xref: /illumos-gate/usr/src/man/man9f/physio.9f (revision bbf21555)
te
Copyright (c) 1997, Sun Microsystems, Inc.,
All Rights Reserved
The contents of this file are subject to the terms of the Common Development and Distribution License (the "License"). You may not use this file except in compliance with the License.
You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE or http://www.opensolaris.org/os/licensing. See the License for the specific language governing permissions and limitations under the License.
When distributing Covered Code, include this CDDL HEADER in each file and include the License file at usr/src/OPENSOLARIS.LICENSE. If applicable, add the following below this CDDL HEADER, with the fields enclosed by brackets "[]" replaced with your own identifying information: Portions Copyright [yyyy] [name of copyright owner]
PHYSIO 9F "Apr 2, 1993"
NAME
physio, minphys - perform physical I/O
SYNOPSIS
#include <sys/types.h>
#include <sys/buf.h>
#include <sys/uio.h>



int physio(int(*strat)(struct buf *), struct buf *bp, dev_t dev,
 int rw, void (*mincnt)(struct buf *), struct uio *uio);

void minphys(struct buf *bp);
INTERFACE LEVEL
illumos DDI specific (illumos DDI).
PARAMETERS
"physio()"
strat

Pointer to device strategy routine.

bp

Pointer to a buf(9S) structure describing the transfer. If bp is set to NULL then physio() allocates one which is automatically released upon completion.

dev

The device number.

rw

Read/write flag. This is either B_READ when reading from the device, or B_WRITE when writing to the device.

mincnt

Routine which bounds the maximum transfer unit size.

uio

Pointer to the uio structure which describes the user I/O request.

"minphys()"
bp

Pointer to a buf structure.

DESCRIPTION
physio() performs unbuffered I/O operations between the device dev and the address space described in the uio structure.

Prior to the start of the transfer physio() verifies the requested operation is valid by checking the protection of the address space specified in the uio structure. It then locks the pages involved in the I/O transfer so they can not be paged out. The device strategy routine, strat(), is then called one or more times to perform the physical I/O operations. physio() uses biowait(9F) to block until strat() has completed each transfer. Upon completion, or detection of an error, physio() unlocks the pages and returns the error status.

physio() uses mincnt() to bound the maximum transfer unit size to the system, or device, maximum length. minphys() is the system mincnt() routine for use with physio() operations. Drivers which do not provide their own local mincnt() routines should call physio() with minphys().

minphys() limits the value of bp->b_bcount to a sensible default for the capabilities of the system. Drivers that provide their own mincnt() routine should also call minphys() to make sure they do not exceed the system limit.

RETURN VALUES
physio() returns: 0

Upon success.

non-zero

Upon failure.

CONTEXT
physio() can be called from user context only.
SEE ALSO
strategy (9E), biodone (9F), biowait (9F), buf (9S), uio (9S)

Writing Device Drivers

WARNINGS
Since physio() calls biowait() to block until each buf transfer is complete, it is the drivers responsibility to call biodone(9F) when the transfer is complete, or physio() will block forever.