1*12eb87fbSAlex Wilson# 2*12eb87fbSAlex Wilson# Copyright 2020 the University of Queensland 3*12eb87fbSAlex Wilson# Use is subject to license terms. 4*12eb87fbSAlex Wilson# 5*12eb87fbSAlex Wilson# This file and its contents are supplied under the terms of the 6*12eb87fbSAlex Wilson# Common Development and Distribution License ("CDDL"), version 1.0. 7*12eb87fbSAlex Wilson# You may only use this file in accordance with the terms of version 8*12eb87fbSAlex Wilson# 1.0 of the CDDL. 9*12eb87fbSAlex Wilson# 10*12eb87fbSAlex Wilson# A full copy of the text of the CDDL should have accompanied this 11*12eb87fbSAlex Wilson# source. A copy of the CDDL is also available via the Internet at 12*12eb87fbSAlex Wilson# http://www.illumos.org/license/CDDL. 13*12eb87fbSAlex Wilson# 14*12eb87fbSAlex Wilson 15*12eb87fbSAlex Wilson# 16*12eb87fbSAlex Wilson# code: NIC-8000-0Q 17*12eb87fbSAlex Wilson# keys: fault.io.nic.transceiver.notsupp 18*12eb87fbSAlex Wilson# 19*12eb87fbSAlex Wilsonmsgid "NIC-8000-0Q.type" 20*12eb87fbSAlex Wilsonmsgstr "Fault" 21*12eb87fbSAlex Wilsonmsgid "NIC-8000-0Q.severity" 22*12eb87fbSAlex Wilsonmsgstr "Critical" 23*12eb87fbSAlex Wilsonmsgid "NIC-8000-0Q.description" 24*12eb87fbSAlex Wilsonmsgstr "NIC transceiver module %<fault-list[0].resource.hc-specific.txr_index> (SFP/SFP+/QSFP+ etc.) in %<fault-list[0].resource.hc-specific.link-name> is of a type that is not supported. This may be due to an incompatible link type or speed. In some NICs, this may also be caused by enforcement of a vendor or part whitelist.\n\n NIC data link: %<fault-list[0].resource.hc-specific.link-name> (%<fault-list[0].resource.hc-specific.primary-mac-address>)\n Module vendor: %<fault-list[0].resource.hc-specific.vendor>\n Module part: %<fault-list[0].resource.part>\n Module serial: %<fault-list[0].resource.serial>\n\n Refer to %s for more information." 25*12eb87fbSAlex Wilsonmsgid "NIC-8000-0Q.response" 26*12eb87fbSAlex Wilsonmsgstr "The transceiver module has been disabled, and the network data link associated with it (%<fault-list[0].resource.hc-specific.link-name>) has been marked as down.\n" 27*12eb87fbSAlex Wilsonmsgid "NIC-8000-0Q.impact" 28*12eb87fbSAlex Wilsonmsgstr "No network traffic will pass through the data link or network interfaces associated with this transceiver slot.\n" 29*12eb87fbSAlex Wilsonmsgid "NIC-8000-0Q.action" 30*12eb87fbSAlex Wilsonmsgstr "Replace the transceiver module with one of a supported type.\n" 31*12eb87fbSAlex Wilson 32*12eb87fbSAlex Wilson# 33*12eb87fbSAlex Wilson# code: NIC-8000-1C 34*12eb87fbSAlex Wilson# keys: fault.io.nic.transceiver.whitelist 35*12eb87fbSAlex Wilson# 36*12eb87fbSAlex Wilsonmsgid "NIC-8000-1C.type" 37*12eb87fbSAlex Wilsonmsgstr "Fault" 38*12eb87fbSAlex Wilsonmsgid "NIC-8000-1C.severity" 39*12eb87fbSAlex Wilsonmsgstr "Critical" 40*12eb87fbSAlex Wilsonmsgid "NIC-8000-1C.description" 41*12eb87fbSAlex Wilsonmsgstr "NIC transceiver module %<fault-list[0].resource.hc-specific.txr_index> (SFP/SFP+/QSFP+ etc.) in %<fault-list[0].resource.hc-specific.link-name> is of a type that is not allowed to be used with this NIC (due to a hardware-enforced vendor or part whitelist).\n\n NIC data link: %<fault-list[0].resource.hc-specific.link-name> (%<fault-list[0].resource.hc-specific.primary-mac-address>)\n Module vendor: %<fault-list[0].resource.hc-specific.vendor>\n Module part: %<fault-list[0].resource.part>\n Module serial: %<fault-list[0].resource.serial>\n\n Refer to %s for more information." 42*12eb87fbSAlex Wilsonmsgid "NIC-8000-1C.response" 43*12eb87fbSAlex Wilsonmsgstr "The transceiver module has been disabled, and the network data link associated with it (%<fault-list[0].resource.hc-specific.link-name>) has been marked as down.\n" 44*12eb87fbSAlex Wilsonmsgid "NIC-8000-1C.impact" 45*12eb87fbSAlex Wilsonmsgstr "No network traffic will pass through the data link or network\ninterfaces associated with this transceiver slot.\n" 46*12eb87fbSAlex Wilsonmsgid "NIC-8000-1C.action" 47*12eb87fbSAlex Wilsonmsgstr "Replace the transceiver module with one of a supported type.\n" 48*12eb87fbSAlex Wilson 49*12eb87fbSAlex Wilson# 50*12eb87fbSAlex Wilson# code: NIC-8000-2R 51*12eb87fbSAlex Wilson# keys: fault.io.nic.transceiver.overtemp 52*12eb87fbSAlex Wilson# 53*12eb87fbSAlex Wilsonmsgid "NIC-8000-2R.type" 54*12eb87fbSAlex Wilsonmsgstr "Fault" 55*12eb87fbSAlex Wilsonmsgid "NIC-8000-2R.severity" 56*12eb87fbSAlex Wilsonmsgstr "Critical" 57*12eb87fbSAlex Wilsonmsgid "NIC-8000-2R.description" 58*12eb87fbSAlex Wilsonmsgstr "NIC transceiver module %<fault-list[0].resource.hc-specific.txr_index> (SFP/SFP+/QSFP+ etc.) in %<fault-list[0].resource.hc-specific.link-name> has overheated.\n\n NIC data link: %<fault-list[0].resource.hc-specific.link-name> (%<fault-list[0].resource.hc-specific.primary-mac-address>)\n Module vendor: %<fault-list[0].resource.hc-specific.vendor>\n Module part: %<fault-list[0].resource.part>\n Module serial: %<fault-list[0].resource.serial>\n\n Refer to %s for more information." 59*12eb87fbSAlex Wilsonmsgid "NIC-8000-2R.response" 60*12eb87fbSAlex Wilsonmsgstr "The transceiver module has been disabled, and the network data link associated with it (%<fault-list[0].resource.hc-specific.link-name>) has been marked as down.\n" 61*12eb87fbSAlex Wilsonmsgid "NIC-8000-2R.impact" 62*12eb87fbSAlex Wilsonmsgstr "No network traffic will pass through the data link or network interfaces associated with this transceiver slot.\n" 63*12eb87fbSAlex Wilsonmsgid "NIC-8000-2R.action" 64*12eb87fbSAlex Wilsonmsgstr "Remove the transceiver module and check for adequate ventilation\nand cooling. Re-inserting the module after it has cooled will restore service.\n" 65*12eb87fbSAlex Wilson 66*12eb87fbSAlex Wilson# 67*12eb87fbSAlex Wilson# code: NIC-8000-34 68*12eb87fbSAlex Wilson# keys: fault.io.nic.transceiver.hwfail 69*12eb87fbSAlex Wilson# 70*12eb87fbSAlex Wilsonmsgid "NIC-8000-34.type" 71*12eb87fbSAlex Wilsonmsgstr "Fault" 72*12eb87fbSAlex Wilsonmsgid "NIC-8000-34.severity" 73*12eb87fbSAlex Wilsonmsgstr "Critical" 74*12eb87fbSAlex Wilsonmsgid "NIC-8000-34.description" 75*12eb87fbSAlex Wilsonmsgstr "NIC transceiver module %<fault-list[0].resource.hc-specific.txr_index> (SFP/SFP+/QSFP+ etc.) in %<fault-list[0].resource.hc-specific.link-name> has experienced a hardware failure.\n\n NIC data link: %<fault-list[0].resource.hc-specific.link-name> (%<fault-list[0].resource.hc-specific.primary-mac-address>)\n Module vendor: %<fault-list[0].resource.hc-specific.vendor>\n Module part: %<fault-list[0].resource.part>\n Module serial: %<fault-list[0].resource.serial>\n\n Refer to %s for more information." 76*12eb87fbSAlex Wilsonmsgid "NIC-8000-34.response" 77*12eb87fbSAlex Wilsonmsgstr "The transceiver module has been disabled, and the network data link associated with it (%<fault-list[0].resource.hc-specific.link-name>) has been marked as down.\n" 78*12eb87fbSAlex Wilsonmsgid "NIC-8000-34.impact" 79*12eb87fbSAlex Wilsonmsgstr "No network traffic will pass through the data link or network\ninterfaces associated with this transceiver slot.\n" 80*12eb87fbSAlex Wilsonmsgid "NIC-8000-34.action" 81*12eb87fbSAlex Wilsonmsgstr "Remove and check the transceiver module, and consider replacing it.\n" 82*12eb87fbSAlex Wilson 83*12eb87fbSAlex Wilson# 84*12eb87fbSAlex Wilson# code: NIC-8000-4X 85*12eb87fbSAlex Wilson# keys: fault.io.nic.transceiver.unknown 86*12eb87fbSAlex Wilson# 87*12eb87fbSAlex Wilsonmsgid "NIC-8000-4X.type" 88*12eb87fbSAlex Wilsonmsgstr "Fault" 89*12eb87fbSAlex Wilsonmsgid "NIC-8000-4X.severity" 90*12eb87fbSAlex Wilsonmsgstr "Critical" 91*12eb87fbSAlex Wilsonmsgid "NIC-8000-4X.description" 92*12eb87fbSAlex Wilsonmsgstr "The slot for NIC transceiver module %<fault-list[0].resource.hc-specific.txr_index> (SFP/SFP+/QSFP+ etc.) in %<fault-list[0].resource.hc-specific.link-name> is occupied, but hardware did not find a valid transceiver in it.\n Refer to %s for more information." 93*12eb87fbSAlex Wilsonmsgid "NIC-8000-4X.response" 94*12eb87fbSAlex Wilsonmsgstr "The transceiver module slot has been disabled, and the network data link associated with it (%<fault-list[0].resource.hc-specific.link-name>) has been marked as down.\n" 95*12eb87fbSAlex Wilsonmsgid "NIC-8000-4X.impact" 96*12eb87fbSAlex Wilsonmsgstr "No network traffic will pass through the data link or network\ninterfaces associated with this transceiver slot.\n" 97*12eb87fbSAlex Wilsonmsgid "NIC-8000-4X.action" 98*12eb87fbSAlex Wilsonmsgstr "Remove and check the transceiver module. It may be faulty,\ninserted incorrectly, or not of the correct type for the slot.\nIf problems persist, consider replacing the module.\n" 99