xref: /illumos-gate/usr/src/cmd/fm/dicts/FMD.po (revision bbf21555)
1#
2# Copyright (c) 2010, Oracle and/or its affiliates. All rights reserved.
3#
4# CDDL HEADER START
5#
6# The contents of this file are subject to the terms of the
7# Common Development and Distribution License (the "License").
8# You may not use this file except in compliance with the License.
9#
10# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
11# or http://www.opensolaris.org/os/licensing.
12# See the License for the specific language governing permissions
13# and limitations under the License.
14#
15# When distributing Covered Code, include this CDDL HEADER in each
16# file and include the License file at usr/src/OPENSOLARIS.LICENSE.
17# If applicable, add the following below this CDDL HEADER, with the
18# fields enclosed by brackets "[]" replaced with your own identifying
19# information: Portions Copyright [yyyy] [name of copyright owner]
20#
21# CDDL HEADER END
22#
23
24# DO NOT EDIT -- this file is generated by the Event Registry.
25#
26#
27# General-purpose messages
28#
29msgid "syslog-msgs-message-template"
30msgstr "SUNW-MSG-ID: %s, TYPE: %s, VER: 1, SEVERITY: %s\nEVENT-TIME: %s\nPLATFORM: %s, CSN: %s, HOSTNAME: %s\nSOURCE: %s, REV: %s\nEVENT-ID: %s\nDESC: %s\nAUTO-RESPONSE: %s\nIMPACT: %s\nREC-ACTION: %s\n"
31#
32# Fault-related messages
33#
34#
35#
36# code: FMD-8000-0W
37# keys: defect.sunos.fmd.nosub
38#
39msgid "FMD-8000-0W.type"
40msgstr "Defect"
41msgid "FMD-8000-0W.severity"
42msgstr "Minor"
43msgid "FMD-8000-0W.description"
44msgstr "The illumos Fault Manager received an event from a component to which no automated diagnosis software is currently subscribed.  Refer to %s for more information."
45msgid "FMD-8000-0W.response"
46msgstr "Error reports from the component will be logged for examination by your illumos distribution team."
47msgid "FMD-8000-0W.impact"
48msgstr "Automated diagnosis and response for these events will not occur."
49msgid "FMD-8000-0W.action"
50msgstr "Ensure that fault management software is installed properly.  Contact your illumos distribution team for support."
51#
52# code: FMD-8000-11
53# keys: defect.sunos.fmd.nodiagcode
54#
55msgid "FMD-8000-11.type"
56msgstr "Defect"
57msgid "FMD-8000-11.severity"
58msgstr "Minor"
59msgid "FMD-8000-11.description"
60msgstr "An illumos Fault Manager component generated a diagnosis for which no message summary exists.  Refer to %s for more information."
61msgid "FMD-8000-11.response"
62msgstr "The diagnosis has been saved in the fault log for examination by your illumos distribution team."
63msgid "FMD-8000-11.impact"
64msgstr "The fault log will need to be manually examined using fmdump(8) in order to determine if any human response is required."
65msgid "FMD-8000-11.action"
66msgstr "Use fmdump -v -u <EVENT-ID> to view the diagnosis result.  Ensure that fault management software is installed properly."
67#
68# code: FMD-8000-2K
69# keys: defect.sunos.fmd.module
70#
71msgid "FMD-8000-2K.type"
72msgstr "Defect"
73msgid "FMD-8000-2K.severity"
74msgstr "Minor"
75msgid "FMD-8000-2K.description"
76msgstr "An illumos Fault Manager component has experienced an error that required the module to be disabled.  Refer to %s for more information."
77msgid "FMD-8000-2K.response"
78msgstr "The module has been disabled.  Events destined for the module will be saved for manual diagnosis."
79msgid "FMD-8000-2K.impact"
80msgstr "Automated diagnosis and response for subsequent events associated with this module will not occur."
81msgid "FMD-8000-2K.action"
82msgstr "Use fmdump -v -u <EVENT-ID> to locate the module.  Use fmadm reset <module> to reset the module."
83#
84# code: FMD-8000-3F
85# keys: defect.sunos.fmd.config
86#
87msgid "FMD-8000-3F.type"
88msgstr "Defect"
89msgid "FMD-8000-3F.severity"
90msgstr "Minor"
91msgid "FMD-8000-3F.description"
92msgstr "An illumos Fault Manager component could not load due to an erroroneous configuration file.  Refer to %s for more information."
93msgid "FMD-8000-3F.response"
94msgstr "The module has been disabled.  Events destined for the module will be saved for manual diagnosis."
95msgid "FMD-8000-3F.impact"
96msgstr "Automated diagnosis and response for subsequent events associated with this module will not occur."
97msgid "FMD-8000-3F.action"
98msgstr "Use fmdump -v -u <EVENT-ID> to locate the module.  Use fmadm load <module> to load the module after repairing its configuration."
99#
100# code: FMD-8000-4M
101# keys: list.repaired
102#
103msgid "FMD-8000-4M.type"
104msgstr "Repair"
105msgid "FMD-8000-4M.severity"
106msgstr "Minor"
107msgid "FMD-8000-4M.description"
108msgstr "All faults associated with an event id have been addressed.\n  Refer to %s for more information."
109msgid "FMD-8000-4M.response"
110msgstr "Some system components offlined because of the original fault may have been brought back online."
111msgid "FMD-8000-4M.impact"
112msgstr "Performance degradation of the system due to the original fault may have been recovered."
113msgid "FMD-8000-4M.action"
114msgstr "Use fmdump -v -u <EVENT-ID> to identify the repaired components."
115#
116# code: FMD-8000-58
117# keys: list.updated
118#
119msgid "FMD-8000-58.type"
120msgstr "Update"
121msgid "FMD-8000-58.severity"
122msgstr "Minor"
123msgid "FMD-8000-58.description"
124msgstr "Some faults associated with an event id have been addressed.\n  Refer to %s for more information."
125msgid "FMD-8000-58.response"
126msgstr "Some system components offlined because of the original fault may have been brought back online."
127msgid "FMD-8000-58.impact"
128msgstr "Performance degradation of the system due to the original fault may have been recovered."
129msgid "FMD-8000-58.action"
130msgstr "Use fmadm faulty to identify the repaired components, and any suspects that still need to be repaired."
131#
132# code: FMD-8000-6U
133# keys: list.resolved
134#
135msgid "FMD-8000-6U.type"
136msgstr "Resolved"
137msgid "FMD-8000-6U.severity"
138msgstr "Minor"
139msgid "FMD-8000-6U.description"
140msgstr "All faults associated with an event id have been addressed.\n  Refer to %s for more information."
141msgid "FMD-8000-6U.response"
142msgstr "All system components offlined because of the original fault have been brought back online."
143msgid "FMD-8000-6U.impact"
144msgstr "Performance degradation of the system due to the original fault has been recovered."
145msgid "FMD-8000-6U.action"
146msgstr "Use fmdump -v -u <EVENT-ID> to identify the repaired components."
147