstevel@tonic-gate# code: FMD-8000-3F
857c478bd9Sstevel@tonic-gate# keys: defect.sunos.fmd.config
867c478bd9Sstevel@tonic-gate#
877c478bd9Sstevel@tonic-gatemsgid "FMD-8000-3F.type"
887c478bd9Sstevel@tonic-gatemsgstr "Defect"
897c478bd9Sstevel@tonic-gatemsgid "FMD-8000-3F.severity"
907c478bd9Sstevel@tonic-gatemsgstr "Minor"
917c478bd9Sstevel@tonic-gatemsgid "FMD-8000-3F.description"
92756113e7SDan McDonaldmsgstr "An illumos Fault Manager component could not load due to an erroroneous configuration file.  Refer to %s for more information."
937c478bd9Sstevel@tonic-gatemsgid "FMD-8000-3F.response"
947c478bd9Sstevel@tonic-gatemsgstr "The module has been disabled.  Events destined for the module will be saved for manual diagnosis."
957c478bd9Sstevel@tonic-gatemsgid "FMD-8000-3F.impact"
967c478bd9Sstevel@tonic-gatemsgstr "Automated diagnosis and response for subsequent events associated with this module will not occur."
977c478bd9Sstevel@tonic-gatemsgid "FMD-8000-3F.action"
987c478bd9Sstevel@tonic-gatemsgstr "Use fmdump -v -u <EVENT-ID> to locate the module.  Use fmadm load <module> to load the module after repairing its configuration."
99627351e3Scy#
100627351e3Scy# code: FMD-8000-4M
101627351e3Scy# keys: list.repaired
102627351e3Scy#
103627351e3Scymsgid "FMD-8000-4M.type"
104627351e3Scymsgstr "Repair"
105627351e3Scymsgid "FMD-8000-4M.severity"
106627351e3Scymsgstr "Minor"
107627351e3Scymsgid "FMD-8000-4M.description"
10825c6ff4bSstephhmsgstr "All faults associated with an event id have been addressed.\n  Refer to %s for more information."
109627351e3Scymsgid "FMD-8000-4M.response"
110f6e214c7SGavin Maltbymsgstr "Some system components offlined because of the original fault may have been brought back online."
111627351e3Scymsgid "FMD-8000-4M.impact"
112f6e214c7SGavin Maltbymsgstr "Performance degradation of the system due to the original fault may have been recovered."
113627351e3Scymsgid "FMD-8000-4M.action"
114627351e3Scymsgstr "Use fmdump -v -u <EVENT-ID> to identify the repaired components."
11525c6ff4bSstephh#
11625c6ff4bSstephh# code: FMD-8000-58
11725c6ff4bSstephh# keys: list.updated
11825c6ff4bSstephh#
11925c6ff4bSstephhmsgid "FMD-8000-58.type"
12025c6ff4bSstephhmsgstr "Update"
12125c6ff4bSstephhmsgid "FMD-8000-58.severity"
12225c6ff4bSstephhmsgstr "Minor"
12325c6ff4bSstephhmsgid "FMD-8000-58.description"
12425c6ff4bSstephhmsgstr "Some faults associated with an event id have been addressed.\n  Refer to %s for more information."
12525c6ff4bSstephhmsgid "FMD-8000-58.response"
126f6e214c7SGavin Maltbymsgstr "Some system components offlined because of the original fault may have been brought back online."
12725c6ff4bSstephhmsgid "FMD-8000-58.impact"
128f6e214c7SGavin Maltbymsgstr "Performance degradation of the system due to the original fault may have been recovered."
12925c6ff4bSstephhmsgid "FMD-8000-58.action"
130f6e214c7SGavin Maltbymsgstr "Use fmadm faulty to identify the repaired components, and any suspects that still need to be repaired."
13125c6ff4bSstephh#
13225c6ff4bSstephh# code: FMD-8000-6U
13325c6ff4bSstephh# keys: list.resolved
13425c6ff4bSstephh#
13525c6ff4bSstephhmsgid "FMD-8000-6U.type"
13625c6ff4bSstephhmsgstr "Resolved"
13725c6ff4bSstephhmsgid "FMD-8000-6U.severity"
13825c6ff4bSstephhmsgstr "Minor"
13925c6ff4bSstephhmsgid "FMD-8000-6U.description"
14025c6ff4bSstephhmsgstr "All faults associated with an event id have been addressed.\n  Refer to %s for more information."
14125c6ff4bSstephhmsgid "FMD-8000-6U.response"
142f6e214c7SGavin Maltbymsgstr "All system components offlined because of the original fault have been brought back online."
14325c6ff4bSstephhmsgid "FMD-8000-6U.impact"
144f6e214c7SGavin Maltbymsgstr "Performance degradation of the system due to the original fault has been recovered."
14525c6ff4bSstephhmsgid "FMD-8000-6U.action"
146f6e214c7SGavin Maltbymsgstr "Use fmdump -v -u <EVENT-ID> to identify the repaired components."
147