# # Copyright 2009 Sun Microsystems, Inc. All rights reserved. # Use is subject to license terms. # # CDDL HEADER START # # The contents of this file are subject to the terms of the # Common Development and Distribution License (the "License"). # You may not use this file except in compliance with the License. # # You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE # or http://www.opensolaris.org/os/licensing. # See the License for the specific language governing permissions # and limitations under the License. # # When distributing Covered Code, include this CDDL HEADER in each # file and include the License file at usr/src/OPENSOLARIS.LICENSE. # If applicable, add the following below this CDDL HEADER, with the # fields enclosed by brackets "[]" replaced with your own identifying # information: Portions Copyright [yyyy] [name of copyright owner] # # CDDL HEADER END # # DO NOT EDIT -- this file is generated by the Event Registry. # # # code: PCI-8000-0C # keys: defect.io.pci.driver # msgid "PCI-8000-0C.type" msgstr "Fault" msgid "PCI-8000-0C.severity" msgstr "Critical" msgid "PCI-8000-0C.description" msgstr "A problem was detected in the PCI controller software. Refer to %s for more information." msgid "PCI-8000-0C.response" msgstr "One or more of device instances may be disabled." msgid "PCI-8000-0C.impact" msgstr "Loss of services provided by the device instances associated with this problem." msgid "PCI-8000-0C.action" msgstr "Ensure latest drivers and patches are installed. Use fmdump -v -u to identify the module/package, or contact your illumos distribution team for support." # # code: PCI-8000-1Q # keys: fault.io.pci.bus # msgid "PCI-8000-1Q.type" msgstr "Fault" msgid "PCI-8000-1Q.severity" msgstr "Critical" msgid "PCI-8000-1Q.description" msgstr "A problem was detected for a PCI bus. Refer to %s for more information." msgid "PCI-8000-1Q.response" msgstr "One or more device instances may be disabled." msgid "PCI-8000-1Q.impact" msgstr "Loss of services provided by the device instances associated with this fault." msgid "PCI-8000-1Q.action" msgstr "Schedule a repair procedure to replace the affected device. Use fmdump -v -u to identify the device or contact your illumos distribution team for support." # # code: PCI-8000-24 # keys: defect.io.pci.driver fault.io.pci.bus # msgid "PCI-8000-24.type" msgstr "Fault" msgid "PCI-8000-24.severity" msgstr "Critical" msgid "PCI-8000-24.description" msgstr "The system has diagnosed a problem, the suspects include one or more \nPCI buses and one or more PCI controller drivers. Refer to %s for more information." msgid "PCI-8000-24.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "PCI-8000-24.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "PCI-8000-24.action" msgstr "Use fmdump -v -u to identify the \nsuspected device(s)or driver(s).\n\nCheck for patches to identified device drivers, schedule a repair for \nindicated hardware.\n" # # code: PCI-8000-3R # keys: fault.io.pci.device # msgid "PCI-8000-3R.type" msgstr "Fault" msgid "PCI-8000-3R.severity" msgstr "Critical" msgid "PCI-8000-3R.description" msgstr "The system has diagnosed a problem in one or more PCI buses or devices, \nbased on the error telemetry detected by the PCI subsystem. Refer to %s for more information." msgid "PCI-8000-3R.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "PCI-8000-3R.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "PCI-8000-3R.action" msgstr "Use fmdump -v -u to identify the \nsuspected device(s).\n\nSchedule a repair procedure to replace the affected device." # # code: PCI-8000-42 # keys: defect.io.pci.driver fault.io.pci.device # msgid "PCI-8000-42.type" msgstr "Fault" msgid "PCI-8000-42.severity" msgstr "Critical" msgid "PCI-8000-42.description" msgstr "The system has diagnosed a problem, the suspects include one or more \nPCI buses and one or more PCI controller drivers. Refer to %s for more information." msgid "PCI-8000-42.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "PCI-8000-42.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "PCI-8000-42.action" msgstr "Use fmdump -v -u to identify the \nsuspected device(s)or driver(s).\n\nCheck for patches to identified device drivers, schedule a repair for \nindicated hardware.\n" # # code: PCI-8000-5X # keys: fault.io.pci.bus fault.io.pci.device # msgid "PCI-8000-5X.type" msgstr "Fault" msgid "PCI-8000-5X.severity" msgstr "Critical" msgid "PCI-8000-5X.description" msgstr "The system has diagnosed a problem in one or more PCI buses or devices, \nbased on the error telemetry detected by the PCI subsystem. Refer to %s for more information." msgid "PCI-8000-5X.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "PCI-8000-5X.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "PCI-8000-5X.action" msgstr "Use fmdump -v -u to identify the \nsuspected device(s).\n\nSchedule a repair procedure to replace the affected device." # # code: PCI-8000-6E # keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device # msgid "PCI-8000-6E.type" msgstr "Fault" msgid "PCI-8000-6E.severity" msgstr "Critical" msgid "PCI-8000-6E.description" msgstr "The system has diagnosed a problem, the suspects include one or more \nPCI buses and one or more PCI controller drivers. Refer to %s for more information." msgid "PCI-8000-6E.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "PCI-8000-6E.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "PCI-8000-6E.action" msgstr "Use fmdump -v -u to identify the \nsuspected device(s)or driver(s).\n\nCheck for patches to identified device drivers, schedule a repair for \nindicated hardware.\n" # # code: PCI-8000-7J # keys: fault.io.pci.device-interr # msgid "PCI-8000-7J.type" msgstr "Fault" msgid "PCI-8000-7J.severity" msgstr "Critical" msgid "PCI-8000-7J.description" msgstr "An unrecoverable problem was detected for a PCI device.\n Refer to %s for more information." msgid "PCI-8000-7J.response" msgstr "One or more device instances may be disabled\n" msgid "PCI-8000-7J.impact" msgstr "Possible loss of services provided by the device instances associated with this fault\n" msgid "PCI-8000-7J.action" msgstr "Schedule a repair procedure to replace the affected device. Use fmadm faulty to identify the device or contact your illumos distribution team for support.\n" # # code: PCI-8000-8S # keys: fault.io.pci.bus-linkerr fault.io.pci.device-interr # msgid "PCI-8000-8S.type" msgstr "Fault" msgid "PCI-8000-8S.severity" msgstr "Critical" msgid "PCI-8000-8S.description" msgstr "An unrecoverable problem has been detected on the specified bus or on the specified transmitting device.\n Refer to %s for more information." msgid "PCI-8000-8S.response" msgstr "One or more device instances may be disabled\n" msgid "PCI-8000-8S.impact" msgstr "Possible loss of services provided by the device instances associated with this fault\n" msgid "PCI-8000-8S.action" msgstr "If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device. Use fmadm faulty to identify the device and bus or contact your illumos distribution team for support.\n" # # code: PCI-8000-95 # keys: fault.io.pci.device-invreq fault.io.pci.device-noresp # msgid "PCI-8000-95.type" msgstr "Fault" msgid "PCI-8000-95.severity" msgstr "Major" msgid "PCI-8000-95.description" msgstr "Either the transmitting device sent an invalid request or the receiving device failed to respond.\n Refer to %s for more information." msgid "PCI-8000-95.response" msgstr "One or more device instances may be disabled\n" msgid "PCI-8000-95.impact" msgstr "Possible loss of services provided by the device instances associated with this fault\n" msgid "PCI-8000-95.action" msgstr "Ensure that the latest drivers and patches are installed. If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device(s). Use fmadm faulty to identify the devices or contact your illumos distribution team for support.\n" # # code: PCI-8000-AP # keys: fault.io.pci.device-interr fault.io.pci.device-invreq # msgid "PCI-8000-AP.type" msgstr "Fault" msgid "PCI-8000-AP.severity" msgstr "Major" msgid "PCI-8000-AP.description" msgstr "Either the transmitting device sent an invalid request or the receiving device is reporting an internal fault.\n Refer to %s for more information." msgid "PCI-8000-AP.response" msgstr "One or more device instances may be disabled\n" msgid "PCI-8000-AP.impact" msgstr "Possible loss of services provided by the device instances associated with this fault\n" msgid "PCI-8000-AP.action" msgstr "Ensure that the latest drivers and patches are installed. Otherwise schedule a repair procedure to replace the affected device(s). Use fmadm faulty to identify the devices or contact your illumos distribution team for support.\n" # # code: PCI-8000-CA # keys: fault.io.pci.device-noresp # msgid "PCI-8000-CA.type" msgstr "Fault" msgid "PCI-8000-CA.severity" msgstr "Major" msgid "PCI-8000-CA.description" msgstr "A device is failing to respond\n Refer to %s for more information." msgid "PCI-8000-CA.response" msgstr "One or more device instances may be disabled\n" msgid "PCI-8000-CA.impact" msgstr "Possible loss of services provided by the device instances associated with this fault\n" msgid "PCI-8000-CA.action" msgstr "Schedule a repair procedure to replace the affected device. Use fmadm faulty to identify the device or contact your illumos distribution team for support.\n" # # code: PCI-8000-DH # keys: fault.io.pci.bus-linkerr-unaf fault.io.pci.device-interr-unaf # msgid "PCI-8000-DH.type" msgstr "Fault" msgid "PCI-8000-DH.severity" msgstr "Major" msgid "PCI-8000-DH.description" msgstr "Too many recovered bus faults have been detected, which indicates a problem with the specified bus or with the specified transmitting device. This may degrade into an unrecoverable fault.\n Refer to %s for more information." msgid "PCI-8000-DH.response" msgstr "One or more device instances may be disabled\n" msgid "PCI-8000-DH.impact" msgstr "Possible loss of services provided by the device instances associated with this fault\n" msgid "PCI-8000-DH.action" msgstr "If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device. Use fmadm faulty to identify the device and bus or contact your illumos distribution team for support.\n" # # code: PCI-8000-ED # keys: fault.io.pci.device-interr-corr # msgid "PCI-8000-ED.type" msgstr "Fault" msgid "PCI-8000-ED.severity" msgstr "Major" msgid "PCI-8000-ED.description" msgstr "Too many recovered internal faults have been detected within the specified PCI device. This may degrade into a non-recoverable fault.\n Refer to %s for more information." msgid "PCI-8000-ED.response" msgstr "One or more device instances may be disabled\n" msgid "PCI-8000-ED.impact" msgstr "Possible loss of services provided by the device instances associated with this fault\n" msgid "PCI-8000-ED.action" msgstr "Schedule a repair procedure to replace the affected device. Use fmadm faulty to identify the device or contact your illumos distribution team for support.\n" # # code: PCI-8000-FY # keys: fault.io.pci.bus-linkerr-deg fault.io.pci.device-interr-deg # msgid "PCI-8000-FY.type" msgstr "Fault" msgid "PCI-8000-FY.severity" msgstr "Major" msgid "PCI-8000-FY.description" msgstr "An unrecoverable problem has been detected on the specified bus or on the specified transmitting device, which has resulted in that device running in a degraded state.\n Refer to %s for more information." msgid "PCI-8000-FY.response" msgstr "None\n" msgid "PCI-8000-FY.impact" msgstr "Degraded services provided by the device instances associated with this fault\n" msgid "PCI-8000-FY.action" msgstr "If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device. Use fmadm faulty to identify the device and bus or contact your illumos distribution team for support.\n" # # code: PCI-8000-G3 # keys: fault.io.pci.device-interr-deg # msgid "PCI-8000-G3.type" msgstr "Fault" msgid "PCI-8000-G3.severity" msgstr "Major" msgid "PCI-8000-G3.description" msgstr "An unrecoverable problem was detected for a PCI device, which has resulted in that device running in a degraded state.\n Refer to %s for more information." msgid "PCI-8000-G3.response" msgstr "None\n" msgid "PCI-8000-G3.impact" msgstr "Degraded services provided by the device instances associated with this fault\n" msgid "PCI-8000-G3.action" msgstr "Schedule a repair procedure to replace the affected device. Use fmadm faulty to identify the device or contact your illumos distribution team for support.\n" # # code: PCI-8000-HR # keys: fault.io.pci.fw_corrupt # msgid "PCI-8000-HR.type" msgstr "Fault" msgid "PCI-8000-HR.severity" msgstr "Major" msgid "PCI-8000-HR.description" msgstr "A firmware corruption was detected for a PCI device.\n Refer to %s for more information." msgid "PCI-8000-HR.response" msgstr "One or more device instances may be disabled.\n" msgid "PCI-8000-HR.impact" msgstr "Degraded services provided by the device instances associated with this fault.\n" msgid "PCI-8000-HR.action" msgstr "Use fmadm faulty to identify the device and then update the firmware to the latest version or schedule a repair procedure to replace the affected device. Contact your illumos distribution team for further information.\n" # # code: PCI-8000-J4 # keys: fault.io.pci.fw_mismatch # msgid "PCI-8000-J4.type" msgstr "Fault" msgid "PCI-8000-J4.severity" msgstr "Major" msgid "PCI-8000-J4.description" msgstr "A firmware version mismatch was detected for a PCI device.\n Refer to %s for more information." msgid "PCI-8000-J4.response" msgstr "One or more device instances may be disabled.\n" msgid "PCI-8000-J4.impact" msgstr "Degraded services provided by the device instances associated with this fault.\n" msgid "PCI-8000-J4.action" msgstr "Use fmadm faulty to identify the device and then update the firmware to the latest version. Contact your illumos distribution team for further information.\n"