xref: /illumos-gate/usr/src/cmd/fm/dicts/SUNOS.po (revision bbf21555)
17c478bd9Sstevel@tonic-gate#
2f6e214c7SGavin Maltby# Copyright (c) 2010, Oracle and/or its affiliates. All rights reserved.
37c478bd9Sstevel@tonic-gate#
47c478bd9Sstevel@tonic-gate# CDDL HEADER START
57c478bd9Sstevel@tonic-gate#
67c478bd9Sstevel@tonic-gate# The contents of this file are subject to the terms of the
79dd0f810Scindi# Common Development and Distribution License (the "License").
89dd0f810Scindi# You may not use this file except in compliance with the License.
97c478bd9Sstevel@tonic-gate#
107c478bd9Sstevel@tonic-gate# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
117c478bd9Sstevel@tonic-gate# or http://www.opensolaris.org/os/licensing.
127c478bd9Sstevel@tonic-gate# See the License for the specific language governing permissions
137c478bd9Sstevel@tonic-gate# and limitations under the License.
147c478bd9Sstevel@tonic-gate#
157c478bd9Sstevel@tonic-gate# When distributing Covered Code, include this CDDL HEADER in each
167c478bd9Sstevel@tonic-gate# file and include the License file at usr/src/OPENSOLARIS.LICENSE.
177c478bd9Sstevel@tonic-gate# If applicable, add the following below this CDDL HEADER, with the
187c478bd9Sstevel@tonic-gate# fields enclosed by brackets "[]" replaced with your own identifying
197c478bd9Sstevel@tonic-gate# information: Portions Copyright [yyyy] [name of copyright owner]
207c478bd9Sstevel@tonic-gate#
217c478bd9Sstevel@tonic-gate# CDDL HEADER END
227c478bd9Sstevel@tonic-gate#
23f6e214c7SGavin Maltby
249dd0f810Scindi# DO NOT EDIT -- this file is generated by the Event Registry.
259dd0f810Scindi#
269dd0f810Scindi#
277c478bd9Sstevel@tonic-gate# code: SUNOS-8000-0G
287c478bd9Sstevel@tonic-gate# keys: ereport.sunos.unix.fm_panic
297c478bd9Sstevel@tonic-gate#
307c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-0G.type"
317c478bd9Sstevel@tonic-gatemsgstr "Error"
327c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-0G.severity"
337c478bd9Sstevel@tonic-gatemsgstr "Major"
347c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-0G.description"
357c478bd9Sstevel@tonic-gatemsgstr "Errors have been detected that require a reboot to ensure system integrity.  Refer to %s for more information."
367c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-0G.response"
37756113e7SDan McDonaldmsgstr "illumos will attempt to save and diagnose the error telemetry"
387c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-0G.impact"
397c478bd9Sstevel@tonic-gatemsgstr "The system will sync files, save a crash dump if needed, and reboot"
407c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-0G.action"
417c478bd9Sstevel@tonic-gatemsgstr "Save the error summary below in case telemetry cannot be saved"
427c478bd9Sstevel@tonic-gate#
437c478bd9Sstevel@tonic-gate# code: SUNOS-8000-1L
447c478bd9Sstevel@tonic-gate# keys: defect.sunos.eft.undiagnosable_problem
457c478bd9Sstevel@tonic-gate#
467c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-1L.type"
477c478bd9Sstevel@tonic-gatemsgstr "Defect"
487c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-1L.severity"
497c478bd9Sstevel@tonic-gatemsgstr "Minor"
507c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-1L.description"
519dd0f810Scindimsgstr "The EFT Diagnosis Engine encountered telemetry for which it is unable to produce a diagnosis.  Refer to %s for more information."
527c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-1L.response"
53756113e7SDan McDonaldmsgstr "Error reports from the component will be logged for examination by your illumos distribution team."
547c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-1L.impact"
557c478bd9Sstevel@tonic-gatemsgstr "Automated diagnosis and response for these events will not occur."
567c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-1L.action"
57756113e7SDan McDonaldmsgstr "Ensure that fault management software is installed properly. Contact your illumos distribution team for support."
587c478bd9Sstevel@tonic-gate#
597c478bd9Sstevel@tonic-gate# code: SUNOS-8000-20
609dd0f810Scindi# keys: defect.Deprecated defect.io.pci.driver fault.io.pci.bus fault.io.pci.device
617c478bd9Sstevel@tonic-gate#
627c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-20.type"
637c478bd9Sstevel@tonic-gatemsgstr "Fault"
647c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-20.severity"
657c478bd9Sstevel@tonic-gatemsgstr "Critical"
667c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-20.description"
679dd0f810Scindimsgstr "A problem was detected in the SUNOS subsystem or controlling software.  Refer to %s for more information."
687c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-20.response"
697c478bd9Sstevel@tonic-gatemsgstr "One or more of device instances may be disabled"
707c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-20.impact"
717c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
727c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-20.action"
73756113e7SDan McDonaldmsgstr "Ensure latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact your illumos distribution team for support."
747c478bd9Sstevel@tonic-gate#
757c478bd9Sstevel@tonic-gate# code: SUNOS-8000-3V
769dd0f810Scindi# keys: defect.Deprecated fault.io.pci.bus fault.io.pci.device
777c478bd9Sstevel@tonic-gate#
787c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-3V.type"
797c478bd9Sstevel@tonic-gatemsgstr "Fault"
807c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-3V.severity"
817c478bd9Sstevel@tonic-gatemsgstr "Critical"
827c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-3V.description"
839dd0f810Scindimsgstr "A problem was detected in the PCI subsystem.  Refer to %s for more information."
847c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-3V.response"
857c478bd9Sstevel@tonic-gatemsgstr "One or more of device instances may be disabled"
867c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-3V.impact"
877c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
887c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-3V.action"
89756113e7SDan McDonaldmsgstr "Schedule a repair procedure to replace the affected device. Use fmdump -v -u <EVENT_ID> to identify the device or contact your illumos distribution team for support."
907c478bd9Sstevel@tonic-gate#
917c478bd9Sstevel@tonic-gate# code: SUNOS-8000-46
929dd0f810Scindi# keys: defect.Deprecated defect.io.pci.driver fault.io.pci.device
937c478bd9Sstevel@tonic-gate#
947c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-46.type"
957c478bd9Sstevel@tonic-gatemsgstr "Fault"
967c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-46.severity"
977c478bd9Sstevel@tonic-gatemsgstr "Critical"
987c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-46.description"
999dd0f810Scindimsgstr "A problem was detected in the PCI subsystem or controlling software.  Refer to %s for more information."
1007c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-46.response"
1017c478bd9Sstevel@tonic-gatemsgstr "One or more of device instances may be disabled"
1027c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-46.impact"
1037c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
1047c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-46.action"
105756113e7SDan McDonaldmsgstr "Ensure latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact your illumos distribution team for support."
1067c478bd9Sstevel@tonic-gate#
1077c478bd9Sstevel@tonic-gate# code: SUNOS-8000-5T
1089dd0f810Scindi# keys: defect.Deprecated defect.io.pci.driver fault.io.pci.bus
1097c478bd9Sstevel@tonic-gate#
1107c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-5T.type"
1117c478bd9Sstevel@tonic-gatemsgstr "Fault"
1127c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-5T.severity"
1137c478bd9Sstevel@tonic-gatemsgstr "Critical"
1147c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-5T.description"
1159dd0f810Scindimsgstr "A problem was detected in the PCI subsystem or controlling software.  Refer to %s for more information."
1167c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-5T.response"
1177c478bd9Sstevel@tonic-gatemsgstr "One or more of device instances may be disabled"
1187c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-5T.impact"
1197c478bd9Sstevel@tonic-gatemsgstr "Loss of services provided by the device instances associated with this fault"
1207c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-5T.action"
121756113e7SDan McDonaldmsgstr "Ensure latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact your illumos distribution team for support."
1227c478bd9Sstevel@tonic-gate#
1237c478bd9Sstevel@tonic-gate# code: SUNOS-8000-69
1249dd0f810Scindi# keys: defect.Deprecated fault.io.pci.device
1257c478bd9Sstevel@tonic-gate#
1267c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-69.type"
1277c478bd9Sstevel@tonic-gatemsgstr "Fault"
1287c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-69.severity"
1297c478bd9Sstevel@tonic-gatemsgstr "Critical"
1307c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-69.description"
1319dd0f810Scindimsgstr "A problem was detected for a PCI controller  Refer to %s for more information."
1327c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-69.response"
1337c478bd9Sstevel@tonic-gatemsgstr "One or more of device instances may be disabled"
1347c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-69.impact"
1359dd0f810Scindimsgstr "Loss of services provided by the device instances associated with this fault."
1367c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-69.action"
137756113e7SDan McDonaldmsgstr "Schedule a repair procedure to replace the affected device. Use fmdump -v -u <EVENT_ID> to identify the device or contact your illumos distribution team for support."
1387c478bd9Sstevel@tonic-gate#
1397c478bd9Sstevel@tonic-gate# code: SUNOS-8000-7N
1409dd0f810Scindi# keys: defect.Deprecated fault.io.pci.bus
1417c478bd9Sstevel@tonic-gate#
1427c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-7N.type"
1437c478bd9Sstevel@tonic-gatemsgstr "Fault"
1447c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-7N.severity"
1457c478bd9Sstevel@tonic-gatemsgstr "Critical"
1467c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-7N.description"
1479dd0f810Scindimsgstr "A problem was detected for a PCI bus  Refer to %s for more information."
1487c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-7N.response"
1497c478bd9Sstevel@tonic-gatemsgstr "One or more of device instances may be disabled"
1507c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-7N.impact"
1519dd0f810Scindimsgstr "Loss of services provided by the device instances associated with this fault."
1527c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-7N.action"
153756113e7SDan McDonaldmsgstr "Schedule a repair procedure to replace the affected device. Use fmdump -v -u <EVENT_ID> to identify the device or contact your illumos distribution team for support."
1547c478bd9Sstevel@tonic-gate#
1557c478bd9Sstevel@tonic-gate# code: SUNOS-8000-8W
1569dd0f810Scindi# keys: defect.Deprecated defect.io.pci.driver
1577c478bd9Sstevel@tonic-gate#
1587c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-8W.type"
1597c478bd9Sstevel@tonic-gatemsgstr "Fault"
1607c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-8W.severity"
1617c478bd9Sstevel@tonic-gatemsgstr "Critical"
1627c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-8W.description"
1639dd0f810Scindimsgstr "A problem was detected in the PCI controller software  Refer to %s for more information."
1647c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-8W.response"
1657c478bd9Sstevel@tonic-gatemsgstr "One or more of device instances may be disabled"
1667c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-8W.impact"
1679dd0f810Scindimsgstr "Loss of services provided by the device instances associated with this fault."
1687c478bd9Sstevel@tonic-gatemsgid "SUNOS-8000-8W.action"
169756113e7SDan McDonaldmsgstr "Ensure latest drivers and patches are installed. Use fmdump -v -u <EVENT_ID> to identify the module/package, or contact your illumos distribution team for support."
1709dd0f810Scindi#
1719dd0f810Scindi# code: SUNOS-8000-91
1729dd0f810Scindi# keys: defect.sunos.zones.upgrade
1739dd0f810Scindi#
1749dd0f810Scindimsgid "SUNOS-8000-91.type"
1759dd0f810Scindimsgstr "Defect"
1769dd0f810Scindimsgid "SUNOS-8000-91.severity"
1779dd0f810Scindimsgstr "Minor"
1789dd0f810Scindimsgid "SUNOS-8000-91.description"
179756113e7SDan McDonaldmsgstr "\n	The illumos system or boot environment that is being upgraded\n	has non-global zones installed.  The current version of Live\n	Upgrade cannot upgrade a boot environment that has non-global\n	zones installed.\n	  Refer to %s for more information."
1809dd0f810Scindimsgid "SUNOS-8000-91.response"
1819dd0f810Scindimsgstr "The upgrade procedure has been terminated."
1829dd0f810Scindimsgid "SUNOS-8000-91.impact"
183756113e7SDan McDonaldmsgstr "The illumos system or boot environment is not upgraded."
1849dd0f810Scindimsgid "SUNOS-8000-91.action"
185756113e7SDan McDonaldmsgstr "\n	Evaluate each of the choices below and select the one that is\n	best for your needs.  Contact your illumos distribution team for support.\n	"
1869dd0f810Scindi#
1879dd0f810Scindi# code: SUNOS-8000-AK
1889dd0f810Scindi# keys: ereport.sunos.boot.upgrade.menu_lst
1899dd0f810Scindi#
1909dd0f810Scindimsgid "SUNOS-8000-AK.type"
1919dd0f810Scindimsgstr "Error"
1929dd0f810Scindimsgid "SUNOS-8000-AK.severity"
1939dd0f810Scindimsgstr "Critical"
1949dd0f810Scindimsgid "SUNOS-8000-AK.description"
195756113e7SDan McDonaldmsgstr "illumos could not automatically adjust\n/boot/grub/menu.lst\nto the new boot architecture\n  Refer to %s for more information."
1969dd0f810Scindimsgid "SUNOS-8000-AK.response"
197f6e214c7SGavin Maltbymsgstr "No automated response."
1989dd0f810Scindimsgid "SUNOS-8000-AK.impact"
199f6e214c7SGavin Maltbymsgstr "Future reboots could fail until this problem is corrected."
2009dd0f810Scindimsgid "SUNOS-8000-AK.action"
201f6e214c7SGavin Maltbymsgstr "Examine /boot/grub/menu.lst and revise as\ndescribed in Details."
2029dd0f810Scindi#
2039dd0f810Scindi# code: SUNOS-8000-CF
2049dd0f810Scindi# keys: ereport.sunos.boot.upgrade.menu_lst_bfu
2059dd0f810Scindi#
2069dd0f810Scindimsgid "SUNOS-8000-CF.type"
2079dd0f810Scindimsgstr "Error"
2089dd0f810Scindimsgid "SUNOS-8000-CF.severity"
2099dd0f810Scindimsgstr "Critical"
2109dd0f810Scindimsgid "SUNOS-8000-CF.description"
211756113e7SDan McDonaldmsgstr "illumos could not automatically adjust\n/boot/grub/menu.lst\nto the new boot architecture\n  Refer to %s for more information."
2129dd0f810Scindimsgid "SUNOS-8000-CF.response"
213f6e214c7SGavin Maltbymsgstr "No automated response."
2149dd0f810Scindimsgid "SUNOS-8000-CF.impact"
215f6e214c7SGavin Maltbymsgstr "Future reboots could fail until this problem is corrected."
2169dd0f810Scindimsgid "SUNOS-8000-CF.action"
217f6e214c7SGavin Maltbymsgstr "Examine /boot/grub/menu.lst and revise as\ndescribed in Details."
21832d4e834STarik Soydan#
21995efa359SEric Schrock# code: SUNOS-8000-DM
22095efa359SEric Schrock# keys: defect.sunos.smf.svc.maintenance
22195efa359SEric Schrock#
22295efa359SEric Schrockmsgid "SUNOS-8000-DM.type"
22395efa359SEric Schrockmsgstr "Defect"
22495efa359SEric Schrockmsgid "SUNOS-8000-DM.severity"
22595efa359SEric Schrockmsgstr "Major"
22695efa359SEric Schrockmsgid "SUNOS-8000-DM.description"
22795efa359SEric Schrockmsgstr "A service failed and could not be restarted.  Refer to %s for more information."
22895efa359SEric Schrockmsgid "SUNOS-8000-DM.response"
22995efa359SEric Schrockmsgstr "The service has been placed into the maintenance state."
23095efa359SEric Schrockmsgid "SUNOS-8000-DM.impact"
23195efa359SEric Schrockmsgstr "The service is unavailable."
23295efa359SEric Schrockmsgid "SUNOS-8000-DM.action"
233705e9f42SStephen Hansonmsgstr "Run 'svcs -x' to determine why the service failed and the location of logfiles, if any."
23495efa359SEric Schrock#
23532d4e834STarik Soydan# code: SUNOS-8000-E8
236bbc3b4a5STarik Soydan# keys: defect.sunos.eft.undiag.checkpoint
23732d4e834STarik Soydan#
23832d4e834STarik Soydanmsgid "SUNOS-8000-E8.type"
23932d4e834STarik Soydanmsgstr "Defect"
24032d4e834STarik Soydanmsgid "SUNOS-8000-E8.severity"
241bbc3b4a5STarik Soydanmsgstr "Minor"
24232d4e834STarik Soydanmsgid "SUNOS-8000-E8.description"
2439cdb3868STarik Soydanmsgstr "The diagnosis engine encountered an error while resuming diagnosis.  Refer to %s for more information."
24432d4e834STarik Soydanmsgid "SUNOS-8000-E8.response"
245756113e7SDan McDonaldmsgstr "Error reports have been logged for examination by your illumos distribution team."
24632d4e834STarik Soydanmsgid "SUNOS-8000-E8.impact"
2479cdb3868STarik Soydanmsgstr "Automated diagnosis and response for these events will not occur."
24832d4e834STarik Soydanmsgid "SUNOS-8000-E8.action"
2499cdb3868STarik Soydanmsgstr "Remove the diagnosis engine checkpoint file '/var/fm/fmd/ckpt/eft/eft', repair this defect, and restart the fault manager."
25032d4e834STarik Soydan#
25132d4e834STarik Soydan# code: SUNOS-8000-FU
252bbc3b4a5STarik Soydan# keys: defect.sunos.eft.undiag.fme
25332d4e834STarik Soydan#
25432d4e834STarik Soydanmsgid "SUNOS-8000-FU.type"
25532d4e834STarik Soydanmsgstr "Defect"
25632d4e834STarik Soydanmsgid "SUNOS-8000-FU.severity"
257bbc3b4a5STarik Soydanmsgstr "Major"
25832d4e834STarik Soydanmsgid "SUNOS-8000-FU.description"
2599cdb3868STarik Soydanmsgstr "The diagnosis engine encountered telemetry for which it was unable to perform a diagnosis.  Refer to %s for more information."
26032d4e834STarik Soydanmsgid "SUNOS-8000-FU.response"
261756113e7SDan McDonaldmsgstr "Error reports have been logged for examination by your illumos distribution team."
26232d4e834STarik Soydanmsgid "SUNOS-8000-FU.impact"
2639cdb3868STarik Soydanmsgstr "Automated diagnosis and response for these events will not occur."
26432d4e834STarik Soydanmsgid "SUNOS-8000-FU.action"
265756113e7SDan McDonaldmsgstr "Ensure that the latest illumos Kernel and Predictive Self-Healing (PSH) updates are installed."
26632d4e834STarik Soydan#
26732d4e834STarik Soydan# code: SUNOS-8000-G7
268bbc3b4a5STarik Soydan# keys: defect.sunos.eft.undiag.limit
26932d4e834STarik Soydan#
27032d4e834STarik Soydanmsgid "SUNOS-8000-G7.type"
27132d4e834STarik Soydanmsgstr "Defect"
27232d4e834STarik Soydanmsgid "SUNOS-8000-G7.severity"
27332d4e834STarik Soydanmsgstr "Minor"
27432d4e834STarik Soydanmsgid "SUNOS-8000-G7.description"
2759cdb3868STarik Soydanmsgstr "The diagnosis engine hit a limit restriction and was unable to perform a diagnosis.  Refer to %s for more information."
27632d4e834STarik Soydanmsgid "SUNOS-8000-G7.response"
277756113e7SDan McDonaldmsgstr "Error reports have been logged for examination by your illumos distribution team."
27832d4e834STarik Soydanmsgid "SUNOS-8000-G7.impact"
2799cdb3868STarik Soydanmsgstr "Automated diagnosis and response for these events will not occur."
28032d4e834STarik Soydanmsgid "SUNOS-8000-G7.action"
2819cdb3868STarik Soydanmsgstr "Check the diagnosis engine configuration file '/usr/lib/fm/fmd/plugins/eft.conf' and ensure that no limit restrictions are set, then repair this defect, and restart the fault manager."
282bbc3b4a5STarik Soydan#
283bbc3b4a5STarik Soydan# code: SUNOS-8000-HV
284bbc3b4a5STarik Soydan# keys: defect.sunos.eft.undiag.unknown
285bbc3b4a5STarik Soydan#
286bbc3b4a5STarik Soydanmsgid "SUNOS-8000-HV.type"
287bbc3b4a5STarik Soydanmsgstr "Defect"
288bbc3b4a5STarik Soydanmsgid "SUNOS-8000-HV.severity"
289bbc3b4a5STarik Soydanmsgstr "Minor"
290bbc3b4a5STarik Soydanmsgid "SUNOS-8000-HV.description"
2919cdb3868STarik Soydanmsgstr "The diagnosis engine encountered telemetry for which it was unable to perform a diagnosis.  Refer to %s for more information."
292bbc3b4a5STarik Soydanmsgid "SUNOS-8000-HV.response"
293756113e7SDan McDonaldmsgstr "Error reports have been logged for examination by your illumos distribution team."
294bbc3b4a5STarik Soydanmsgid "SUNOS-8000-HV.impact"
2959cdb3868STarik Soydanmsgstr "Automated diagnosis and response for these events will not occur."
296bbc3b4a5STarik Soydanmsgid "SUNOS-8000-HV.action"
297756113e7SDan McDonaldmsgstr "Ensure that the latest illumos Kernel and Predictive Self-Healing (PSH) updates are installed."
298705e9f42SStephen Hanson#
299705e9f42SStephen Hanson# code: SUNOS-8000-J0
300705e9f42SStephen Hanson# keys: defect.sunos.eft.unexpected_telemetry fault.sunos.eft.unexpected_telemetry
301705e9f42SStephen Hanson#
302705e9f42SStephen Hansonmsgid "SUNOS-8000-J0.type"
303705e9f42SStephen Hansonmsgstr "Fault"
304705e9f42SStephen Hansonmsgid "SUNOS-8000-J0.severity"
305705e9f42SStephen Hansonmsgstr "Major"
306705e9f42SStephen Hansonmsgid "SUNOS-8000-J0.description"
307f6e214c7SGavin Maltbymsgstr "The diagnosis engine encountered telemetry from the listed devices for which it was unable to perform a diagnosis - %.\n  Refer to %s for more information.  Refer to %s for more information."
308705e9f42SStephen Hansonmsgid "SUNOS-8000-J0.response"
309756113e7SDan McDonaldmsgstr "Error reports have been logged for examination by your illumos distribution team.\n"
310705e9f42SStephen Hansonmsgid "SUNOS-8000-J0.impact"
311705e9f42SStephen Hansonmsgstr "Automated diagnosis and response for these events will not occur.\n"
312705e9f42SStephen Hansonmsgid "SUNOS-8000-J0.action"
313756113e7SDan McDonaldmsgstr "Ensure that the latest illumos Kernel and Predictive Self-Healing (PSH) updates are installed.\n"
314f6e214c7SGavin Maltby#
315f6e214c7SGavin Maltby# code: SUNOS-8000-KL
316f6e214c7SGavin Maltby# keys: defect.sunos.kernel.panic
317f6e214c7SGavin Maltby#
318f6e214c7SGavin Maltbymsgid "SUNOS-8000-KL.type"
319f6e214c7SGavin Maltbymsgstr "Defect"
320f6e214c7SGavin Maltbymsgid "SUNOS-8000-KL.severity"
321f6e214c7SGavin Maltbymsgstr "Major"
322f6e214c7SGavin Maltbymsgid "SUNOS-8000-KL.description"
323f6e214c7SGavin Maltbymsgstr "The system has rebooted after a kernel panic.  Refer to %s for more information."
324f6e214c7SGavin Maltbymsgid "SUNOS-8000-KL.response"
325*bbf21555SRichard Lowemsgstr "The failed system image was dumped to the dump device.  If savecore is enabled (see dumpadm(8)) a copy of the dump will be written to the savecore directory %<fault-list[0].dump-dir>."
326f6e214c7SGavin Maltbymsgid "SUNOS-8000-KL.impact"
327f6e214c7SGavin Maltbymsgstr "There may be some performance impact while the panic is copied to the savecore directory.  Disk space usage by panics can be substantial."
328f6e214c7SGavin Maltbymsgid "SUNOS-8000-KL.action"
329f6e214c7SGavin Maltbymsgstr "If savecore is not enabled then please take steps to preserve the crash image.\nUse 'fmdump -Vp -u %<uuid>' to view more panic detail.  Please refer to the knowledge article for additional information."
330