xref: /illumos-gate/usr/src/cmd/fm/dicts/SCF.po (revision 756113e7)
1200c5a5aShueston#
2200c5a5aShueston# Copyright 2007 Sun Microsystems, Inc.  All rights reserved.
3200c5a5aShueston# Use is subject to license terms.
4200c5a5aShueston#
5200c5a5aShueston# CDDL HEADER START
6200c5a5aShueston#
7200c5a5aShueston# The contents of this file are subject to the terms of the
8200c5a5aShueston# Common Development and Distribution License (the "License").
9200c5a5aShueston# You may not use this file except in compliance with the License.
10200c5a5aShueston#
11200c5a5aShueston# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
12200c5a5aShueston# or http://www.opensolaris.org/os/licensing.
13200c5a5aShueston# See the License for the specific language governing permissions
14200c5a5aShueston# and limitations under the License.
15200c5a5aShueston#
16200c5a5aShueston# When distributing Covered Code, include this CDDL HEADER in each
17200c5a5aShueston# file and include the License file at usr/src/OPENSOLARIS.LICENSE.
18200c5a5aShueston# If applicable, add the following below this CDDL HEADER, with the
19200c5a5aShueston# fields enclosed by brackets "[]" replaced with your own identifying
20200c5a5aShueston# information: Portions Copyright [yyyy] [name of copyright owner]
21200c5a5aShueston#
22200c5a5aShueston# CDDL HEADER END
23200c5a5aShueston#
24200c5a5aShueston# DO NOT EDIT -- this file is generated by the Event Registry.
25200c5a5aShueston#
26200c5a5aShueston#
27200c5a5aShueston# code: SCF-8000-1D
28200c5a5aShueston# keys: fault.chassis.SPARC-Enterprise.if.fe-asic-clk
29200c5a5aShueston#
30200c5a5aShuestonmsgid "SCF-8000-1D.type"
31200c5a5aShuestonmsgstr "Fault"
32200c5a5aShuestonmsgid "SCF-8000-1D.severity"
33200c5a5aShuestonmsgstr "Critical"
34200c5a5aShuestonmsgid "SCF-8000-1D.description"
35200c5a5aShuestonmsgstr "A fatal clock distribution error was detected by an ASIC or a CPU chip.\n  Refer to %s for more information."
36200c5a5aShuestonmsgid "SCF-8000-1D.response"
37200c5a5aShuestonmsgstr "An attempt will be made to deconfigure the faulty components after one or more domains are reset.\n"
38200c5a5aShuestonmsgid "SCF-8000-1D.impact"
39200c5a5aShuestonmsgstr "One or more domains will be reset. Please consult the detail section of the knowledge article for \nadditional information.\n"
40200c5a5aShuestonmsgid "SCF-8000-1D.action"
41200c5a5aShuestonmsgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
42200c5a5aShueston#
43200c5a5aShueston# code: SCF-8000-2Y
44200c5a5aShueston# keys: fault.chassis.SPARC-Enterprise.if.fe-clk-cable
45200c5a5aShueston#
46200c5a5aShuestonmsgid "SCF-8000-2Y.type"
47200c5a5aShuestonmsgstr "Fault"
48200c5a5aShuestonmsgid "SCF-8000-2Y.severity"
49200c5a5aShuestonmsgstr "Critical"
50200c5a5aShuestonmsgid "SCF-8000-2Y.description"
51200c5a5aShuestonmsgstr "A Clock chip has detected a lack of connectivity between the base cabinet and the expansion cabinet.\n  Refer to %s for more information."
52200c5a5aShuestonmsgid "SCF-8000-2Y.response"
53200c5a5aShuestonmsgstr "The entire platform is reset and the active Clock Units are deconfigured during recovery.\n"
54200c5a5aShuestonmsgid "SCF-8000-2Y.impact"
55200c5a5aShuestonmsgstr "The entire platform is reset and the active Clock Units are deconfigured during recovery.\n"
56200c5a5aShuestonmsgid "SCF-8000-2Y.action"
57200c5a5aShuestonmsgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
58200c5a5aShueston#
59200c5a5aShueston# code: SCF-8000-33
60200c5a5aShueston# keys: fault.chassis.SPARC-Enterprise.asic.clk.fe
61200c5a5aShueston#
62200c5a5aShuestonmsgid "SCF-8000-33.type"
63200c5a5aShuestonmsgstr "Fault"
64200c5a5aShuestonmsgid "SCF-8000-33.severity"
65200c5a5aShuestonmsgstr "Critical"
66200c5a5aShuestonmsgid "SCF-8000-33.description"
67200c5a5aShuestonmsgstr "A fatal error was detected within a Clock chip.\n  Refer to %s for more information."
68200c5a5aShuestonmsgid "SCF-8000-33.response"
69200c5a5aShuestonmsgstr "The platform will be reset. If there is redundant clock capability, an attempt will be made to deconfigure \nthe active Clock Unit from service. \n"
70200c5a5aShuestonmsgid "SCF-8000-33.impact"
71200c5a5aShuestonmsgstr "If the platform lacks redundant clock capability, the platform will be powered down and will not\npower up. If the platform has redundant clock capability, the platform will be reset and the\nfaulty Clock Unit will be deconfigured during recovery.\n"
72200c5a5aShuestonmsgid "SCF-8000-33.action"
73200c5a5aShuestonmsgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
74200c5a5aShueston#
75200c5a5aShueston# code: SCF-8000-4S
76200c5a5aShueston# keys: fault.chassis.SPARC-Enterprise.asic.clk.test
77200c5a5aShueston#
78200c5a5aShuestonmsgid "SCF-8000-4S.type"
79200c5a5aShuestonmsgstr "Fault"
80200c5a5aShuestonmsgid "SCF-8000-4S.severity"
81200c5a5aShuestonmsgstr "Critical"
82200c5a5aShuestonmsgid "SCF-8000-4S.description"
83200c5a5aShuestonmsgstr "Fault was detected during poweron self-test, either within a Clock chip with within one of the external\ninterfaces of a Clock chip.\n  Refer to %s for more information."
84200c5a5aShuestonmsgid "SCF-8000-4S.response"
85200c5a5aShuestonmsgstr "An attempt will be made to remove the affected components from service. Please consult the detail \nsection of the knowledge article for additional information.\n"
86200c5a5aShuestonmsgid "SCF-8000-4S.impact"
87200c5a5aShuestonmsgstr "The entire platform is reset. If the platform lacks redundant clock capability, the platform will be \npowered down and will not power up. If the platform has redundant clock capability, the platform will be \nreset and the faulty Clock Unit will be deconfigured during recovery.\n"
88200c5a5aShuestonmsgid "SCF-8000-4S.action"
89200c5a5aShuestonmsgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
90200c5a5aShueston#
91200c5a5aShueston# code: SCF-8000-CJ
92200c5a5aShueston# keys: fault.chassis.SPARC-Enterprise.cpu.SPARC64-VI.fe
93200c5a5aShueston#
94200c5a5aShuestonmsgid "SCF-8000-CJ.type"
95200c5a5aShuestonmsgstr "Fault"
96200c5a5aShuestonmsgid "SCF-8000-CJ.severity"
97200c5a5aShuestonmsgstr "Critical"
98200c5a5aShuestonmsgid "SCF-8000-CJ.description"
99200c5a5aShuestonmsgstr "An internal fatal error within a CPU chip was detected.\n  Refer to %s for more information."
100200c5a5aShuestonmsgid "SCF-8000-CJ.response"
101200c5a5aShuestonmsgstr "The domain using this CPU will be reset and the CPU chip will be deconfigured.\n"
102200c5a5aShuestonmsgid "SCF-8000-CJ.impact"
103200c5a5aShuestonmsgstr "The CPU chip will be deconfigured after the domain is reset.\n"
104200c5a5aShuestonmsgid "SCF-8000-CJ.action"
105200c5a5aShuestonmsgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
106200c5a5aShueston#
107200c5a5aShueston# code: SCF-8000-DC
108200c5a5aShueston# keys: fault.chassis.SPARC-Enterprise.cpu.SPARC64-VI.core.fe
109200c5a5aShueston#
110200c5a5aShuestonmsgid "SCF-8000-DC.type"
111200c5a5aShuestonmsgstr "Fault"
112200c5a5aShuestonmsgid "SCF-8000-DC.severity"
113200c5a5aShuestonmsgstr "Critical"
114200c5a5aShuestonmsgid "SCF-8000-DC.description"
115200c5a5aShuestonmsgstr "An internal fatal error within a core on a CPU chip was detected.\n  Refer to %s for more information."
116200c5a5aShuestonmsgid "SCF-8000-DC.response"
117200c5a5aShuestonmsgstr "The domain using this CPU will be reset and the core will be deconfigured.\n"
118200c5a5aShuestonmsgid "SCF-8000-DC.impact"
119200c5a5aShuestonmsgstr "The domain using this CPU chip is reset.\n"
120200c5a5aShuestonmsgid "SCF-8000-DC.action"
121200c5a5aShuestonmsgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
122200c5a5aShueston#
123200c5a5aShueston# code: SCF-8000-EQ
124200c5a5aShueston# keys: fault.chassis.SPARC-Enterprise.cpu.SPARC64-VI.core.strand.fe
125200c5a5aShueston#
126200c5a5aShuestonmsgid "SCF-8000-EQ.type"
127200c5a5aShuestonmsgstr "Fault"
128200c5a5aShuestonmsgid "SCF-8000-EQ.severity"
129200c5a5aShuestonmsgstr "Critical"
130200c5a5aShuestonmsgid "SCF-8000-EQ.description"
131200c5a5aShuestonmsgstr "An internal fatal error within a strand on a CPU chip was detected.\n  Refer to %s for more information."
132200c5a5aShuestonmsgid "SCF-8000-EQ.response"
133200c5a5aShuestonmsgstr "The domain using this CPU will be reset and the strand will be deconfigured.\n"
134200c5a5aShuestonmsgid "SCF-8000-EQ.impact"
135200c5a5aShuestonmsgstr "The domain using this CPU chip is reset.\n"
136200c5a5aShuestonmsgid "SCF-8000-EQ.action"
137200c5a5aShuestonmsgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
138200c5a5aShueston#
139200c5a5aShueston# code: SCF-8000-F4
140200c5a5aShueston# keys: fault.chassis.SPARC-Enterprise.cpu.SPARC64-VI.se
141200c5a5aShueston#
142200c5a5aShuestonmsgid "SCF-8000-F4.type"
143200c5a5aShuestonmsgstr "Fault"
144200c5a5aShuestonmsgid "SCF-8000-F4.severity"
145200c5a5aShuestonmsgstr "Major"
146200c5a5aShuestonmsgid "SCF-8000-F4.description"
147200c5a5aShuestonmsgstr "An internal non-fatal uncorrectable error within a CPU chip has been detected.\n  Refer to %s for more information."
148200c5a5aShuestonmsgid "SCF-8000-F4.response"
149200c5a5aShuestonmsgstr "The CPU chip will be deconfigured after the platform is power cycled or after the domain reboots \nor after a Dynamic Reconfiguration operation is performed.\n"
150200c5a5aShuestonmsgid "SCF-8000-F4.impact"
151200c5a5aShuestonmsgstr "The non-fatal uncorrectable error may cause domain to panic. The CPU chip will be deconfigured after the \nplatform is power cycled or after the domain reboots or after a Dynamic Reconfiguration operation is performed.\n"
152200c5a5aShuestonmsgid "SCF-8000-F4.action"
153200c5a5aShuestonmsgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
154200c5a5aShueston#
155200c5a5aShueston# code: SCF-8000-GR
156200c5a5aShueston# keys: fault.chassis.SPARC-Enterprise.cpu.SPARC64-VI.core.se
157200c5a5aShueston#
158200c5a5aShuestonmsgid "SCF-8000-GR.type"
159200c5a5aShuestonmsgstr "Fault"
160200c5a5aShuestonmsgid "SCF-8000-GR.severity"
161200c5a5aShuestonmsgstr "Major"
162200c5a5aShuestonmsgid "SCF-8000-GR.description"
163200c5a5aShuestonmsgstr "A non-fatal uncorrectable error associated with a core on a CPU chip has been detected.\n  Refer to %s for more information."
164200c5a5aShuestonmsgid "SCF-8000-GR.response"
165200c5a5aShuestonmsgstr "The domain software will attempt to offline the core on the CPU chip.\n"
166200c5a5aShuestonmsgid "SCF-8000-GR.impact"
167200c5a5aShuestonmsgstr "The non-fatal uncorrectable error trap may cause the domain to panic. If the domain\ndoes not panic, the domain software will attempt to offline the core on the CPU chip.\nThe core of the CPU chip will be deconfigured after the platform is power cycled or \nafter the domain reboots or after a Dynamic Reconfiguration operation is performed.\n"
168200c5a5aShuestonmsgid "SCF-8000-GR.action"
169200c5a5aShuestonmsgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
170200c5a5aShueston#
171200c5a5aShueston# code: SCF-8000-H3
172200c5a5aShueston# keys: fault.chassis.SPARC-Enterprise.cpu.SPARC64-VI.core.se-offlinereq
173200c5a5aShueston#
174200c5a5aShuestonmsgid "SCF-8000-H3.type"
175200c5a5aShuestonmsgstr "Fault"
176200c5a5aShuestonmsgid "SCF-8000-H3.severity"
177200c5a5aShuestonmsgstr "Major"
178200c5a5aShuestonmsgid "SCF-8000-H3.description"
179200c5a5aShuestonmsgstr "When a non-fatal uncorrectable error occurs on a core on a CPU chip, domain software attempts to\noffline the core. This fault occurs when the number of offline attempts has exceeded an\nacceptable threshold.\n  Refer to %s for more information."
180200c5a5aShuestonmsgid "SCF-8000-H3.response"
181200c5a5aShuestonmsgstr "Future non-fatal uncorrectable errors for this core on a CPU chip will not be recorded on the XSCF.\n"
182200c5a5aShuestonmsgid "SCF-8000-H3.impact"
183200c5a5aShuestonmsgstr "The uncorrectable error trap may cause the domain to panic.\n"
184200c5a5aShuestonmsgid "SCF-8000-H3.action"
185200c5a5aShuestonmsgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
186200c5a5aShueston#
187200c5a5aShueston# code: SCF-8000-JY
188200c5a5aShueston# keys: fault.chassis.SPARC-Enterprise.cpu.SPARC64-VI.core.strand.se
189200c5a5aShueston#
190200c5a5aShuestonmsgid "SCF-8000-JY.type"
191200c5a5aShuestonmsgstr "Fault"
192200c5a5aShuestonmsgid "SCF-8000-JY.severity"
193200c5a5aShuestonmsgstr "Major"
194200c5a5aShuestonmsgid "SCF-8000-JY.description"
195200c5a5aShuestonmsgstr "A non-fatal uncorrectable error has been detected on a strand on a CPU chip.\n  Refer to %s for more information."
196200c5a5aShuestonmsgid "SCF-8000-JY.response"
197200c5a5aShuestonmsgstr "The strand on the CPU chip is deconfigured.\n"
198200c5a5aShuestonmsgid "SCF-8000-JY.impact"
199200c5a5aShuestonmsgstr "The non-fatal uncorrectable error trap may cause the domain to panic.\n"
200200c5a5aShuestonmsgid "SCF-8000-JY.action"
201200c5a5aShuestonmsgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
202200c5a5aShueston#
203200c5a5aShueston# code: SCF-8000-KD
204200c5a5aShueston# keys: fault.chassis.SPARC-Enterprise.cpu.SPARC64-VI.ce
205200c5a5aShueston#
206200c5a5aShuestonmsgid "SCF-8000-KD.type"
207200c5a5aShuestonmsgstr "Fault"
208200c5a5aShuestonmsgid "SCF-8000-KD.severity"
209200c5a5aShuestonmsgstr "Major"
210200c5a5aShuestonmsgid "SCF-8000-KD.description"
211200c5a5aShuestonmsgstr "The number of correctable errors associated with a CPU chip has exceeded an acceptable threshold.\n  Refer to %s for more information."
212200c5a5aShuestonmsgid "SCF-8000-KD.response"
213200c5a5aShuestonmsgstr "The CPU chip will be deconfigured after the platform is power cycled or \nafter the domain reboots or after a Dynamic Reconfiguration operation is performed.\n"
214200c5a5aShuestonmsgid "SCF-8000-KD.impact"
215200c5a5aShuestonmsgstr "No immediate impact. The CPU chip will be deconfigured after the platform is power cycled or \nafter the domain reboots or after a Dynamic Reconfiguration operation is performed.\n"
216200c5a5aShuestonmsgid "SCF-8000-KD.action"
217200c5a5aShuestonmsgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
218200c5a5aShueston#
219200c5a5aShueston# code: SCF-8000-LH
220200c5a5aShueston# keys: fault.chassis.SPARC-Enterprise.cpu.SPARC64-VI.core.ce
221200c5a5aShueston#
222200c5a5aShuestonmsgid "SCF-8000-LH.type"
223200c5a5aShuestonmsgstr "Fault"
224200c5a5aShuestonmsgid "SCF-8000-LH.severity"
225200c5a5aShuestonmsgstr "Major"
226200c5a5aShuestonmsgid "SCF-8000-LH.description"
227200c5a5aShuestonmsgstr "The number of correctable errors associated with a core on a CPU chip have exceeded an acceptable threshold.\n  Refer to %s for more information."
228200c5a5aShuestonmsgid "SCF-8000-LH.response"
229200c5a5aShuestonmsgstr "A request is sent to the domain software to attempt to offline the core on the CPU chip.\nThe core of the CPU chip will be deconfigured after the platform is power cycled or \nafter the domain reboots or after a Dynamic Reconfiguration operation is performed.\n"
230200c5a5aShuestonmsgid "SCF-8000-LH.impact"
231200c5a5aShuestonmsgstr "No immediate impact.\n"
232200c5a5aShuestonmsgid "SCF-8000-LH.action"
233200c5a5aShuestonmsgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
234200c5a5aShueston#
235200c5a5aShueston# code: SCF-8000-MA
236200c5a5aShueston# keys: fault.chassis.SPARC-Enterprise.cpu.SPARC64-VI.core.ce-offlinereq
237200c5a5aShueston#
238200c5a5aShuestonmsgid "SCF-8000-MA.type"
239200c5a5aShuestonmsgstr "Fault"
240200c5a5aShuestonmsgid "SCF-8000-MA.severity"
241200c5a5aShuestonmsgstr "Major"
242200c5a5aShuestonmsgid "SCF-8000-MA.description"
243200c5a5aShuestonmsgstr "The number of correctable errors on a core on a CPU chip has exceeded an acceptable threshold. \nThis fault occurs when the number of offline attempts has exceeded an acceptable threshold.\n  Refer to %s for more information."
244200c5a5aShuestonmsgid "SCF-8000-MA.response"
245200c5a5aShuestonmsgstr "Future correctable errors for this core on a CPU chip will not be recorded on the XSCF.\n"
246200c5a5aShuestonmsgid "SCF-8000-MA.impact"
247200c5a5aShuestonmsgstr "No immediate impact.\n"
248200c5a5aShuestonmsgid "SCF-8000-MA.action"
249200c5a5aShuestonmsgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
250200c5a5aShueston#
251200c5a5aShueston# code: SCF-8000-NP
252200c5a5aShueston# keys: fault.chassis.SPARC-Enterprise.cpu.SPARC64-VI.way.ce
253200c5a5aShueston#
254200c5a5aShuestonmsgid "SCF-8000-NP.type"
255200c5a5aShuestonmsgstr "Fault"
256200c5a5aShuestonmsgid "SCF-8000-NP.severity"
257200c5a5aShuestonmsgstr "Minor"
258200c5a5aShuestonmsgid "SCF-8000-NP.description"
259200c5a5aShuestonmsgstr "The number of correctable errors within a way of a CPU chip's L2 cache has exceeded an acceptable threshold.\n  Refer to %s for more information."
260200c5a5aShuestonmsgid "SCF-8000-NP.response"
261200c5a5aShuestonmsgstr "The way of the CPU chip's cache is deconfigured. The performance of the CPU chip is reduced.\n"
262200c5a5aShuestonmsgid "SCF-8000-NP.impact"
263200c5a5aShuestonmsgstr "There is a performance loss for the CPU chip.\n"
264200c5a5aShuestonmsgid "SCF-8000-NP.action"
265200c5a5aShuestonmsgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
266200c5a5aShueston#
267200c5a5aShueston# code: SCF-8000-P5
268200c5a5aShueston# keys: upset.chassis.SPARC-Enterprise.cpu.SPARC64-VI.fe
269200c5a5aShueston#
270200c5a5aShuestonmsgid "SCF-8000-P5.type"
271200c5a5aShuestonmsgstr "Upset"
272200c5a5aShuestonmsgid "SCF-8000-P5.severity"
273200c5a5aShuestonmsgstr "Critical"
274200c5a5aShuestonmsgid "SCF-8000-P5.description"
275200c5a5aShuestonmsgstr "A hard-to-diagnose problem was detected by the CPU chip.\n  Refer to %s for more information."
276200c5a5aShuestonmsgid "SCF-8000-P5.response"
277200c5a5aShuestonmsgstr "Nothing is deconfigured.\n"
278200c5a5aShuestonmsgid "SCF-8000-P5.impact"
279200c5a5aShuestonmsgstr "The domain may drop to the OpenBoot PROM 'OK' prompt.\n"
280200c5a5aShuestonmsgid "SCF-8000-P5.action"
281200c5a5aShuestonmsgstr "The platform administrator should check to see if any other hardware failure has occurred on the platform.\nIf the problem occurs while running OpenBoot PROM, then the platform administrator should check to make sure that \nthe OpenBoot PROM environment variables have not been set incorrectly. If neither of these courses of action \nprovide a resolution, then the platform administrator should schedule a service action.\nPlease consult the detail section of the knowledge article for additional information.\n"
282200c5a5aShueston#
283200c5a5aShueston# code: SCF-8000-QS
284200c5a5aShueston# keys: upset.chassis.SPARC-Enterprise.cpu.SPARC64-VI.fe-unexpected-trap
285200c5a5aShueston#
286200c5a5aShuestonmsgid "SCF-8000-QS.type"
287200c5a5aShuestonmsgstr "upset"
288200c5a5aShuestonmsgid "SCF-8000-QS.severity"
289200c5a5aShuestonmsgstr "Critical"
290200c5a5aShuestonmsgid "SCF-8000-QS.description"
291200c5a5aShuestonmsgstr "An unexpected trap with some unknown cause was detected by a CPU chip during POST.\n  Refer to %s for more information."
292200c5a5aShuestonmsgid "SCF-8000-QS.response"
293200c5a5aShuestonmsgstr "Nothing is deconfigured.\n"
294200c5a5aShuestonmsgid "SCF-8000-QS.impact"
295200c5a5aShuestonmsgstr "The domain is reset.\n"
296200c5a5aShuestonmsgid "SCF-8000-QS.action"
297200c5a5aShuestonmsgstr "Please consult the detail section of the knowledge article for additional information.\n"
298200c5a5aShueston#
299200c5a5aShueston# code: SCF-8000-RJ
300200c5a5aShueston# keys: fault.chassis.SPARC-Enterprise.cpu.SPARC64-VI.se-tmo
301200c5a5aShueston#
302200c5a5aShuestonmsgid "SCF-8000-RJ.type"
303200c5a5aShuestonmsgstr "Fault"
304200c5a5aShuestonmsgid "SCF-8000-RJ.severity"
305200c5a5aShuestonmsgstr "Major"
306200c5a5aShuestonmsgid "SCF-8000-RJ.description"
307200c5a5aShuestonmsgstr "An internal non-fatal uncorrectable error has been detected within the CPU chip.\n  Refer to %s for more information."
308200c5a5aShuestonmsgid "SCF-8000-RJ.response"
309200c5a5aShuestonmsgstr "Nothing is deconfigured.\n"
310200c5a5aShuestonmsgid "SCF-8000-RJ.impact"
311200c5a5aShuestonmsgstr "The non-fatal uncorrectable error may cause the domain to panic.\n"
312200c5a5aShuestonmsgid "SCF-8000-RJ.action"
313200c5a5aShuestonmsgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
314200c5a5aShueston#
315200c5a5aShueston# code: SCF-8000-SE
316200c5a5aShueston# keys: fault.chassis.SPARC-Enterprise.cpu.SPARC64-VI.se-uncertain
317200c5a5aShueston#
318200c5a5aShuestonmsgid "SCF-8000-SE.type"
319200c5a5aShuestonmsgstr "Fault"
320200c5a5aShuestonmsgid "SCF-8000-SE.severity"
321200c5a5aShuestonmsgstr "Major"
322200c5a5aShuestonmsgid "SCF-8000-SE.description"
323200c5a5aShuestonmsgstr "An internal non-fatal uncorrectable error has been detected within the CPU chip.\n  Refer to %s for more information."
324200c5a5aShuestonmsgid "SCF-8000-SE.response"
325200c5a5aShuestonmsgstr "Nothing is deconfigured.\n"
326200c5a5aShuestonmsgid "SCF-8000-SE.impact"
327200c5a5aShuestonmsgstr "The non-fatal uncorrectable error may cause the domain to panic.\n"
328200c5a5aShuestonmsgid "SCF-8000-SE.action"
329200c5a5aShuestonmsgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
330200c5a5aShueston#
331200c5a5aShueston# code: SCF-8000-TX
332200c5a5aShueston# keys: fault.chassis.SPARC-Enterprise.cpu.SPARC64-VI.core.ce-warn
333200c5a5aShueston#
334200c5a5aShuestonmsgid "SCF-8000-TX.type"
335200c5a5aShuestonmsgstr "Fault"
336200c5a5aShuestonmsgid "SCF-8000-TX.severity"
337200c5a5aShuestonmsgstr "Minor"
338200c5a5aShuestonmsgid "SCF-8000-TX.description"
339200c5a5aShuestonmsgstr "The number of correctable errors associated with a CPU chip has exceeded an acceptable threshold.\n  Refer to %s for more information."
340200c5a5aShuestonmsgid "SCF-8000-TX.response"
341200c5a5aShuestonmsgstr "Nothing is deconfigured.\n"
342200c5a5aShuestonmsgid "SCF-8000-TX.impact"
343200c5a5aShuestonmsgstr "No immediate impact.\n"
344200c5a5aShuestonmsgid "SCF-8000-TX.action"
345200c5a5aShuestonmsgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
346200c5a5aShueston#
347200c5a5aShueston# code: SCF-8000-YC
348200c5a5aShueston# keys: fault.chassis.SPARC-Enterprise.memory.fe
349200c5a5aShueston#
350200c5a5aShuestonmsgid "SCF-8000-YC.type"
351200c5a5aShuestonmsgstr "Fault"
352200c5a5aShuestonmsgid "SCF-8000-YC.severity"
353200c5a5aShuestonmsgstr "Major"
354200c5a5aShuestonmsgid "SCF-8000-YC.description"
355200c5a5aShuestonmsgstr "A fatal error in a DIMM was detected by POST.\n  Refer to %s for more information."
356200c5a5aShuestonmsgid "SCF-8000-YC.response"
357200c5a5aShuestonmsgstr "The memory associated with the memory bank that contains this\nDIMM is deconfigured.\n"
358200c5a5aShuestonmsgid "SCF-8000-YC.impact"
359200c5a5aShuestonmsgstr "POST is restarted after the memory associated with the memory bank that contains\nthis DIMM has been deconfigured.\n"
360200c5a5aShuestonmsgid "SCF-8000-YC.action"
361200c5a5aShuestonmsgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
362200c5a5aShueston#
363200c5a5aShueston# code: SCF-8001-0Q
364200c5a5aShueston# keys: fault.chassis.SPARC-Enterprise.memory.block.ue
365200c5a5aShueston#
366200c5a5aShuestonmsgid "SCF-8001-0Q.type"
367200c5a5aShuestonmsgstr "Fault"
368200c5a5aShuestonmsgid "SCF-8001-0Q.severity"
369200c5a5aShuestonmsgstr "Major"
370200c5a5aShuestonmsgid "SCF-8001-0Q.description"
371200c5a5aShuestonmsgstr "An uncorrectable memory error (UE) has been detected.\n  Refer to %s for more information."
372200c5a5aShuestonmsgid "SCF-8001-0Q.response"
373200c5a5aShuestonmsgstr "The 64MB of memory containing the memory that caused the UE will be deconfigured after the \nplatform is power cycled or after the domain reboots or after a Dynamic Reconfiguration operation \nis performed.\n"
374200c5a5aShuestonmsgid "SCF-8001-0Q.impact"
375200c5a5aShuestonmsgstr "The domain will receive an uncorrectable error trap which may cause the domain to panic. \n"
376200c5a5aShuestonmsgid "SCF-8001-0Q.action"
377200c5a5aShuestonmsgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
378200c5a5aShueston#
379200c5a5aShueston# code: SCF-8001-1C
380200c5a5aShueston# keys: fault.chassis.SPARC-Enterprise.memory.block.mirror.ue
381200c5a5aShueston#
382200c5a5aShuestonmsgid "SCF-8001-1C.type"
383200c5a5aShuestonmsgstr "Fault"
384200c5a5aShuestonmsgid "SCF-8001-1C.severity"
385200c5a5aShuestonmsgstr "Major"
386200c5a5aShuestonmsgid "SCF-8001-1C.description"
387200c5a5aShuestonmsgstr "A data compare error has been detected within a MAC chip when memory is in mirror mode.\n  Refer to %s for more information."
388200c5a5aShuestonmsgid "SCF-8001-1C.response"
389200c5a5aShuestonmsgstr "The memory associated with the MAC chip will be deconfigured after the platform is power cycled \nor after the domain reboots or after a Dynamic Reconfiguration operation is performed.\n"
390200c5a5aShuestonmsgid "SCF-8001-1C.impact"
391200c5a5aShuestonmsgstr "The domain will receive an uncorrectable error trap which may cause the domain to panic. \n"
392200c5a5aShuestonmsgid "SCF-8001-1C.action"
393200c5a5aShuestonmsgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
394200c5a5aShueston#
395200c5a5aShueston# code: SCF-8001-2R
396200c5a5aShueston# keys: fault.chassis.SPARC-Enterprise.memory.block.pce
397200c5a5aShueston#
398200c5a5aShuestonmsgid "SCF-8001-2R.type"
399200c5a5aShuestonmsgstr "Fault"
400200c5a5aShuestonmsgid "SCF-8001-2R.severity"
401200c5a5aShuestonmsgstr "Minor"
402200c5a5aShuestonmsgid "SCF-8001-2R.description"
403200c5a5aShuestonmsgstr "A permanent correctable memory error (PCE) has been detected.\n  Refer to %s for more information."
404200c5a5aShuestonmsgid "SCF-8001-2R.response"
405200c5a5aShuestonmsgstr "The 64MB chunk of memory that contains the permanent correctable error will be deconfigured after the \nplatform is power cycled or after the domain reboots or after a Dynamic Reconfiguration operation is performed.\n"
406200c5a5aShuestonmsgid "SCF-8001-2R.impact"
407200c5a5aShuestonmsgstr "Minimal impact.\n"
408200c5a5aShuestonmsgid "SCF-8001-2R.action"
409200c5a5aShuestonmsgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
410200c5a5aShueston#
411200c5a5aShueston# code: SCF-8001-34
412200c5a5aShueston# keys: fault.chassis.SPARC-Enterprise.memory.dimm.pce
413200c5a5aShueston#
414200c5a5aShuestonmsgid "SCF-8001-34.type"
415200c5a5aShuestonmsgstr "Fault"
416200c5a5aShuestonmsgid "SCF-8001-34.severity"
417200c5a5aShuestonmsgstr "Minor"
418200c5a5aShuestonmsgid "SCF-8001-34.description"
419200c5a5aShuestonmsgstr "The number of permanent correctable errors (PCE's) on single DIMM exceeds an\nacceptable threshold.\n  Refer to %s for more information."
420200c5a5aShuestonmsgid "SCF-8001-34.response"
421200c5a5aShuestonmsgstr "No immediate action is taken and nothing is deconfigured.\n"
422200c5a5aShuestonmsgid "SCF-8001-34.impact"
423200c5a5aShuestonmsgstr "Minimal impact to system.\n"
424200c5a5aShuestonmsgid "SCF-8001-34.action"
425200c5a5aShuestonmsgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
426200c5a5aShueston#
427200c5a5aShueston# code: SCF-8001-4X
428200c5a5aShueston# keys: fault.chassis.SPARC-Enterprise.memory.bank.err
429200c5a5aShueston#
430200c5a5aShuestonmsgid "SCF-8001-4X.type"
431200c5a5aShuestonmsgstr "Fault"
432200c5a5aShuestonmsgid "SCF-8001-4X.severity"
433200c5a5aShuestonmsgstr "Major"
434200c5a5aShuestonmsgid "SCF-8001-4X.description"
435200c5a5aShuestonmsgstr "The number of uncorrectable and correctable errors on single DIMM exceeds an\nacceptable threshold. This fault is detected while running POST.\n  Refer to %s for more information."
436200c5a5aShuestonmsgid "SCF-8001-4X.response"
437200c5a5aShuestonmsgstr "The memory associated with the memory bank containing the errors is deconfigured.\n"
438200c5a5aShuestonmsgid "SCF-8001-4X.impact"
439200c5a5aShuestonmsgstr "POST is restarted after the memory associated with the memory bank has been deconfigured.\n"
440200c5a5aShuestonmsgid "SCF-8001-4X.action"
441200c5a5aShuestonmsgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
442200c5a5aShueston#
443200c5a5aShueston# code: SCF-8001-9S
444200c5a5aShueston# keys: fault.chassis.SPARC-Enterprise.asic.flp.fe
445200c5a5aShueston#
446200c5a5aShuestonmsgid "SCF-8001-9S.type"
447200c5a5aShuestonmsgstr "Fault"
448200c5a5aShuestonmsgid "SCF-8001-9S.severity"
449200c5a5aShuestonmsgstr "Critical"
450200c5a5aShuestonmsgid "SCF-8001-9S.description"
451200c5a5aShuestonmsgstr "A fatal error has occurred within a FLP chip.\n  Refer to %s for more information."
452200c5a5aShuestonmsgid "SCF-8001-9S.response"
453200c5a5aShuestonmsgstr "A single domain will be reset and the IO Channel associated with the\nFLP chip will be deconfigured during recovery.\n"
454200c5a5aShuestonmsgid "SCF-8001-9S.impact"
455200c5a5aShuestonmsgstr "Domain will be reset.\n"
456200c5a5aShuestonmsgid "SCF-8001-9S.action"
457200c5a5aShuestonmsgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
458200c5a5aShueston#
459200c5a5aShueston# code: SCF-8001-AA
460200c5a5aShueston# keys: fault.chassis.SPARC-Enterprise.asic.flp.ce
461200c5a5aShueston#
462200c5a5aShuestonmsgid "SCF-8001-AA.type"
463200c5a5aShuestonmsgstr "Fault"
464200c5a5aShuestonmsgid "SCF-8001-AA.severity"
465200c5a5aShuestonmsgstr "Major"
466200c5a5aShuestonmsgid "SCF-8001-AA.description"
467200c5a5aShuestonmsgstr "The number of correctable errors associated with a FLP chip has exceeded an\nacceptable threshold.\n  Refer to %s for more information."
468200c5a5aShuestonmsgid "SCF-8001-AA.response"
469200c5a5aShuestonmsgstr "The IO Channel associated with the FLP chip will be deconfigured after the platform is power \ncycled or after the domain reboots or after a Dynamic Reconfiguration operation is performed.\n"
470200c5a5aShuestonmsgid "SCF-8001-AA.impact"
471200c5a5aShuestonmsgstr "No immediate impact. The IO Channel associated with the FLP chip will be deconfigured after the \nplatform is power cycled or after the domain reboots or after a Dynamic Reconfiguration operation is \nperformed.\n"
472200c5a5aShuestonmsgid "SCF-8001-AA.action"
473200c5a5aShuestonmsgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
474200c5a5aShueston#
475200c5a5aShueston# code: SCF-8001-KC
476200c5a5aShueston# keys: upset.chassis.SPARC-Enterprise.io.disk.boot
477200c5a5aShueston#
478200c5a5aShuestonmsgid "SCF-8001-KC.type"
479200c5a5aShuestonmsgstr "upset"
480200c5a5aShuestonmsgid "SCF-8001-KC.severity"
481200c5a5aShuestonmsgstr "Critical"
482200c5a5aShuestonmsgid "SCF-8001-KC.description"
483*756113e7SDan McDonaldmsgstr "Failure to boot illumos on a domain via an internal disk drive on the SAS controller.\n  Refer to %s for more information."
484200c5a5aShuestonmsgid "SCF-8001-KC.response"
485200c5a5aShuestonmsgstr "Nothing is deconfigured.\n"
486200c5a5aShuestonmsgid "SCF-8001-KC.impact"
487200c5a5aShuestonmsgstr "The domain drops to the OpenBoot PROM 'ok' prompt.\n"
488200c5a5aShuestonmsgid "SCF-8001-KC.action"
489200c5a5aShuestonmsgstr "The platform administrator should investigate the cause of the boot problem\nand schedule a service action, if necessary.\nPlease consult the detail section of the knowledge article for additional information.\n"
490200c5a5aShueston#
491200c5a5aShueston# code: SCF-8001-LQ
492200c5a5aShueston# keys: fault.chassis.SPARC-Enterprise.if.fe-ioc-flp
493200c5a5aShueston#
494200c5a5aShuestonmsgid "SCF-8001-LQ.type"
495200c5a5aShuestonmsgstr "Fault"
496200c5a5aShuestonmsgid "SCF-8001-LQ.severity"
497200c5a5aShuestonmsgstr "Critical"
498200c5a5aShuestonmsgid "SCF-8001-LQ.description"
499200c5a5aShuestonmsgstr "A fatal error occurred on the interface between an IOC chip and a FLP chip.\n  Refer to %s for more information."
500200c5a5aShuestonmsgid "SCF-8001-LQ.response"
501200c5a5aShuestonmsgstr "The IO Channel associated with the FLP chip will be deconfigured after the domain\nusing the IO Channel is reset.\n"
502200c5a5aShuestonmsgid "SCF-8001-LQ.impact"
503200c5a5aShuestonmsgstr "The domain using the IO Channel associated with the FLP chip is reset. The IO Channel will\ndeconfigured after the domain is reset.\n"
504200c5a5aShuestonmsgid "SCF-8001-LQ.action"
505200c5a5aShuestonmsgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
506200c5a5aShueston#
507200c5a5aShueston# code: SCF-8001-ME
508200c5a5aShueston# keys: fault.chassis.SPARC-Enterprise.asic.ioc.fe
509200c5a5aShueston#
510200c5a5aShuestonmsgid "SCF-8001-ME.type"
511200c5a5aShuestonmsgstr "Fault"
512200c5a5aShuestonmsgid "SCF-8001-ME.severity"
513200c5a5aShuestonmsgstr "Critical"
514200c5a5aShuestonmsgid "SCF-8001-ME.description"
515200c5a5aShuestonmsgstr "A fatal error was detected within an IOC chip.\n  Refer to %s for more information."
516200c5a5aShuestonmsgid "SCF-8001-ME.response"
517200c5a5aShuestonmsgstr "The IOC chip (two IO Channels) will be deconfigured after the domains (one or two domains) using\nthe IOC chip are reset.\n"
518200c5a5aShuestonmsgid "SCF-8001-ME.impact"
519200c5a5aShuestonmsgstr "The domains (one or two domains) using the IOC chip are reset. The IOC chip (two IO Channels) will be \ndeconfigured after the domains are reset.\n"
520200c5a5aShuestonmsgid "SCF-8001-ME.action"
521200c5a5aShuestonmsgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
522200c5a5aShueston#
523200c5a5aShueston# code: SCF-8001-NJ
524200c5a5aShueston# keys: upset.chassis.SPARC-Enterprise.asic.ioc.fe-tmo-dma
525200c5a5aShueston#
526200c5a5aShuestonmsgid "SCF-8001-NJ.type"
527200c5a5aShuestonmsgstr "Upset"
528200c5a5aShuestonmsgid "SCF-8001-NJ.severity"
529200c5a5aShuestonmsgstr "Critical"
530200c5a5aShuestonmsgid "SCF-8001-NJ.description"
531200c5a5aShuestonmsgstr "A fatal DMA master timeout detected by an IOC chip.\n  Refer to %s for more information."
532200c5a5aShuestonmsgid "SCF-8001-NJ.response"
533200c5a5aShuestonmsgstr "The domains (one or two domains) using the IOC chip are reset. No components are deconfigured.\n"
534200c5a5aShuestonmsgid "SCF-8001-NJ.impact"
535200c5a5aShuestonmsgstr "The domains (one or two domains) using the IOC chip are reset.\n"
536200c5a5aShuestonmsgid "SCF-8001-NJ.action"
537200c5a5aShuestonmsgstr "The precise cause of the fault cannot be isolated. Please schedule a repair action.\nPlease consult the detail section of the knowledge article for additional information.\n"
538200c5a5aShueston#
539200c5a5aShueston# code: SCF-8001-P2
540200c5a5aShueston# keys: fault.chassis.SPARC-Enterprise.asic.ioc.ch.fe
541200c5a5aShueston#
542200c5a5aShuestonmsgid "SCF-8001-P2.type"
543200c5a5aShuestonmsgstr "Fault"
544200c5a5aShuestonmsgid "SCF-8001-P2.severity"
545200c5a5aShuestonmsgstr "Critical"
546200c5a5aShuestonmsgid "SCF-8001-P2.description"
547200c5a5aShuestonmsgstr "A fatal error was detected within an IOC chip. This fatal error affects only a single\nIO Channel.\n  Refer to %s for more information."
548200c5a5aShuestonmsgid "SCF-8001-P2.response"
549200c5a5aShuestonmsgstr "The IO Channel will be deconfigured after the domain is reset.\n"
550200c5a5aShuestonmsgid "SCF-8001-P2.impact"
551200c5a5aShuestonmsgstr "The domain using the IO Channel is reset. The IO Channel will be deconfigured after\nthe domain is reset.\n"
552200c5a5aShuestonmsgid "SCF-8001-P2.action"
553200c5a5aShuestonmsgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information\n"
554200c5a5aShueston#
555200c5a5aShueston# code: SCF-8001-QX
556200c5a5aShueston# keys: fault.chassis.SPARC-Enterprise.asic.ioc.ch.leaf.fe
557200c5a5aShueston#
558200c5a5aShuestonmsgid "SCF-8001-QX.type"
559200c5a5aShuestonmsgstr "Fault"
560200c5a5aShuestonmsgid "SCF-8001-QX.severity"
561200c5a5aShuestonmsgstr "Critical"
562200c5a5aShuestonmsgid "SCF-8001-QX.description"
563200c5a5aShuestonmsgstr "A fatal error was detected within an IOC chip. The fatal error affects only one leaf within\nan IO Channel (1/2 an IO Channel).\n  Refer to %s for more information."
564200c5a5aShuestonmsgid "SCF-8001-QX.response"
565200c5a5aShuestonmsgstr "The IO Channel leaf (1/2 an IO Channel) will be deconfigured after the domain using the IO\nChannel is reset.\n"
566200c5a5aShuestonmsgid "SCF-8001-QX.impact"
567200c5a5aShuestonmsgstr "The domain using the IO Channel leaf is reset. The IO Channel leaf (1/2 an IO Channel) will be\ndeconfigured after the domain is reset.\n"
568200c5a5aShuestonmsgid "SCF-8001-QX.action"
569200c5a5aShuestonmsgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
570200c5a5aShueston#
571200c5a5aShueston# code: SCF-8001-RP
572200c5a5aShueston# keys: fault.chassis.SPARC-Enterprise.io.pciex.card.fe
573200c5a5aShueston#
574200c5a5aShuestonmsgid "SCF-8001-RP.type"
575200c5a5aShuestonmsgstr "Fault"
576200c5a5aShuestonmsgid "SCF-8001-RP.severity"
577200c5a5aShuestonmsgstr "Critical"
578200c5a5aShuestonmsgid "SCF-8001-RP.description"
579200c5a5aShuestonmsgstr "A fatal error was detected on a PCI-Express card in a PCI slot.\n  Refer to %s for more information."
580200c5a5aShuestonmsgid "SCF-8001-RP.response"
581200c5a5aShuestonmsgstr "The PCI-Express card is deconfigured.\n"
582200c5a5aShuestonmsgid "SCF-8001-RP.impact"
583200c5a5aShuestonmsgstr "The domain using the PCI slot is reset.\n"
584200c5a5aShuestonmsgid "SCF-8001-RP.action"
585200c5a5aShuestonmsgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
586200c5a5aShueston#
587200c5a5aShueston# code: SCF-8001-SA
588200c5a5aShueston# keys: fault.chassis.SPARC-Enterprise.io.pci.card.fe
589200c5a5aShueston#
590200c5a5aShuestonmsgid "SCF-8001-SA.type"
591200c5a5aShuestonmsgstr "Fault"
592200c5a5aShuestonmsgid "SCF-8001-SA.severity"
593200c5a5aShuestonmsgstr "Critical"
594200c5a5aShuestonmsgid "SCF-8001-SA.description"
595200c5a5aShuestonmsgstr "A fatal error was detected on a PCI-X card in a PCI slot.\n  Refer to %s for more information."
596200c5a5aShuestonmsgid "SCF-8001-SA.response"
597200c5a5aShuestonmsgstr "The PCI-X card is deconfigured.\n"
598200c5a5aShuestonmsgid "SCF-8001-SA.impact"
599200c5a5aShuestonmsgstr "The domain using the PCI slot is reset.\n"
600200c5a5aShuestonmsgid "SCF-8001-SA.action"
601200c5a5aShuestonmsgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
602200c5a5aShueston#
603200c5a5aShueston# code: SCF-8001-TS
604200c5a5aShueston# keys: fault.chassis.SPARC-Enterprise.io.pciex.bridge.fe
605200c5a5aShueston#
606200c5a5aShuestonmsgid "SCF-8001-TS.type"
607200c5a5aShuestonmsgstr "Fault"
608200c5a5aShuestonmsgid "SCF-8001-TS.severity"
609200c5a5aShuestonmsgstr "Critical"
610200c5a5aShuestonmsgid "SCF-8001-TS.description"
611200c5a5aShuestonmsgstr "A fatal error was detected within a PCIe/PCI-X bridge chip.\n  Refer to %s for more information."
612200c5a5aShuestonmsgid "SCF-8001-TS.response"
613200c5a5aShuestonmsgstr "All internal I/O behind the PCIe/PCI-X bridge chip is deconfigured (if the\nPCIe/PCI-X bridge chip is located on an IOU or IOUA) or all the PCI-X slots \nin an I/O Boat are deconfigured (if the PCIe/PCI-X bridge chip is located on\nan I/O Boat).\n"
614200c5a5aShuestonmsgid "SCF-8001-TS.impact"
615200c5a5aShuestonmsgstr "The domain using the PCIe/PCI-X bridge chip is reset.\n"
616200c5a5aShuestonmsgid "SCF-8001-TS.action"
617200c5a5aShuestonmsgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
618200c5a5aShueston#
619200c5a5aShueston# code: SCF-8001-U5
620200c5a5aShueston# keys: fault.chassis.SPARC-Enterprise.io.pciex.switch.fe
621200c5a5aShueston#
622200c5a5aShuestonmsgid "SCF-8001-U5.type"
623200c5a5aShuestonmsgstr "Fault"
624200c5a5aShuestonmsgid "SCF-8001-U5.severity"
625200c5a5aShuestonmsgstr "Critical"
626200c5a5aShuestonmsgid "SCF-8001-U5.description"
627200c5a5aShuestonmsgstr "A fatal error was detected within a PCIe switch chip.\n  Refer to %s for more information."
628200c5a5aShuestonmsgid "SCF-8001-U5.response"
629200c5a5aShuestonmsgstr "All internal I/O behind the PCIe switch chip is deconfigured (if the PCIe switch chip\nis located on an IOU) or all the PCI-Express slots or PCI-X slots in an I/O Boat are \ndeconfigured (if the PCIe switch chip is located on an I/O Boat).\n"
630200c5a5aShuestonmsgid "SCF-8001-U5.impact"
631200c5a5aShuestonmsgstr "The domain using the PCIe switch chip is reset.\n"
632200c5a5aShuestonmsgid "SCF-8001-U5.action"
633200c5a5aShuestonmsgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
634200c5a5aShueston#
635200c5a5aShueston# code: SCF-8001-VY
636200c5a5aShueston# keys: fault.chassis.SPARC-Enterprise.io.pci.gbe.fe
637200c5a5aShueston#
638200c5a5aShuestonmsgid "SCF-8001-VY.type"
639200c5a5aShuestonmsgstr "Fault"
640200c5a5aShuestonmsgid "SCF-8001-VY.severity"
641200c5a5aShuestonmsgstr "Critical"
642200c5a5aShuestonmsgid "SCF-8001-VY.description"
643200c5a5aShuestonmsgstr "A fatal error was detected within a Gigabit Ethernet (GbE) controller.\n  Refer to %s for more information."
644200c5a5aShuestonmsgid "SCF-8001-VY.response"
645200c5a5aShuestonmsgstr "The Gigabit Ethernet (GbE) controller is deconfigured.\n"
646200c5a5aShuestonmsgid "SCF-8001-VY.impact"
647200c5a5aShuestonmsgstr "The domain using the Gigabit Ethernet (GbE) controller is reset.\n"
648200c5a5aShuestonmsgid "SCF-8001-VY.action"
649200c5a5aShuestonmsgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
650200c5a5aShueston#
651200c5a5aShueston# code: SCF-8001-W3
652200c5a5aShueston# keys: fault.chassis.SPARC-Enterprise.io.pci.sas.fe
653200c5a5aShueston#
654200c5a5aShuestonmsgid "SCF-8001-W3.type"
655200c5a5aShuestonmsgstr "Fault"
656200c5a5aShuestonmsgid "SCF-8001-W3.severity"
657200c5a5aShuestonmsgstr "Critical"
658200c5a5aShuestonmsgid "SCF-8001-W3.description"
659200c5a5aShuestonmsgstr "A fatal error was detected within a SAS (Serial Attached SCSI) controller.\n  Refer to %s for more information."
660200c5a5aShuestonmsgid "SCF-8001-W3.response"
661200c5a5aShuestonmsgstr "The internal SAS devices behind the SAS controller (internal HDDs, internal DVD drives, internal\ntape drives) are deconfigured.\n"
662200c5a5aShuestonmsgid "SCF-8001-W3.impact"
663200c5a5aShuestonmsgstr "The domain using the SAS controller is reset.\n"
664200c5a5aShuestonmsgid "SCF-8001-W3.action"
665200c5a5aShuestonmsgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
666200c5a5aShueston#
667200c5a5aShueston# code: SCF-8001-XH
668200c5a5aShueston# keys: fault.chassis.SPARC-Enterprise.if.se-ioc-flp
669200c5a5aShueston#
670200c5a5aShuestonmsgid "SCF-8001-XH.type"
671200c5a5aShuestonmsgstr "Fault"
672200c5a5aShuestonmsgid "SCF-8001-XH.severity"
673200c5a5aShuestonmsgstr "Major"
674200c5a5aShuestonmsgid "SCF-8001-XH.description"
675200c5a5aShuestonmsgstr "A non-fatal uncorrectable error occurred on the interface between an IOC chip and a FLP chip.\n  Refer to %s for more information."
676200c5a5aShuestonmsgid "SCF-8001-XH.response"
677200c5a5aShuestonmsgstr "The IO Channel corresponding to the FLP chip will be deconfigured after the platform is power cycled or \nafter the domain reboots or after a Dynamic Reconfiguration operation is performed.\n"
678200c5a5aShuestonmsgid "SCF-8001-XH.impact"
679200c5a5aShuestonmsgstr "The non-fatal uncorrectable error trap may cause the domain to panic. \nThe IO Channel corresponding to the FLP chip will be deconfigured after the platform is power cycled or \nafter the domain reboots or after a Dynamic Reconfiguration operation is performed.\n"
680200c5a5aShuestonmsgid "SCF-8001-XH.action"
681200c5a5aShuestonmsgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
682200c5a5aShueston#
683200c5a5aShueston# code: SCF-8001-YD
684200c5a5aShueston# keys: fault.chassis.SPARC-Enterprise.asic.ioc.ch.se
685200c5a5aShueston#
686200c5a5aShuestonmsgid "SCF-8001-YD.type"
687200c5a5aShuestonmsgstr "Fault"
688200c5a5aShuestonmsgid "SCF-8001-YD.severity"
689200c5a5aShuestonmsgstr "Major"
690200c5a5aShuestonmsgid "SCF-8001-YD.description"
691200c5a5aShuestonmsgstr "A non-fatal uncorrectable error was detected within an IOC chip. This error affects\na single IO Channel.\n  Refer to %s for more information."
692200c5a5aShuestonmsgid "SCF-8001-YD.response"
693200c5a5aShuestonmsgstr "The IO Channel will be deconfigured after the platform is power cycled or after the domain reboots or \nafter a Dynamic Reconfiguration operation is performed.\n"
694200c5a5aShuestonmsgid "SCF-8001-YD.impact"
695200c5a5aShuestonmsgstr "The non-fatal uncorrectable error trap may cause the domain to panic.  The IO Channel will be deconfigured \nafter the platform is power cycled or after the domain reboots or after a Dynamic Reconfiguration operation \nis performed.\n"
696200c5a5aShuestonmsgid "SCF-8001-YD.action"
697200c5a5aShuestonmsgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
698200c5a5aShueston#
699200c5a5aShueston# code: SCF-8002-0X
700200c5a5aShueston# keys: fault.chassis.SPARC-Enterprise.asic.ioc.ch.leaf.se
701200c5a5aShueston#
702200c5a5aShuestonmsgid "SCF-8002-0X.type"
703200c5a5aShuestonmsgstr "Fault"
704200c5a5aShuestonmsgid "SCF-8002-0X.severity"
705200c5a5aShuestonmsgstr "Major"
706200c5a5aShuestonmsgid "SCF-8002-0X.description"
707200c5a5aShuestonmsgstr "Non-fatal uncorrectable error was detected within an IOC chip. This error affects\na single IO Channel leaf (1/2 an IO Channel).\n  Refer to %s for more information."
708200c5a5aShuestonmsgid "SCF-8002-0X.response"
709200c5a5aShuestonmsgstr "The IO Channel leaf (1/2 an IO Channel) will be deconfigured after the platform is power cycled or \nafter the domain reboots or after a Dynamic Reconfiguration operation is performed.\n"
710200c5a5aShuestonmsgid "SCF-8002-0X.impact"
711200c5a5aShuestonmsgstr "The non-fatal uncorrectable error trap may cause the domain to panic. \nThe IO Channel leaf (1/2 an IO Channel) will be deconfigured after the platform is power cycled or \nafter the domain reboots or after a Dynamic Reconfiguration operation is performed.\n"
712200c5a5aShuestonmsgid "SCF-8002-0X.action"
713200c5a5aShuestonmsgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
714200c5a5aShueston#
715200c5a5aShueston# code: SCF-8002-12
716200c5a5aShueston# keys: fault.chassis.SPARC-Enterprise.asic.ioc.ch.leaf.se-no-credit-pci
717200c5a5aShueston#
718200c5a5aShuestonmsgid "SCF-8002-12.type"
719200c5a5aShuestonmsgstr "Fault"
720200c5a5aShuestonmsgid "SCF-8002-12.severity"
721200c5a5aShuestonmsgstr "Major"
722200c5a5aShuestonmsgid "SCF-8002-12.description"
723200c5a5aShuestonmsgstr "A non-fatal uncorrectable \"PCI-E card no-credit update\" error has been detected by an IOC chip.\n  Refer to %s for more information."
724200c5a5aShuestonmsgid "SCF-8002-12.response"
725200c5a5aShuestonmsgstr "The IO Channel leaf (1/2 an IO Channel) will be deconfigured after the platform is power cycled or \nafter the domain reboots or after a Dynamic Reconfiguration operation is performed.\n"
726200c5a5aShuestonmsgid "SCF-8002-12.impact"
727200c5a5aShuestonmsgstr "The non-fatal uncorrectable error trap may cause the domain to panic. \nThe IO Channel leaf (1/2 an IO Channel) will be deconfigured after the platform is power cycled or \nafter the domain reboots or after a Dynamic Reconfiguration operation is performed.\n"
728200c5a5aShuestonmsgid "SCF-8002-12.action"
729200c5a5aShuestonmsgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
730200c5a5aShueston#
731200c5a5aShueston# code: SCF-8002-2J
732200c5a5aShueston# keys: fault.chassis.SPARC-Enterprise.io.pciex.card.se
733200c5a5aShueston#
734200c5a5aShuestonmsgid "SCF-8002-2J.type"
735200c5a5aShuestonmsgstr "Fault"
736200c5a5aShuestonmsgid "SCF-8002-2J.severity"
737200c5a5aShuestonmsgstr "Major"
738200c5a5aShuestonmsgid "SCF-8002-2J.description"
739200c5a5aShuestonmsgstr "A non-fatal uncorrectable error occurred due to a PCI-Express card in a PCI-Express slot.\n  Refer to %s for more information."
740200c5a5aShuestonmsgid "SCF-8002-2J.response"
741200c5a5aShuestonmsgstr "The PCI-Express slot will be deconfigured after the platform is power cycled or \nafter the domain reboots or after a Dynamic Reconfiguration operation is performed.\n"
742200c5a5aShuestonmsgid "SCF-8002-2J.impact"
743200c5a5aShuestonmsgstr "The non-fatal uncorrectable error trap may cause the domain to panic. \nThe PCI-Express slot will be deconfigured after the platform is power cycled or \nafter the domain reboots or after a Dynamic Reconfiguration operation is performed.\n"
744200c5a5aShuestonmsgid "SCF-8002-2J.action"
745200c5a5aShuestonmsgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
746200c5a5aShueston#
747200c5a5aShueston# code: SCF-8002-3E
748200c5a5aShueston# keys: fault.chassis.SPARC-Enterprise.io.pci.card.se
749200c5a5aShueston#
750200c5a5aShuestonmsgid "SCF-8002-3E.type"
751200c5a5aShuestonmsgstr "Fault"
752200c5a5aShuestonmsgid "SCF-8002-3E.severity"
753200c5a5aShuestonmsgstr "Major"
754200c5a5aShuestonmsgid "SCF-8002-3E.description"
755200c5a5aShuestonmsgstr "A non-fatal uncorrectable error occcurred due to a PCI-X card in a PCI slot.\n  Refer to %s for more information."
756200c5a5aShuestonmsgid "SCF-8002-3E.response"
757200c5a5aShuestonmsgstr "The PCI-X slot will be deconfigured after the platform is power cycled or \nafter the domain reboots or after a Dynamic Reconfiguration operation is performed.\n"
758200c5a5aShuestonmsgid "SCF-8002-3E.impact"
759200c5a5aShuestonmsgstr "The non-fatal uncorrectable error trap may cause the domain to panic. \nThe PCI-X slot will be deconfigured after the platform is power cycled or \nafter the domain reboots or after a Dynamic Reconfiguration operation is performed.\n"
760200c5a5aShuestonmsgid "SCF-8002-3E.action"
761200c5a5aShuestonmsgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
762200c5a5aShueston#
763200c5a5aShueston# code: SCF-8002-4Q
764200c5a5aShueston# keys: fault.chassis.SPARC-Enterprise.io.pciex.bridge.se
765200c5a5aShueston#
766200c5a5aShuestonmsgid "SCF-8002-4Q.type"
767200c5a5aShuestonmsgstr "Fault"
768200c5a5aShuestonmsgid "SCF-8002-4Q.severity"
769200c5a5aShuestonmsgstr "Major"
770200c5a5aShuestonmsgid "SCF-8002-4Q.description"
771200c5a5aShuestonmsgstr "A non-fatal uncorrectable error was detected within a PCIe/PCI-X bridge chip.\n  Refer to %s for more information."
772200c5a5aShuestonmsgid "SCF-8002-4Q.response"
773200c5a5aShuestonmsgstr "All internal I/O behind the PCIe/PCI-X bridge chip is deconfigured (if the\nPCIe/PCI-X bridge chip is located on an IOU or IOUA) or all the PCI-X slots \nin an I/O Boat are deconfigured (if the PCIe/PCI-X bridge chip is located on\nan I/O Boat). The deconfiguration will take place after the platform is power cycled or \nafter the domain reboots or after a Dynamic Reconfiguration operation is performed.\n"
774200c5a5aShuestonmsgid "SCF-8002-4Q.impact"
775200c5a5aShuestonmsgstr "The non-fatal uncorrectable error trap may cause the domain to panic. \nAll internal I/O behind the PCIe/PCI-X bridge chip is deconfigured (if the\nPCIe/PCI-X bridge chip is located on an IOU or IOUA) or all the PCI-X slots \nin an I/O Boat are deconfigured (if the PCIe/PCI-X bridge chip is located on\nan I/O Boat). The deconfiguration will take place after the platform is power cycled or \nafter the domain reboots or after a Dynamic Reconfiguration operation is performed.\n"
776200c5a5aShuestonmsgid "SCF-8002-4Q.action"
777200c5a5aShuestonmsgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
778200c5a5aShueston#
779200c5a5aShueston# code: SCF-8002-5C
780200c5a5aShueston# keys: fault.chassis.SPARC-Enterprise.io.pciex.switch.se
781200c5a5aShueston#
782200c5a5aShuestonmsgid "SCF-8002-5C.type"
783200c5a5aShuestonmsgstr "Fault"
784200c5a5aShuestonmsgid "SCF-8002-5C.severity"
785200c5a5aShuestonmsgstr "Major"
786200c5a5aShuestonmsgid "SCF-8002-5C.description"
787200c5a5aShuestonmsgstr "A non-fatal uncorrectable error was detected within a PCIe switch chip.\n  Refer to %s for more information."
788200c5a5aShuestonmsgid "SCF-8002-5C.response"
789200c5a5aShuestonmsgstr "All internal I/O behind the PCIe switch chip is deconfigured (if the PCIe switch chip\nis located on an IOU) or all the PCI-Express slots or PCI-X slots in an I/O Boat are \ndeconfigured (if the PCIe switch chip is located on an I/O Boat). The deconfiguration\nwill take place after the platform is power cycled or after the domain reboots or after a \nDynamic Reconfiguration operation is performed.\n"
790200c5a5aShuestonmsgid "SCF-8002-5C.impact"
791200c5a5aShuestonmsgstr "The non-fatal uncorrectable error trap may cause the domain to panic. \nAll internal I/O behind the PCIe switch chip is deconfigured (if the PCIe switch chip\nis located on an IOU) or all the PCI-Express slots or PCI-X slots in an I/O Boat are \ndeconfigured (if the PCIe switch chip is located on an I/O Boat). The deconfiguration\nwill take place after the platform is power cycled or after the domain reboots or after a \nDynamic Reconfiguration operation is performed.\n"
792200c5a5aShuestonmsgid "SCF-8002-5C.action"
793200c5a5aShuestonmsgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
794200c5a5aShueston#
795200c5a5aShueston# code: SCF-8002-6R
796200c5a5aShueston# keys: fault.chassis.SPARC-Enterprise.if.ce-ioc-flp
797200c5a5aShueston#
798200c5a5aShuestonmsgid "SCF-8002-6R.type"
799200c5a5aShuestonmsgstr "Fault"
800200c5a5aShuestonmsgid "SCF-8002-6R.severity"
801200c5a5aShuestonmsgstr "Major"
802200c5a5aShuestonmsgid "SCF-8002-6R.description"
803200c5a5aShuestonmsgstr "The number of correctable errors on the interface between an IOC chip and a FLP chip has exceeded \nan acceptable threshold.\n  Refer to %s for more information."
804200c5a5aShuestonmsgid "SCF-8002-6R.response"
805200c5a5aShuestonmsgstr "The IO Channel that is associated with the FLP chip will be deconfigured after the platform is power \ncycled or after the domain reboots or after a Dynamic Reconfiguration operation is performed.\n"
806200c5a5aShuestonmsgid "SCF-8002-6R.impact"
807200c5a5aShuestonmsgstr "No immediate impact. The IO Channel that is associated with the FLP chip will be deconfigured after the \nplatform is power cycled or after the domain reboots or after a Dynamic Reconfiguration operation is \nperformed.\n"
808200c5a5aShuestonmsgid "SCF-8002-6R.action"
809200c5a5aShuestonmsgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
810200c5a5aShueston#
811200c5a5aShueston# code: SCF-8002-74
812200c5a5aShueston# keys: fault.chassis.SPARC-Enterprise.asic.ioc.ch.ce
813200c5a5aShueston#
814200c5a5aShuestonmsgid "SCF-8002-74.type"
815200c5a5aShuestonmsgstr "Fault"
816200c5a5aShuestonmsgid "SCF-8002-74.severity"
817200c5a5aShuestonmsgstr "Major"
818200c5a5aShuestonmsgid "SCF-8002-74.description"
819200c5a5aShuestonmsgstr "The number of correctable errors within a IOC Chip has exceeded an acceptable threshold. This fault\naffects a single IO Channel.\n  Refer to %s for more information."
820200c5a5aShuestonmsgid "SCF-8002-74.response"
821200c5a5aShuestonmsgstr "The IO Channel is deconfigured after the platform is power cycled or after the domain reboots or after a \nDynamic Reconfiguration operation is performed.\n"
822200c5a5aShuestonmsgid "SCF-8002-74.impact"
823200c5a5aShuestonmsgstr "No immediate impact. The IO Channel is deconfigured after the platform is power cycled or after the \ndomain reboots or after a Dynamic Reconfiguration operation is performed.\n"
824200c5a5aShuestonmsgid "SCF-8002-74.action"
825200c5a5aShuestonmsgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
826200c5a5aShueston#
827200c5a5aShueston# code: SCF-8002-8D
828200c5a5aShueston# keys: fault.chassis.SPARC-Enterprise.asic.ioc.ch.leaf.ce
829200c5a5aShueston#
830200c5a5aShuestonmsgid "SCF-8002-8D.type"
831200c5a5aShuestonmsgstr "Fault"
832200c5a5aShuestonmsgid "SCF-8002-8D.severity"
833200c5a5aShuestonmsgstr "Major"
834200c5a5aShuestonmsgid "SCF-8002-8D.description"
835200c5a5aShuestonmsgstr "The number of correctable errors within a IOC Chip has exceeded an acceptable threshold. This fault\naffects a single IO Channel leaf (1/2 an IO Channel).\n  Refer to %s for more information."
836200c5a5aShuestonmsgid "SCF-8002-8D.response"
837200c5a5aShuestonmsgstr "The IO Channel leaf (1/2 an IO Channel) is deconfigured after the platform is power cycled or after \nthe domain reboots or after a Dynamic Reconfiguration operation is performed.\n"
838200c5a5aShuestonmsgid "SCF-8002-8D.impact"
839200c5a5aShuestonmsgstr "No immediate impact. The IO Channel leaf (1/2 an IO Channel) is deconfigured after the platform is \npower cycled or after the domain reboots or after a Dynamic Reconfiguration operation is performed.\n"
840200c5a5aShuestonmsgid "SCF-8002-8D.action"
841200c5a5aShuestonmsgstr "Schedule a repair action to replace the affected Field Replaceable Unit (FRU),\nthe identity of which can be determined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
842200c5a5aShueston#
843200c5a5aShueston# code: SCF-8002-9H
844200c5a5aShueston# keys: upset.chassis.SPARC-Enterprise.asic.ioc.ch.boot
845200c5a5aShueston#
846200c5a5aShuestonmsgid "SCF-8002-9H.type"
847200c5a5aShuestonmsgstr "Upset"
848200c5a5aShuestonmsgid "SCF-8002-9H.severity"
849200c5a5aShuestonmsgstr "Critical"
850200c5a5aShuestonmsgid "SCF-8002-9H.description"
851*756113e7SDan McDonaldmsgstr "Failure to boot illumos on a domain using a device on an IO Channel.\n  Refer to %s for more information."
852200c5a5aShuestonmsgid "SCF-8002-9H.response"
853200c5a5aShuestonmsgstr "Nothing is deconfigured.\n"
854200c5a5aShuestonmsgid "SCF-8002-9H.impact"
855200c5a5aShuestonmsgstr "The domain drops to the OpenBoot PROM 'ok' prompt.\n"
856200c5a5aShuestonmsgid "SCF-8002-9H.action"
857200c5a5aShuestonmsgstr "The platform administrator should investigate the cause of the boot problem\nand schedule a service action, if necessary. Please consult the detail section of the \nknowledge article for additional information.\n"
858200c5a5aShueston#
859200c5a5aShueston# code: SCF-8002-A3
860200c5a5aShueston# keys: upset.chassis.SPARC-Enterprise.asic.ioc.ch.leaf.boot
861200c5a5aShueston#
862200c5a5aShuestonmsgid "SCF-8002-A3.type"
863200c5a5aShuestonmsgstr "Upset"
864200c5a5aShuestonmsgid "SCF-8002-A3.severity"
865200c5a5aShuestonmsgstr "Critical"
866200c5a5aShuestonmsgid "SCF-8002-A3.description"
867*756113e7SDan McDonaldmsgstr "Failure to boot illumos on a domain using a device on IO Channel leaf (1/2 an IO Channel).\n  Refer to %s for more information."
868200c5a5aShuestonmsgid "SCF-8002-A3.response"
869200c5a5aShuestonmsgstr "Nothing is deconfigured.\n"
870200c5a5aShuestonmsgid "SCF-8002-A3.impact"
871200c5a5aShuestonmsgstr "The domain drops to the OpenBoot PROM 'ok' prompt.\n"
872200c5a5aShuestonmsgid "SCF-8002-A3.action"
873200c5a5aShuestonmsgstr "The platform administrator should investigate the cause of the boot problem\nand schedule a service action, if necessary. Please consult the detail section of the \nknowledge article for additional information.\n"
874200c5a5aShueston#
875200c5a5aShueston# code: SCF-8002-CY
876200c5a5aShueston# keys: upset.chassis.SPARC-Enterprise.io.pci.gbe.boot
877200c5a5aShueston#
878200c5a5aShuestonmsgid "SCF-8002-CY.type"
879200c5a5aShuestonmsgstr "Upset"
880200c5a5aShuestonmsgid "SCF-8002-CY.severity"
881200c5a5aShuestonmsgstr "Critical"
882200c5a5aShuestonmsgid "SCF-8002-CY.description"
883*756113e7SDan McDonaldmsgstr "Failure to boot illumos on a domain via GbE.\n  Refer to %s for more information."
884200c5a5aShuestonmsgid "SCF-8002-CY.response"
885200c5a5aShuestonmsgstr "Nothing is deconfigured.\n"
886200c5a5aShuestonmsgid "SCF-8002-CY.impact"
887200c5a5aShuestonmsgstr "The domain drops to the OpenBoot PROM 'ok' prompt.\n"
888200c5a5aShuestonmsgid "SCF-8002-CY.action"
889200c5a5aShuestonmsgstr "The platform administrator should investigate the cause of the boot\nproblem and schedule a service action, if necessary.\nPlease consult the detail section of the knowledge article for additional information.\n"
890200c5a5aShueston#
891200c5a5aShueston# code: SCF-8002-D5
892200c5a5aShueston# keys: upset.chassis.SPARC-Enterprise.io.pci.card.boot
893200c5a5aShueston#
894200c5a5aShuestonmsgid "SCF-8002-D5.type"
895200c5a5aShuestonmsgstr "Upset"
896200c5a5aShuestonmsgid "SCF-8002-D5.severity"
897200c5a5aShuestonmsgstr "Critical"
898200c5a5aShuestonmsgid "SCF-8002-D5.description"
899*756113e7SDan McDonaldmsgstr "Failure to boot illumos on a domain using a device in a PCI-X slot.\n  Refer to %s for more information."
900200c5a5aShuestonmsgid "SCF-8002-D5.response"
901200c5a5aShuestonmsgstr "Nothing is deconfigured.\n"
902200c5a5aShuestonmsgid "SCF-8002-D5.impact"
903200c5a5aShuestonmsgstr "The domain drops to the OpenBoot PROM 'ok' prompt\n"
904200c5a5aShuestonmsgid "SCF-8002-D5.action"
905200c5a5aShuestonmsgstr "The platform administrator should investigate the cause of the boot\nproblem and schedule a service action, if necessary.\nPlease consult the detail section of the knowledge article for additional information.\n"
906200c5a5aShueston#
907200c5a5aShueston# code: SCF-8002-ES
908200c5a5aShueston# keys: upset.chassis.SPARC-Enterprise.io.pciex.card.boot
909200c5a5aShueston#
910200c5a5aShuestonmsgid "SCF-8002-ES.type"
911200c5a5aShuestonmsgstr "Upset"
912200c5a5aShuestonmsgid "SCF-8002-ES.severity"
913200c5a5aShuestonmsgstr "Critical"
914200c5a5aShuestonmsgid "SCF-8002-ES.description"
915*756113e7SDan McDonaldmsgstr "Failure to boot illumos on a domain using a device in a PCI-Express slot.\n  Refer to %s for more information."
916200c5a5aShuestonmsgid "SCF-8002-ES.response"
917200c5a5aShuestonmsgstr "Nothing is deconfigured.\n"
918200c5a5aShuestonmsgid "SCF-8002-ES.impact"
919200c5a5aShuestonmsgstr "The domain drops to the OpenBoot PROM 'ok' prompt.\n"
920200c5a5aShuestonmsgid "SCF-8002-ES.action"
921200c5a5aShuestonmsgstr "The platform administrator should investigate the cause of the boot\nproblem and schedule a service action, if necessary.\nPlease consult the detail section of the knowledge article for additional information.\n"
922200c5a5aShueston#
923200c5a5aShueston# code: SCF-8002-FA
924200c5a5aShueston# keys: upset.chassis.SPARC-Enterprise.io.pciex.bridge.boot
925200c5a5aShueston#
926200c5a5aShuestonmsgid "SCF-8002-FA.type"
927200c5a5aShuestonmsgstr "Upset"
928200c5a5aShuestonmsgid "SCF-8002-FA.severity"
929200c5a5aShuestonmsgstr "Critical"
930200c5a5aShuestonmsgid "SCF-8002-FA.description"
931*756113e7SDan McDonaldmsgstr "Failure to boot illumos on a domain using a device behind a PCI-Express/PCI-X \nbridge chip. This includes the PCI-X slot and internal I/O on an IOU (if the\nPCI-Express/PCI-X bridge is located on an IOU or IOUA) and the PCI-X slots of\nan I/O Boat (if the PCI-Express/PCI-X bridge is located on an I/O Boat).\n  Refer to %s for more information."
932200c5a5aShuestonmsgid "SCF-8002-FA.response"
933200c5a5aShuestonmsgstr "Nothing is deconfigured.\n"
934200c5a5aShuestonmsgid "SCF-8002-FA.impact"
935200c5a5aShuestonmsgstr "The domain drops to the OpenBoot PROM 'ok' prompt.\n"
936200c5a5aShuestonmsgid "SCF-8002-FA.action"
937200c5a5aShuestonmsgstr "The platform administrator should investigate the cause of the boot problem\nand schedule a service action, if necessary.\nPlease consult the detail section of the knowledge article for additional information.\n"
938200c5a5aShueston#
939200c5a5aShueston# code: SCF-8002-GP
940200c5a5aShueston# keys: upset.chassis.SPARC-Enterprise.io.pciex.switch.boot
941200c5a5aShueston#
942200c5a5aShuestonmsgid "SCF-8002-GP.type"
943200c5a5aShuestonmsgstr "upset"
944200c5a5aShuestonmsgid "SCF-8002-GP.severity"
945200c5a5aShuestonmsgstr "Critical"
946200c5a5aShuestonmsgid "SCF-8002-GP.description"
947*756113e7SDan McDonaldmsgstr "Failure to boot illumos on a domain using a device behind a PCI-Express switch chip.\nThis includes PCI-X slot and internal I/O devices (if the PCI-Express switch chip \nis located on an IOU), and the PCI-Express slots and PCI-X slots on an I/O Boat\n(if the PCI-Express switch chip is located on an I/O Boat).\n  Refer to %s for more information."
948200c5a5aShuestonmsgid "SCF-8002-GP.response"
949200c5a5aShuestonmsgstr "Nothing is deconfigured.\n"
950200c5a5aShuestonmsgid "SCF-8002-GP.impact"
951200c5a5aShuestonmsgstr "The domain drops to the OpenBoot PROM 'ok' prompt.\n"
952200c5a5aShuestonmsgid "SCF-8002-GP.action"
953200c5a5aShuestonmsgstr "The platform administrator should investigate the cause of the boot problem\nand schedule a service action, if necessary.\nPlease consult the detail section of the knowledge article for additional information.\n"
954200c5a5aShueston#
955200c5a5aShueston# code: SCF-8002-HE
956200c5a5aShueston# keys: upset.chassis.SPARC-Enterprise.io.pci.sas.boot
957200c5a5aShueston#
958200c5a5aShuestonmsgid "SCF-8002-HE.type"
959200c5a5aShuestonmsgstr "Upset"
960200c5a5aShuestonmsgid "SCF-8002-HE.severity"
961200c5a5aShuestonmsgstr "Critical"
962200c5a5aShuestonmsgid "SCF-8002-HE.description"
963*756113e7SDan McDonaldmsgstr "Failure to boot illumos on a domain using an internal SAS (Serial Attached\nSCSI) device. This includes the internal hard drives and the internal DVD drives\nand the internal tape drives.\n  Refer to %s for more information."
964200c5a5aShuestonmsgid "SCF-8002-HE.response"
965200c5a5aShuestonmsgstr "Nothing is deconfigured.\n"
966200c5a5aShuestonmsgid "SCF-8002-HE.impact"
967200c5a5aShuestonmsgstr "The domain drops to the OpenBoot PROM 'ok' prompt.\n"
968200c5a5aShuestonmsgid "SCF-8002-HE.action"
969200c5a5aShuestonmsgstr "The platform administrator should investigate the cause of the boot\nproblem and schedule a service action, if necessary.\nPlease consult the detail section of the knowledge article for additional information.\n"
970200c5a5aShueston#
971200c5a5aShueston# code: SCF-8002-JJ
972200c5a5aShueston# keys: fault.chassis.jtag.device
973200c5a5aShueston#
974200c5a5aShuestonmsgid "SCF-8002-JJ.type"
975200c5a5aShuestonmsgstr "Fault"
976200c5a5aShuestonmsgid "SCF-8002-JJ.severity"
977200c5a5aShuestonmsgstr "Critical"
978200c5a5aShuestonmsgid "SCF-8002-JJ.description"
979200c5a5aShuestonmsgstr "JTAG read or write failure to a specific chip.\n  Refer to %s for more information."
980200c5a5aShuestonmsgid "SCF-8002-JJ.response"
981200c5a5aShuestonmsgstr "The resources associated with the chip will be deconfigured. Please consult the detail section \nof the knowledge article for additional information.\n"
982200c5a5aShuestonmsgid "SCF-8002-JJ.impact"
983200c5a5aShuestonmsgstr "The platform may be reset or a domain may be reset. The platform may be unable to restart.\nPlease consult the detail section of the knowledge article for additional information.\n"
984200c5a5aShuestonmsgid "SCF-8002-JJ.action"
985200c5a5aShuestonmsgstr "The platform administrator should schedule a service action to replace\nthe affected Field Replaceable Unit (FRU), the identity of which can be\ndetermined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
986200c5a5aShueston#
987200c5a5aShueston# code: SCF-8002-K2
988200c5a5aShueston# keys: fault.chassis.jtag.device-internal
989200c5a5aShueston#
990200c5a5aShuestonmsgid "SCF-8002-K2.type"
991200c5a5aShuestonmsgstr "Fault"
992200c5a5aShuestonmsgid "SCF-8002-K2.severity"
993200c5a5aShuestonmsgstr "Critical"
994200c5a5aShuestonmsgid "SCF-8002-K2.description"
995200c5a5aShuestonmsgstr "JTAG access failure to a specific chip when attempting a reconfiguration operation.\nPlease consult the detail section of the knowledge article for additional information.\n  Refer to %s for more information."
996200c5a5aShuestonmsgid "SCF-8002-K2.response"
997200c5a5aShuestonmsgstr "The resources associated with the chip will be deconfigured. Please consult the detail section of \nthe knowledge article for additional information.\n"
998200c5a5aShuestonmsgid "SCF-8002-K2.impact"
999200c5a5aShuestonmsgstr "The platform may be reset or a domain may be reset. The platform may become unbootable.\nIt is also possible that some other problem may occur. Please consult the detail section of the \nknowledge article for additional information.\n"
1000200c5a5aShuestonmsgid "SCF-8002-K2.action"
1001200c5a5aShuestonmsgstr "The platform administrator should schedule a service action to replace\nthe affected Field Replaceable Unit (FRU), the identity of which can be\ndetermined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
1002200c5a5aShueston#
1003200c5a5aShueston# code: SCF-8002-LX
1004200c5a5aShueston# keys: fault.chassis.i2c.device
1005200c5a5aShueston#
1006200c5a5aShuestonmsgid "SCF-8002-LX.type"
1007200c5a5aShuestonmsgstr "Fault"
1008200c5a5aShuestonmsgid "SCF-8002-LX.severity"
1009200c5a5aShuestonmsgstr "Critical"
1010200c5a5aShuestonmsgid "SCF-8002-LX.description"
1011200c5a5aShuestonmsgstr "I2C access failure to an I2C device.\n  Refer to %s for more information."
1012200c5a5aShuestonmsgid "SCF-8002-LX.response"
1013200c5a5aShuestonmsgstr "The resources associated with the I2C device may deconfigured. The speed of all fans on the platform\nmay be raised. Please consult the detail section of the knowledge article for additional information.\n"
1014200c5a5aShuestonmsgid "SCF-8002-LX.impact"
1015200c5a5aShuestonmsgstr "It is possible that the platform will not be able to be be restarted. Please consult the detail section \nof the knowledge article for additional information.\n"
1016200c5a5aShuestonmsgid "SCF-8002-LX.action"
1017200c5a5aShuestonmsgstr "The platform administrator should schedule a service action to replace\nthe affected Field Replaceable Unit (FRU), the identity of which can be\ndetermined using fmdump -v -u EVENT_ID.\nPlease consult the detail section of the knowledge article for additional information.\n"
1018200c5a5aShueston#
1019200c5a5aShueston# code: SCF-8002-M4
1020200c5a5aShueston# keys: