1724365f7Ssethg# 29e1c849eSDavid Zhang - Sun Microsystems - Beijing China# Copyright 2008 Sun Microsystems, Inc. All rights reserved. 3724365f7Ssethg# Use is subject to license terms. 4*0244979bSAlek Pinchuk# Copyright 2016 Nexenta Systems, Inc. All rights reserved. 5724365f7Ssethg# 6724365f7Ssethg# CDDL HEADER START 7724365f7Ssethg# 8724365f7Ssethg# The contents of this file are subject to the terms of the 9724365f7Ssethg# Common Development and Distribution License (the "License"). 10724365f7Ssethg# You may not use this file except in compliance with the License. 11724365f7Ssethg# 12724365f7Ssethg# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE 13724365f7Ssethg# or http://www.opensolaris.org/os/licensing. 14724365f7Ssethg# See the License for the specific language governing permissions 15724365f7Ssethg# and limitations under the License. 16724365f7Ssethg# 17724365f7Ssethg# When distributing Covered Code, include this CDDL HEADER in each 18724365f7Ssethg# file and include the License file at usr/src/OPENSOLARIS.LICENSE. 19724365f7Ssethg# If applicable, add the following below this CDDL HEADER, with the 20724365f7Ssethg# fields enclosed by brackets "[]" replaced with your own identifying 21724365f7Ssethg# information: Portions Copyright [yyyy] [name of copyright owner] 22724365f7Ssethg# 23724365f7Ssethg# CDDL HEADER END 24724365f7Ssethg# 25724365f7Ssethg# 26724365f7Ssethg# DO NOT EDIT -- this file is generated by the Event Registry. 27724365f7Ssethg# 28724365f7Ssethg# 29724365f7Ssethg# code: DISK-8000-0X 30724365f7Ssethg# keys: fault.io.disk.predictive-failure 31724365f7Ssethg# 32724365f7Ssethgmsgid "DISK-8000-0X.type" 33724365f7Ssethgmsgstr "Fault" 34724365f7Ssethgmsgid "DISK-8000-0X.severity" 35724365f7Ssethgmsgstr "Major" 36724365f7Ssethgmsgid "DISK-8000-0X.description" 37724365f7Ssethgmsgstr "SMART health-monitoring firmware reported that a disk\nfailure is imminent.\n Refer to %s for more information." 38724365f7Ssethgmsgid "DISK-8000-0X.response" 39724365f7Ssethgmsgstr "None.\n" 40724365f7Ssethgmsgid "DISK-8000-0X.impact" 41724365f7Ssethgmsgstr "It is likely that the continued operation of\nthis disk will result in data loss.\n" 42724365f7Ssethgmsgid "DISK-8000-0X.action" 43724365f7Ssethgmsgstr "Schedule a repair procedure to replace the affected disk.\nUse fmdump -v -u <EVENT_ID> to identify the disk.\n" 44724365f7Ssethg# 45724365f7Ssethg# code: DISK-8000-12 46724365f7Ssethg# keys: fault.io.disk.over-temperature 47724365f7Ssethg# 48724365f7Ssethgmsgid "DISK-8000-12.type" 49724365f7Ssethgmsgstr "Fault" 50724365f7Ssethgmsgid "DISK-8000-12.severity" 51724365f7Ssethgmsgstr "Major" 52724365f7Ssethgmsgid "DISK-8000-12.description" 53724365f7Ssethgmsgstr "A disk's temperature exceeded the limits established by\nits manufacturer.\n Refer to %s for more information." 54724365f7Ssethgmsgid "DISK-8000-12.response" 55724365f7Ssethgmsgstr "None.\n" 56724365f7Ssethgmsgid "DISK-8000-12.impact" 57724365f7Ssethgmsgstr "Performance degradation is likely and continued disk operation\nbeyond the temperature threshold can result in disk\ndamage and potential data loss.\n" 58724365f7Ssethgmsgid "DISK-8000-12.action" 59724365f7Ssethgmsgstr "Ensure that the system is properly cooled, that all fans are\nfunctional, and that there are no obstructions of airflow to the affected\ndisk.\n" 60724365f7Ssethg# 61724365f7Ssethg# code: DISK-8000-2J 62724365f7Ssethg# keys: fault.io.disk.self-test-failure 63724365f7Ssethg# 64724365f7Ssethgmsgid "DISK-8000-2J.type" 65724365f7Ssethgmsgstr "Fault" 66724365f7Ssethgmsgid "DISK-8000-2J.severity" 67724365f7Ssethgmsgstr "Critical" 68724365f7Ssethgmsgid "DISK-8000-2J.description" 69724365f7Ssethgmsgstr "One or more disk self tests failed.\n Refer to %s for more information." 70724365f7Ssethgmsgid "DISK-8000-2J.response" 71724365f7Ssethgmsgstr "None.\n" 72724365f7Ssethgmsgid "DISK-8000-2J.impact" 73724365f7Ssethgmsgstr "The disk has failed.\n" 74724365f7Ssethgmsgid "DISK-8000-2J.action" 75724365f7Ssethgmsgstr "Schedule a repair procedure to replace the affected disk.\nUse fmdump -v -u <EVENT_ID> to identify the disk.\n" 769e1c849eSDavid Zhang - Sun Microsystems - Beijing China# 779e1c849eSDavid Zhang - Sun Microsystems - Beijing China# code: DISK-8000-3E 789e1c849eSDavid Zhang - Sun Microsystems - Beijing China# keys: fault.io.scsi.cmd.disk.dev.rqs.derr 799e1c849eSDavid Zhang - Sun Microsystems - Beijing China# 809e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgid "DISK-8000-3E.type" 819e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgstr "Fault" 829e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgid "DISK-8000-3E.severity" 839e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgstr "Critical" 849e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgid "DISK-8000-3E.description" 859e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgstr "A non-recoverable hardware failure was detected by the device while performing a command.\n Refer to %s for more information." 869e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgid "DISK-8000-3E.response" 879e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgstr "The device may be offlined or degraded.\n" 889e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgid "DISK-8000-3E.impact" 899e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgstr "The device has failed. The service may have been lost or degraded.\n" 909e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgid "DISK-8000-3E.action" 919e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgstr "Ensure that the latest drivers and patches are installed. Schedule a repair procedure to replace the affected\ndevice. Use 'fmadm faulty' to find the affected disk.\n" 929e1c849eSDavid Zhang - Sun Microsystems - Beijing China# 939e1c849eSDavid Zhang - Sun Microsystems - Beijing China# code: DISK-8000-4Q 949e1c849eSDavid Zhang - Sun Microsystems - Beijing China# keys: fault.io.scsi.cmd.disk.dev.rqs.merr 959e1c849eSDavid Zhang - Sun Microsystems - Beijing China# 969e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgid "DISK-8000-4Q.type" 979e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgstr "Fault" 989e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgid "DISK-8000-4Q.severity" 999e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgstr "Critical" 1009e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgid "DISK-8000-4Q.description" 1019e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgstr "The command was terminated with a non-recovered error condition that may have been caused by a flaw in the media or an error in the recorded data. \n Refer to %s for more information." 1029e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgid "DISK-8000-4Q.response" 1039e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgstr "The device may be offlined or degraded.\n" 1049e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgid "DISK-8000-4Q.impact" 1059e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgstr "It is likely that continued operation will result in data corruption, which may eventually cause the loss of service or the service degradation.\n" 1069e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgid "DISK-8000-4Q.action" 1079e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgstr "Schedule a repair procedure to replace the affected device. Use 'fmadm faulty' to find the affected disk.\n" 108*0244979bSAlek Pinchuk# 109*0244979bSAlek Pinchuk# code: DISK-8000-8D 110*0244979bSAlek Pinchuk# keys: fault.io.disk.ssm-wearout 111*0244979bSAlek Pinchuk# 112*0244979bSAlek Pinchukmsgid "DISK-8000-8D.type" 113*0244979bSAlek Pinchukmsgstr "Fault" 114*0244979bSAlek Pinchukmsgid "DISK-8000-8D.severity" 115*0244979bSAlek Pinchukmsgstr "Major" 116*0244979bSAlek Pinchukmsgid "DISK-8000-8D.description" 117*0244979bSAlek Pinchukmsgstr "A solid state media device is nearing end of life as projected by the manufacturer." 118*0244979bSAlek Pinchukmsgid "DISK-8000-8D.response" 119*0244979bSAlek Pinchukmsgstr "None." 120*0244979bSAlek Pinchukmsgid "DISK-8000-8D.impact" 121*0244979bSAlek Pinchukmsgstr "Performance degradation is likely and continued operation of this device will cause drive failure and potential data loss." 122*0244979bSAlek Pinchukmsgid "DISK-8000-8D.action" 123*0244979bSAlek Pinchukmsgstr "Schedule a repair procedure to replace the affected drive.\nUse fmdump -V -u <EVENT_ID> to identify the drive." 124