xref: /illumos-gate/usr/src/cmd/fm/dicts/DISK.po (revision 0244979b)
1724365f7Ssethg#
29e1c849eSDavid Zhang - Sun Microsystems - Beijing China# Copyright 2008 Sun Microsystems, Inc.  All rights reserved.
3724365f7Ssethg# Use is subject to license terms.
4*0244979bSAlek Pinchuk# Copyright 2016 Nexenta Systems, Inc.  All rights reserved.
5724365f7Ssethg#
6724365f7Ssethg# CDDL HEADER START
7724365f7Ssethg#
8724365f7Ssethg# The contents of this file are subject to the terms of the
9724365f7Ssethg# Common Development and Distribution License (the "License").
10724365f7Ssethg# You may not use this file except in compliance with the License.
11724365f7Ssethg#
12724365f7Ssethg# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
13724365f7Ssethg# or http://www.opensolaris.org/os/licensing.
14724365f7Ssethg# See the License for the specific language governing permissions
15724365f7Ssethg# and limitations under the License.
16724365f7Ssethg#
17724365f7Ssethg# When distributing Covered Code, include this CDDL HEADER in each
18724365f7Ssethg# file and include the License file at usr/src/OPENSOLARIS.LICENSE.
19724365f7Ssethg# If applicable, add the following below this CDDL HEADER, with the
20724365f7Ssethg# fields enclosed by brackets "[]" replaced with your own identifying
21724365f7Ssethg# information: Portions Copyright [yyyy] [name of copyright owner]
22724365f7Ssethg#
23724365f7Ssethg# CDDL HEADER END
24724365f7Ssethg#
25724365f7Ssethg#
26724365f7Ssethg# DO NOT EDIT -- this file is generated by the Event Registry.
27724365f7Ssethg#
28724365f7Ssethg#
29724365f7Ssethg# code: DISK-8000-0X
30724365f7Ssethg# keys: fault.io.disk.predictive-failure
31724365f7Ssethg#
32724365f7Ssethgmsgid "DISK-8000-0X.type"
33724365f7Ssethgmsgstr "Fault"
34724365f7Ssethgmsgid "DISK-8000-0X.severity"
35724365f7Ssethgmsgstr "Major"
36724365f7Ssethgmsgid "DISK-8000-0X.description"
37724365f7Ssethgmsgstr "SMART health-monitoring firmware reported that a disk\nfailure is imminent.\n  Refer to %s for more information."
38724365f7Ssethgmsgid "DISK-8000-0X.response"
39724365f7Ssethgmsgstr "None.\n"
40724365f7Ssethgmsgid "DISK-8000-0X.impact"
41724365f7Ssethgmsgstr "It is likely that the continued operation of\nthis disk will result in data loss.\n"
42724365f7Ssethgmsgid "DISK-8000-0X.action"
43724365f7Ssethgmsgstr "Schedule a repair procedure to replace the affected disk.\nUse fmdump -v -u <EVENT_ID> to identify the disk.\n"
44724365f7Ssethg#
45724365f7Ssethg# code: DISK-8000-12
46724365f7Ssethg# keys: fault.io.disk.over-temperature
47724365f7Ssethg#
48724365f7Ssethgmsgid "DISK-8000-12.type"
49724365f7Ssethgmsgstr "Fault"
50724365f7Ssethgmsgid "DISK-8000-12.severity"
51724365f7Ssethgmsgstr "Major"
52724365f7Ssethgmsgid "DISK-8000-12.description"
53724365f7Ssethgmsgstr "A disk's temperature exceeded the limits established by\nits manufacturer.\n  Refer to %s for more information."
54724365f7Ssethgmsgid "DISK-8000-12.response"
55724365f7Ssethgmsgstr "None.\n"
56724365f7Ssethgmsgid "DISK-8000-12.impact"
57724365f7Ssethgmsgstr "Performance degradation is likely and continued disk operation\nbeyond the temperature threshold can result in disk\ndamage and potential data loss.\n"
58724365f7Ssethgmsgid "DISK-8000-12.action"
59724365f7Ssethgmsgstr "Ensure that the system is properly cooled, that all fans are\nfunctional, and that there are no obstructions of airflow to the affected\ndisk.\n"
60724365f7Ssethg#
61724365f7Ssethg# code: DISK-8000-2J
62724365f7Ssethg# keys: fault.io.disk.self-test-failure
63724365f7Ssethg#
64724365f7Ssethgmsgid "DISK-8000-2J.type"
65724365f7Ssethgmsgstr "Fault"
66724365f7Ssethgmsgid "DISK-8000-2J.severity"
67724365f7Ssethgmsgstr "Critical"
68724365f7Ssethgmsgid "DISK-8000-2J.description"
69724365f7Ssethgmsgstr "One or more disk self tests failed.\n  Refer to %s for more information."
70724365f7Ssethgmsgid "DISK-8000-2J.response"
71724365f7Ssethgmsgstr "None.\n"
72724365f7Ssethgmsgid "DISK-8000-2J.impact"
73724365f7Ssethgmsgstr "The disk has failed.\n"
74724365f7Ssethgmsgid "DISK-8000-2J.action"
75724365f7Ssethgmsgstr "Schedule a repair procedure to replace the affected disk.\nUse fmdump -v -u <EVENT_ID> to identify the disk.\n"
769e1c849eSDavid Zhang - Sun Microsystems - Beijing China#
779e1c849eSDavid Zhang - Sun Microsystems - Beijing China# code: DISK-8000-3E
789e1c849eSDavid Zhang - Sun Microsystems - Beijing China# keys: fault.io.scsi.cmd.disk.dev.rqs.derr
799e1c849eSDavid Zhang - Sun Microsystems - Beijing China#
809e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgid "DISK-8000-3E.type"
819e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgstr "Fault"
829e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgid "DISK-8000-3E.severity"
839e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgstr "Critical"
849e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgid "DISK-8000-3E.description"
859e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgstr "A non-recoverable hardware failure was detected by the device while performing a command.\n  Refer to %s for more information."
869e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgid "DISK-8000-3E.response"
879e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgstr "The device may be offlined or degraded.\n"
889e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgid "DISK-8000-3E.impact"
899e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgstr "The device has failed. The service may have been lost or degraded.\n"
909e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgid "DISK-8000-3E.action"
919e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgstr "Ensure that the latest drivers and patches are installed. Schedule a repair procedure to replace the affected\ndevice. Use 'fmadm faulty' to find the affected disk.\n"
929e1c849eSDavid Zhang - Sun Microsystems - Beijing China#
939e1c849eSDavid Zhang - Sun Microsystems - Beijing China# code: DISK-8000-4Q
949e1c849eSDavid Zhang - Sun Microsystems - Beijing China# keys: fault.io.scsi.cmd.disk.dev.rqs.merr
959e1c849eSDavid Zhang - Sun Microsystems - Beijing China#
969e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgid "DISK-8000-4Q.type"
979e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgstr "Fault"
989e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgid "DISK-8000-4Q.severity"
999e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgstr "Critical"
1009e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgid "DISK-8000-4Q.description"
1019e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgstr "The command was terminated with a non-recovered error condition that may have been caused by a flaw in the media or an error in the recorded data. \n  Refer to %s for more information."
1029e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgid "DISK-8000-4Q.response"
1039e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgstr "The device may be offlined or degraded.\n"
1049e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgid "DISK-8000-4Q.impact"
1059e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgstr "It is likely that continued operation will result in data corruption, which may eventually cause the loss of service or the service degradation.\n"
1069e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgid "DISK-8000-4Q.action"
1079e1c849eSDavid Zhang - Sun Microsystems - Beijing Chinamsgstr "Schedule a repair procedure to replace the affected device. Use 'fmadm faulty' to find the affected disk.\n"
108*0244979bSAlek Pinchuk#
109*0244979bSAlek Pinchuk# code: DISK-8000-8D
110*0244979bSAlek Pinchuk# keys: fault.io.disk.ssm-wearout
111*0244979bSAlek Pinchuk#
112*0244979bSAlek Pinchukmsgid "DISK-8000-8D.type"
113*0244979bSAlek Pinchukmsgstr "Fault"
114*0244979bSAlek Pinchukmsgid "DISK-8000-8D.severity"
115*0244979bSAlek Pinchukmsgstr "Major"
116*0244979bSAlek Pinchukmsgid "DISK-8000-8D.description"
117*0244979bSAlek Pinchukmsgstr "A solid state media device is nearing end of life as projected by the manufacturer."
118*0244979bSAlek Pinchukmsgid "DISK-8000-8D.response"
119*0244979bSAlek Pinchukmsgstr "None."
120*0244979bSAlek Pinchukmsgid "DISK-8000-8D.impact"
121*0244979bSAlek Pinchukmsgstr "Performance degradation is likely and continued operation of this device will cause drive failure and potential data loss."
122*0244979bSAlek Pinchukmsgid "DISK-8000-8D.action"
123*0244979bSAlek Pinchukmsgstr "Schedule a repair procedure to replace the affected drive.\nUse fmdump -V -u <EVENT_ID> to identify the drive."